dc/bin/Debug/logs/SECS/INFO/2023-01/20230110.txt

14561 lines
391 KiB
Plaintext
Raw Normal View History

2023-02-23 11:33:23 +08:00
2023-01-10 10:37:48,375: S1F13 W System Bytes=1
<L [0]
>
.
2023-01-10 10:37:48,664: S1F14 System Bytes=1
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 10:37:49,180: S1F17 W System Bytes=2
2023-01-10 10:37:49,215: S1F18 System Bytes=2
<B [1] [] '' 02 >
.
2023-01-10 10:37:49,718: S1F3 W System Bytes=3
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 10:37:49,759: S1F4 System Bytes=3
<L [10]
<A [24] [eventTimestamp] '2023-01-10T02:34:59.307Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 0 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 10:37:50,272: S6F23 W System Bytes=4
<U1 [1] [RSDC] 0 >
.
2023-01-10 10:37:50,308: S6F24 System Bytes=4
<B [1] [] '' 02 >
.
2023-01-10 10:37:50,810: S2F43 W System Bytes=5
<L [0]
>
.
2023-01-10 10:37:50,857: S6F11 W System Bytes=359
<L [3]
<U4 [1] [] 11 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T02:35:00.402Z' >
<U1 [1] [] 0 >
<U4 [1] [] 0 >
<U4 [1] [] 0 >
<A [24] [] '2023-01-09T15:18:18.071Z' >
<A [24] [] '2023-01-09T15:18:18.071Z' >
>
>
>
>
.
2023-01-10 10:37:50,857: S6F12 W System Bytes=359
<B [1] [ACKC6] '' 00 >
.
2023-01-10 10:37:50,890: S2F44 System Bytes=5
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 10:37:51,394: S2F37 W System Bytes=6
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 10:37:51,445: S2F38 System Bytes=6
<B [1] [] '' 00 >
.
2023-01-10 10:37:51,949: S2F35 W System Bytes=7
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 10:37:51,983: S2F36 System Bytes=7
<B [1] [] '' 00 >
.
2023-01-10 10:37:52,487: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 10:37:52,488: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 10:37:52,537: S2F34 System Bytes=8
<B [1] [DRACK] '' 00 >
.
2023-01-10 10:37:53,040: S5F3 W System Bytes=9
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 10:37:53,579: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 10:37:53,580: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 10:37:53,630: S2F34 System Bytes=10
<B [1] [DRACK] '' 00 >
.
2023-01-10 10:37:54,132: S2F35 W System Bytes=11
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 10:37:54,183: S2F36 System Bytes=11
<B [1] [] '' 00 >
.
2023-01-10 10:37:54,699: S2F37 W System Bytes=12
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 10:37:54,750: S2F38 System Bytes=12
<B [1] [] '' 00 >
.
2023-01-10 10:37:55,253: S5F3 W System Bytes=13
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 10:37:55,807: S2F43 W System Bytes=14
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 10:37:55,843: S2F44 System Bytes=14
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 10:37:56,360: S1F3 W System Bytes=15
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 10:37:56,397: S1F4 System Bytes=15
<L [10]
<A [24] [eventTimestamp] '2023-01-10T02:35:05.951Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 0 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 10:37:56,914: S5F5 W System Bytes=16
<L [0]
>
.
2023-01-10 10:37:56,997: S5F6 System Bytes=16
<L [135]
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4065 >
<A [31] [ALTX] 'CV2: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4067 >
<A [29] [ALTX] 'CV2: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4066 >
<A [29] [ALTX] 'CV2: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4069 >
<A [40] [ALTX] 'CV2: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4068 >
<A [30] [ALTX] 'CV2: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4070 >
<A [20] [ALTX] 'CV2: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4073 >
<A [21] [ALTX] 'CV2: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3004 >
<A [36] [ALTX] 'EDS: Estop left infeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3005 >
<A [38] [ALTX] 'EDS: Estop right infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3006 >
<A [39] [ALTX] 'EDS: Estop right outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3007 >
<A [40] [ALTX] 'EDS: Estop right infeed inside activexxx' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3001 >
<A [25] [ALTX] 'EDS: Estop cabinet active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3002 >
<A [37] [ALTX] 'EDS: Estop left infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4086 >
<A [25] [ALTX] 'CV2: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3003 >
<A [38] [ALTX] 'EDS: Estop left outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3049 >
<A [38] [ALTX] 'EDS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4005 >
<A [43] [ALTX] 'CV2: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3048 >
<A [40] [ALTX] 'EDS: Safety fault feedback Estop circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4004 >
<A [25] [ALTX] 'CV2: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3051 >
<A [22] [ALTX] 'EDS: Error door left 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3050 >
<A [40] [ALTX] 'EDS: Safety fault feedback laser circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4006 >
<A [31] [ALTX] 'CV2: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3053 >
<A [22] [ALTX] 'EDS: Error door left 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4001 >
<A [22] [ALTX] 'CV2: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3052 >
<A [22] [ALTX] 'EDS: Error door left 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3055 >
<A [23] [ALTX] 'EDS: Error door right 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4003 >
<A [38] [ALTX] 'CV2: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3054 >
<A [22] [ALTX] 'EDS: Error door left 4' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4002 >
<A [23] [ALTX] 'CV2: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3041 >
<A [18] [ALTX] 'EDS: Error chiller' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3040 >
<A [28] [ALTX] 'EDS: time out vacuum outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3043 >
<A [26] [ALTX] 'EDS: Error aspiration unit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3042 >
<A [23] [ALTX] 'EDS: Error Flap outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3045 >
<A [29] [ALTX] 'EDS: Error drive align infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3044 >
<A [22] [ALTX] 'EDS: Error flap infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3047 >
<A [32] [ALTX] 'EDS: Error drive conveyor infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3046 >
<A [30] [ALTX] 'EDS: Error drive align outfeed' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4010 >
<A [22] [ALTX] 'CV2: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3064 >
<A [60] [ALTX] 'EDS: laser commisiioning active // automatik mode prohibited' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3065 >
<A [42] [ALTX] 'EDS: Interface downstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3066 >
<A [40] [ALTX] 'EDS: Interface upstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3067 >
<A [31] [ALTX] 'EDS: Interface downstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3068 >
<A [29] [ALTX] 'EDS: Interface upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3069 >
<A [41] [ALTX] 'EDS: gap sensor not free / transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3070 >
<A [20] [ALTX] 'EDS: HMI-PLC Timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3071 >
<A [33] [ALTX] 'EDS: Aligning axis not referenced' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3056 >
<A [23] [ALTX] 'EDS: Error door right 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3057 >
<A [23] [ALTX] 'EDS: Error door right 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3058 >
<A [23] [ALTX] 'EDS: Error door right 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3062 >
<A [33] [ALTX] 'EDS: Error drive conveyor outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3063 >
<A [50] [ALTX] 'EDS: Gripper free with data / glass not in gripper' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3019 >
<A [23] [ALTX] 'EDS: time out gripper 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1066 >
<A [29] [ALTX] 'CV1: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3018 >
<A [23] [ALTX] 'EDS: time out gripper 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1067 >
<A [29] [ALTX] 'CV1: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3017 >
<A [31] [ALTX] 'EDS: time out gripper Aligning2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3016 >
<A [31] [ALTX] 'EDS: time out gripper Aligning1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1065 >
<A [31] [ALTX] 'CV1: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3023 >
<A [30] [ALTX] 'EDS: time out gripper linear 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1070 >
<A [20] [ALTX] 'CV1: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3022 >
<A [23] [ALTX] 'EDS: time out gripper 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3021 >
<A [23] [ALTX] 'EDS: time out gripper 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1068 >
<A [30] [ALTX] 'CV1: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3020 >
<A [21] [ALTX] 'EDS: Fuse chiller NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1069 >
<A [40] [ALTX] 'CV1: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3011 >
<A [16] [ALTX] 'EDS: Laser error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3010 >
<A [31] [ALTX] 'EDS: Estop extern active active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3009 >
<A [41] [ALTX] 'EDS: Estop right outfeed inside activeyyy' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3008 >
<A [37] [ALTX] 'EDS: Estop left outfeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3015 >
<A [29] [ALTX] 'EDS: Fuse cabinet cooling NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3501 >
<A [42] [ALTX] 'EDS: Automatic power measurement requested' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3014 >
<A [31] [ALTX] 'EDS: Overvoltage protection NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3013 >
<A [33] [ALTX] 'EDS: Communication with Laser NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3012 >
<A [34] [ALTX] 'EDS: Fuse Power supply Laser 1 NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3034 >
<A [37] [ALTX] 'EDS: time out conveyor lifting infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3035 >
<A [38] [ALTX] 'EDS: time out conveyor lifting outfeed' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3505 >
<A [52] [ALTX] 'EDS: Laser simulation mode active. No laser emission' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3032 >
<A [28] [ALTX] 'EDS: Fuse 24V peripheral NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3506 >
<A [53] [ALTX] 'EDS: Aspiration settings too low. Beware of pollution' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3033 >
<A [23] [ALTX] 'EDS: Fuse 24V drive NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3038 >
<A [28] [ALTX] 'EDS: process stopped by user' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3039 >
<A [27] [ALTX] 'EDS: time out vacuum infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1086 >
<A [25] [ALTX] 'CV1: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3036 >
<A [30] [ALTX] 'EDS: time out gripper ref glas' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3037 >
<A [36] [ALTX] 'EDS: error air pressure out of range' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3026 >
<A [30] [ALTX] 'EDS: time out gripper linear 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3027 >
<A [34] [ALTX] 'EDS: Fuse 24V Operator buttons NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3024 >
<A [30] [ALTX] 'EDS: air conditioning CA fault' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1073 >
<A [21] [ALTX] 'CV1: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3025 >
<A [30] [ALTX] 'EDS: time out gripper linear 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3030 >
<A [30] [ALTX] 'EDS: time out gripper linear 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3031 >
<A [31] [ALTX] 'EDS: Fuse 24V miscellaneous NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3028 >
<A [24] [ALTX] 'EDS: Fuse supply Asi NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3029 >
<A [21] [ALTX] 'EDS: Fuse 24V IPC NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2065 >
<A [31] [ALTX] 'SBS: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2067 >
<A [29] [ALTX] 'SBS: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2066 >
<A [29] [ALTX] 'SBS: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2069 >
<A [40] [ALTX] 'SBS: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2068 >
<A [30] [ALTX] 'SBS: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2070 >
<A [20] [ALTX] 'SBS: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2073 >
<A [21] [ALTX] 'SBS: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2017 >
<A [19] [ALTX] 'SBS: Error lift low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2016 >
<A [27] [ALTX] 'SBS: Error single centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2019 >
<A [17] [ALTX] 'SBS: Error vacuum' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2018 >
<A [18] [ALTX] 'SBS: Error lift up' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2002 >
<A [23] [ALTX] 'SBS: Estop right active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2003 >
<A [38] [ALTX] 'SBS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2001 >
<A [22] [ALTX] 'SBS: Estop Left active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2006 >
<A [18] [ALTX] 'SBS: Error Brush 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2007 >
<A [18] [ALTX] 'SBS: Error Brush 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2004 >
<A [25] [ALTX] 'SBS: Error conveyor drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2005 >
<A [19] [ALTX] 'SBS: Error Brush 1 ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2010 >
<A [22] [ALTX] 'SBS: Estop line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2008 >
<A [18] [ALTX] 'SBS: Error Brush 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2009 >
<A [35] [ALTX] 'SBS: Error brush 1 linear movement ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2014 >
<A [34] [ALTX] 'SBS: Error brush 4 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2015 >
<A [25] [ALTX] 'SBS: Error dual centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2012 >
<A [34] [ALTX] 'SBS: Error brush 2 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2013 >
<A [34] [ALTX] 'SBS: Error brush 3 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2086 >
<A [25] [ALTX] 'SBS: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1010 >
<A [22] [ALTX] 'CV1: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1001 >
<A [22] [ALTX] 'CV1: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1003 >
<A [38] [ALTX] 'CV1: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1002 >
<A [23] [ALTX] 'CV1: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1005 >
<A [43] [ALTX] 'CV1: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1004 >
<A [25] [ALTX] 'CV1: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1006 >
<A [31] [ALTX] 'CV1: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3072 >
<A [32] [ALTX] 'EDS: Fuse Drives 400V supply NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3073 >
<A [38] [ALTX] 'EDS: SQ stopped by HMI => no PLC error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3074 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 1 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3075 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 2 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3076 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 3 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3077 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 4 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3078 >
<A [45] [ALTX] 'EDS: Aspiration flow ASP too low (upper head)' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3079 >
<A [45] [ALTX] 'EDS: Aspiration flow PHD too low (lower head)' >
>
>
.
2023-01-10 10:37:57,511: S7F19 W System Bytes=17
2023-01-10 10:37:57,548: S7F20 System Bytes=17
<L [8]
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
>
.
2023-01-10 10:37:58,066: S2F13 W System Bytes=0
<L [14]
<U4 [1] [EnableAlarmReportSend] 4 >
<U4 [1] [TimeFormat] 8 >
<U4 [1] [MaxTerminalMsgLength] 9 >
<U4 [1] [EstablishCommunicationsTimeout] 49 >
<U4 [1] [DefaultCommunicationState] 12 >
<U4 [1] [DefaultControlState] 15 >
<U4 [1] [DefaultOnlineSubState] 16 >
<U4 [1] [DefaultOfflineSubState] 17 >
<U4 [1] [EnableSpooling] 40 >
<U4 [1] [OverWriteSpool] 42 >
<U4 [1] [MaxSpoolMessages] 43 >
<U4 [1] [MaxSpoolTransmit] 44 >
<U4 [1] [MDLN] 1 >
<U4 [1] [SOFTREV] 2 >
>
.
2023-01-10 10:37:58,101: S2F14 System Bytes=18
<L [14]
<BOOLEAN [1] [EnableAlarmReportSend] T >
<U1 [1] [TimeFormat] 2 >
<U4 [1] [MaxTerminalMsgLength] 80 >
<I2 [1] [EstablishCommunicationsTimeout] 30 >
<U1 [1] [DefaultCommunicationState] 1 >
<U1 [1] [DefaultControlState] 5 >
<U1 [1] [DefaultOnlineSubState] 5 >
<U1 [1] [DefaultOfflineSubState] 2 >
<BOOLEAN [1] [EnableSpooling] T >
<BOOLEAN [1] [OverWriteSpool] T >
<U4 [1] [MaxSpoolMessages] 100000 >
<U4 [1] [MaxSpoolTransmit] 0 >
<L [0]
>
<L [0]
>
>
.
2023-01-10 10:37:58,609: S2F15 W System Bytes=19
<L [2]
<L [2]
<U4 [1] [DefaultControlState] 15 >
<U1 [1] [ECV] 5 >
>
<L [2]
<U4 [1] [DefaultOnlineSubState] 16 >
<U1 [1] [ECV] 5 >
>
>
.
2023-01-10 10:37:58,655: S2F16 System Bytes=19
<B [1] [] '' 00 >
.
2023-01-10 10:37:59,158: S1F15 W System Bytes=20
2023-01-10 10:37:59,223: S1F16 System Bytes=20
<B [1] [] '' 00 >
.
2023-01-10 10:37:59,224: S6F11 W System Bytes=360
<L [3]
<U4 [1] [] 12 >
<U4 [1] [] 1 >
<L [1]
<L [2]
<U4 [1] [] 1 >
<L [3]
<A [24] [Clock] '2023-01-10T02:35:08.768Z' >
<U1 [1] [CurrentControlState] 3 >
<U1 [1] [PreviousControlState] 5 >
>
>
>
>
.
2023-01-10 10:37:59,225: S6F12 W System Bytes=360
<B [1] [ACKC6] '' 00 >
.
2023-01-10 10:37:59,726: S1F17 W System Bytes=21
2023-01-10 10:37:59,777: S6F11 W System Bytes=361
<L [3]
<U4 [1] [] 13 >
<U4 [1] [] 3 >
<L [1]
<L [2]
<U4 [1] [] 3 >
<L [3]
<A [24] [Clock] '2023-01-10T02:35:09.324Z' >
<U1 [1] [CurrentControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
>
>
>
>
.
2023-01-10 10:37:59,777: S6F12 W System Bytes=361
<B [1] [ACKC6] '' 00 >
.
2023-01-10 10:37:59,777: S1F18 System Bytes=21
<B [1] [] '' 00 >
.
2023-01-10 10:38:00,294: S1F3 W System Bytes=22
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 10:38:00,391: S1F4 System Bytes=22
<L [10]
<A [24] [eventTimestamp] '2023-01-10T02:35:09.884Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 10:38:00,893: S2F23 W System Bytes=23
<L [5]
<U4 [1] [TRID] 1 >
<A [6] [DSPER_hhmmss] '000010' >
<U4 [1] [TOTSMP] 0 >
<U4 [1] [REPGSZ] 1 >
<L [0]
>
>
.
2023-01-10 10:38:00,943: S2F24 System Bytes=23
<B [1] [] '' 00 >
.
2023-01-10 11:03:27,144: S1F13 W System Bytes=1
<L [0]
>
.
2023-01-10 11:03:27,450: S1F14 System Bytes=1
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:03:27,959: S1F17 W System Bytes=2
2023-01-10 11:03:27,994: S1F18 System Bytes=2
<B [1] [] '' 02 >
.
2023-01-10 11:03:28,506: S1F3 W System Bytes=3
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:03:28,543: S1F4 System Bytes=3
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:00:38.084Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 1 >
<U4 [1] [SpoolCountActual] 2 >
<U4 [1] [SpoolCountTotal] 2 >
>
.
2023-01-10 11:03:29,053: S6F23 W System Bytes=4
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:03:29,090: S6F24 System Bytes=4
<B [1] [] '' 00 >
.
2023-01-10 11:03:29,205: S6F11 W System Bytes=427
<L [3]
<U4 [1] [] 29 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:00:38.747Z' >
<U1 [1] [] 0 >
<U4 [1] [] 2 >
<U4 [1] [] 2 >
<A [24] [] '2023-01-10T02:35:00.400Z' >
<A [24] [] '2023-01-10T03:00:15.821Z' >
>
>
>
>
.
2023-01-10 11:03:29,205: S6F12 W System Bytes=427
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:03:29,207: S2F43 W System Bytes=5
<L [0]
>
.
2023-01-10 11:03:29,278: S6F11 W System Bytes=428
<L [3]
<U4 [1] [] 30 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:00:38.832Z' >
<U1 [1] [] 0 >
<U4 [1] [] 2 >
<U4 [1] [] 2 >
<A [24] [] '2023-01-10T02:35:00.400Z' >
<A [24] [] '2023-01-10T03:00:15.821Z' >
>
>
>
>
.
2023-01-10 11:03:29,279: S6F12 W System Bytes=428
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:03:29,315: S2F44 System Bytes=5
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:03:29,826: S2F37 W System Bytes=6
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:03:29,876: S2F38 System Bytes=6
<B [1] [] '' 00 >
.
2023-01-10 11:03:30,390: S2F35 W System Bytes=7
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:03:30,420: S2F36 System Bytes=7
<B [1] [] '' 00 >
.
2023-01-10 11:03:30,930: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:03:30,931: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:03:30,979: S2F34 System Bytes=8
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:03:31,492: S5F3 W System Bytes=9
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:03:32,037: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:03:32,038: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:03:32,087: S2F34 System Bytes=10
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:03:32,597: S2F35 W System Bytes=11
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 11:03:32,651: S2F36 System Bytes=11
<B [1] [] '' 00 >
.
2023-01-10 11:03:33,153: S2F37 W System Bytes=12
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 11:03:33,203: S2F38 System Bytes=12
<B [1] [] '' 00 >
.
2023-01-10 11:03:33,717: S5F3 W System Bytes=13
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:03:34,278: S2F43 W System Bytes=14
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 11:03:34,316: S2F44 System Bytes=14
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:03:34,822: S1F3 W System Bytes=15
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:03:34,874: S1F4 System Bytes=15
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:00:44.400Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:03:35,380: S5F5 W System Bytes=16
<L [0]
>
.
2023-01-10 11:03:35,433: S5F6 System Bytes=16
<L [135]
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4065 >
<A [31] [ALTX] 'CV2: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4067 >
<A [29] [ALTX] 'CV2: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4066 >
<A [29] [ALTX] 'CV2: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4069 >
<A [40] [ALTX] 'CV2: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4068 >
<A [30] [ALTX] 'CV2: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4070 >
<A [20] [ALTX] 'CV2: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4073 >
<A [21] [ALTX] 'CV2: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3004 >
<A [36] [ALTX] 'EDS: Estop left infeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3005 >
<A [38] [ALTX] 'EDS: Estop right infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3006 >
<A [39] [ALTX] 'EDS: Estop right outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3007 >
<A [40] [ALTX] 'EDS: Estop right infeed inside activexxx' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3001 >
<A [25] [ALTX] 'EDS: Estop cabinet active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3002 >
<A [37] [ALTX] 'EDS: Estop left infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4086 >
<A [25] [ALTX] 'CV2: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3003 >
<A [38] [ALTX] 'EDS: Estop left outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3049 >
<A [38] [ALTX] 'EDS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4005 >
<A [43] [ALTX] 'CV2: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3048 >
<A [40] [ALTX] 'EDS: Safety fault feedback Estop circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4004 >
<A [25] [ALTX] 'CV2: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3051 >
<A [22] [ALTX] 'EDS: Error door left 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3050 >
<A [40] [ALTX] 'EDS: Safety fault feedback laser circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4006 >
<A [31] [ALTX] 'CV2: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3053 >
<A [22] [ALTX] 'EDS: Error door left 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4001 >
<A [22] [ALTX] 'CV2: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3052 >
<A [22] [ALTX] 'EDS: Error door left 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3055 >
<A [23] [ALTX] 'EDS: Error door right 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4003 >
<A [38] [ALTX] 'CV2: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3054 >
<A [22] [ALTX] 'EDS: Error door left 4' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4002 >
<A [23] [ALTX] 'CV2: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3041 >
<A [18] [ALTX] 'EDS: Error chiller' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3040 >
<A [28] [ALTX] 'EDS: time out vacuum outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3043 >
<A [26] [ALTX] 'EDS: Error aspiration unit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3042 >
<A [23] [ALTX] 'EDS: Error Flap outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3045 >
<A [29] [ALTX] 'EDS: Error drive align infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3044 >
<A [22] [ALTX] 'EDS: Error flap infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3047 >
<A [32] [ALTX] 'EDS: Error drive conveyor infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3046 >
<A [30] [ALTX] 'EDS: Error drive align outfeed' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4010 >
<A [22] [ALTX] 'CV2: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3064 >
<A [60] [ALTX] 'EDS: laser commisiioning active // automatik mode prohibited' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3065 >
<A [42] [ALTX] 'EDS: Interface downstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3066 >
<A [40] [ALTX] 'EDS: Interface upstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3067 >
<A [31] [ALTX] 'EDS: Interface downstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3068 >
<A [29] [ALTX] 'EDS: Interface upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3069 >
<A [41] [ALTX] 'EDS: gap sensor not free / transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3070 >
<A [20] [ALTX] 'EDS: HMI-PLC Timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3071 >
<A [33] [ALTX] 'EDS: Aligning axis not referenced' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3056 >
<A [23] [ALTX] 'EDS: Error door right 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3057 >
<A [23] [ALTX] 'EDS: Error door right 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3058 >
<A [23] [ALTX] 'EDS: Error door right 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3062 >
<A [33] [ALTX] 'EDS: Error drive conveyor outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3063 >
<A [50] [ALTX] 'EDS: Gripper free with data / glass not in gripper' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3019 >
<A [23] [ALTX] 'EDS: time out gripper 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1066 >
<A [29] [ALTX] 'CV1: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3018 >
<A [23] [ALTX] 'EDS: time out gripper 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1067 >
<A [29] [ALTX] 'CV1: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3017 >
<A [31] [ALTX] 'EDS: time out gripper Aligning2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3016 >
<A [31] [ALTX] 'EDS: time out gripper Aligning1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1065 >
<A [31] [ALTX] 'CV1: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3023 >
<A [30] [ALTX] 'EDS: time out gripper linear 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1070 >
<A [20] [ALTX] 'CV1: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3022 >
<A [23] [ALTX] 'EDS: time out gripper 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3021 >
<A [23] [ALTX] 'EDS: time out gripper 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1068 >
<A [30] [ALTX] 'CV1: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3020 >
<A [21] [ALTX] 'EDS: Fuse chiller NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1069 >
<A [40] [ALTX] 'CV1: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3011 >
<A [16] [ALTX] 'EDS: Laser error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3010 >
<A [31] [ALTX] 'EDS: Estop extern active active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3009 >
<A [41] [ALTX] 'EDS: Estop right outfeed inside activeyyy' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3008 >
<A [37] [ALTX] 'EDS: Estop left outfeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3015 >
<A [29] [ALTX] 'EDS: Fuse cabinet cooling NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3501 >
<A [42] [ALTX] 'EDS: Automatic power measurement requested' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3014 >
<A [31] [ALTX] 'EDS: Overvoltage protection NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3013 >
<A [33] [ALTX] 'EDS: Communication with Laser NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3012 >
<A [34] [ALTX] 'EDS: Fuse Power supply Laser 1 NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3034 >
<A [37] [ALTX] 'EDS: time out conveyor lifting infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3035 >
<A [38] [ALTX] 'EDS: time out conveyor lifting outfeed' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3505 >
<A [52] [ALTX] 'EDS: Laser simulation mode active. No laser emission' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3032 >
<A [28] [ALTX] 'EDS: Fuse 24V peripheral NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3506 >
<A [53] [ALTX] 'EDS: Aspiration settings too low. Beware of pollution' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3033 >
<A [23] [ALTX] 'EDS: Fuse 24V drive NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3038 >
<A [28] [ALTX] 'EDS: process stopped by user' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3039 >
<A [27] [ALTX] 'EDS: time out vacuum infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1086 >
<A [25] [ALTX] 'CV1: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3036 >
<A [30] [ALTX] 'EDS: time out gripper ref glas' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3037 >
<A [36] [ALTX] 'EDS: error air pressure out of range' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3026 >
<A [30] [ALTX] 'EDS: time out gripper linear 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3027 >
<A [34] [ALTX] 'EDS: Fuse 24V Operator buttons NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3024 >
<A [30] [ALTX] 'EDS: air conditioning CA fault' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1073 >
<A [21] [ALTX] 'CV1: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3025 >
<A [30] [ALTX] 'EDS: time out gripper linear 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3030 >
<A [30] [ALTX] 'EDS: time out gripper linear 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3031 >
<A [31] [ALTX] 'EDS: Fuse 24V miscellaneous NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3028 >
<A [24] [ALTX] 'EDS: Fuse supply Asi NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3029 >
<A [21] [ALTX] 'EDS: Fuse 24V IPC NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2065 >
<A [31] [ALTX] 'SBS: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2067 >
<A [29] [ALTX] 'SBS: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2066 >
<A [29] [ALTX] 'SBS: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2069 >
<A [40] [ALTX] 'SBS: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2068 >
<A [30] [ALTX] 'SBS: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2070 >
<A [20] [ALTX] 'SBS: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2073 >
<A [21] [ALTX] 'SBS: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2017 >
<A [19] [ALTX] 'SBS: Error lift low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2016 >
<A [27] [ALTX] 'SBS: Error single centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2019 >
<A [17] [ALTX] 'SBS: Error vacuum' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2018 >
<A [18] [ALTX] 'SBS: Error lift up' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2002 >
<A [23] [ALTX] 'SBS: Estop right active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2003 >
<A [38] [ALTX] 'SBS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2001 >
<A [22] [ALTX] 'SBS: Estop Left active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2006 >
<A [18] [ALTX] 'SBS: Error Brush 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2007 >
<A [18] [ALTX] 'SBS: Error Brush 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2004 >
<A [25] [ALTX] 'SBS: Error conveyor drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2005 >
<A [19] [ALTX] 'SBS: Error Brush 1 ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2010 >
<A [22] [ALTX] 'SBS: Estop line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2008 >
<A [18] [ALTX] 'SBS: Error Brush 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2009 >
<A [35] [ALTX] 'SBS: Error brush 1 linear movement ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2014 >
<A [34] [ALTX] 'SBS: Error brush 4 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2015 >
<A [25] [ALTX] 'SBS: Error dual centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2012 >
<A [34] [ALTX] 'SBS: Error brush 2 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2013 >
<A [34] [ALTX] 'SBS: Error brush 3 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2086 >
<A [25] [ALTX] 'SBS: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1010 >
<A [22] [ALTX] 'CV1: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1001 >
<A [22] [ALTX] 'CV1: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1003 >
<A [38] [ALTX] 'CV1: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1002 >
<A [23] [ALTX] 'CV1: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1005 >
<A [43] [ALTX] 'CV1: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1004 >
<A [25] [ALTX] 'CV1: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1006 >
<A [31] [ALTX] 'CV1: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3072 >
<A [32] [ALTX] 'EDS: Fuse Drives 400V supply NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3073 >
<A [38] [ALTX] 'EDS: SQ stopped by HMI => no PLC error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3074 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 1 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3075 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 2 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3076 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 3 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3077 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 4 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3078 >
<A [45] [ALTX] 'EDS: Aspiration flow ASP too low (upper head)' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3079 >
<A [45] [ALTX] 'EDS: Aspiration flow PHD too low (lower head)' >
>
>
.
2023-01-10 11:03:35,942: S7F19 W System Bytes=17
2023-01-10 11:03:35,978: S7F20 System Bytes=17
<L [8]
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
>
.
2023-01-10 11:03:36,485: S2F13 W System Bytes=0
<L [14]
<U4 [1] [EnableAlarmReportSend] 4 >
<U4 [1] [TimeFormat] 8 >
<U4 [1] [MaxTerminalMsgLength] 9 >
<U4 [1] [EstablishCommunicationsTimeout] 49 >
<U4 [1] [DefaultCommunicationState] 12 >
<U4 [1] [DefaultControlState] 15 >
<U4 [1] [DefaultOnlineSubState] 16 >
<U4 [1] [DefaultOfflineSubState] 17 >
<U4 [1] [EnableSpooling] 40 >
<U4 [1] [OverWriteSpool] 42 >
<U4 [1] [MaxSpoolMessages] 43 >
<U4 [1] [MaxSpoolTransmit] 44 >
<U4 [1] [MDLN] 1 >
<U4 [1] [SOFTREV] 2 >
>
.
2023-01-10 11:03:36,538: S2F14 System Bytes=18
<L [14]
<BOOLEAN [1] [EnableAlarmReportSend] T >
<U1 [1] [TimeFormat] 2 >
<U4 [1] [MaxTerminalMsgLength] 80 >
<I2 [1] [EstablishCommunicationsTimeout] 30 >
<U1 [1] [DefaultCommunicationState] 1 >
<U1 [1] [DefaultControlState] 5 >
<U1 [1] [DefaultOnlineSubState] 5 >
<U1 [1] [DefaultOfflineSubState] 2 >
<BOOLEAN [1] [EnableSpooling] T >
<BOOLEAN [1] [OverWriteSpool] T >
<U4 [1] [MaxSpoolMessages] 100000 >
<U4 [1] [MaxSpoolTransmit] 0 >
<L [0]
>
<L [0]
>
>
.
2023-01-10 11:03:37,048: S2F15 W System Bytes=19
<L [2]
<L [2]
<U4 [1] [DefaultControlState] 15 >
<U1 [1] [ECV] 5 >
>
<L [2]
<U4 [1] [DefaultOnlineSubState] 16 >
<U1 [1] [ECV] 5 >
>
>
.
2023-01-10 11:03:37,080: S2F16 System Bytes=19
<B [1] [] '' 00 >
.
2023-01-10 11:03:37,595: S1F15 W System Bytes=20
2023-01-10 11:03:37,631: S1F16 System Bytes=20
<B [1] [] '' 00 >
.
2023-01-10 11:03:37,632: S6F11 W System Bytes=429
<L [3]
<U4 [1] [] 31 >
<U4 [1] [] 1 >
<L [1]
<L [2]
<U4 [1] [] 1 >
<L [3]
<A [24] [Clock] '2023-01-10T03:00:47.175Z' >
<U1 [1] [CurrentControlState] 3 >
<U1 [1] [PreviousControlState] 5 >
>
>
>
>
.
2023-01-10 11:03:37,632: S6F12 W System Bytes=429
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:03:38,140: S1F17 W System Bytes=21
2023-01-10 11:03:38,175: S6F11 W System Bytes=430
<L [3]
<U4 [1] [] 32 >
<U4 [1] [] 3 >
<L [1]
<L [2]
<U4 [1] [] 3 >
<L [3]
<A [24] [Clock] '2023-01-10T03:00:47.719Z' >
<U1 [1] [CurrentControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
>
>
>
>
.
2023-01-10 11:03:38,178: S6F12 W System Bytes=430
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:03:38,178: S1F18 System Bytes=21
<B [1] [] '' 00 >
.
2023-01-10 11:03:38,697: S1F3 W System Bytes=22
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:03:38,733: S1F4 System Bytes=22
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:00:48.275Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:03:39,247: S2F23 W System Bytes=23
<L [5]
<U4 [1] [TRID] 1 >
<A [6] [DSPER_hhmmss] '000010' >
<U4 [1] [TOTSMP] 0 >
<U4 [1] [REPGSZ] 1 >
<L [0]
>
>
.
2023-01-10 11:03:39,280: S2F24 System Bytes=23
<B [1] [] '' 00 >
.
2023-01-10 11:08:21,141: S1F13 W System Bytes=1
<L [0]
>
.
2023-01-10 11:08:21,421: S1F14 System Bytes=1
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:08:21,927: S1F17 W System Bytes=2
2023-01-10 11:08:21,962: S1F18 System Bytes=2
<B [1] [] '' 02 >
.
2023-01-10 11:08:22,471: S1F3 W System Bytes=3
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:08:22,505: S1F4 System Bytes=3
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:05:32.046Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 1 >
<U4 [1] [SpoolCountActual] 1 >
<U4 [1] [SpoolCountTotal] 1 >
>
.
2023-01-10 11:08:23,012: S6F23 W System Bytes=4
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:08:23,047: S6F24 System Bytes=4
<B [1] [] '' 00 >
.
2023-01-10 11:08:23,132: S6F11 W System Bytes=451
<L [3]
<U4 [1] [] 43 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:05:32.680Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:00:38.830Z' >
<A [24] [] '2023-01-10T03:05:09.926Z' >
>
>
>
>
.
2023-01-10 11:08:23,132: S6F12 W System Bytes=451
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:08:23,135: S2F43 W System Bytes=5
<L [0]
>
.
2023-01-10 11:08:23,206: S6F11 W System Bytes=452
<L [3]
<U4 [1] [] 44 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:05:32.754Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:00:38.830Z' >
<A [24] [] '2023-01-10T03:05:09.926Z' >
>
>
>
>
.
2023-01-10 11:08:23,207: S6F12 W System Bytes=452
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:08:23,242: S2F44 System Bytes=5
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:08:23,753: S2F37 W System Bytes=6
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:08:23,799: S2F38 System Bytes=6
<B [1] [] '' 00 >
.
2023-01-10 11:08:24,308: S2F35 W System Bytes=7
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:08:24,343: S2F36 System Bytes=7
<B [1] [] '' 00 >
.
2023-01-10 11:08:24,855: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:08:24,855: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:08:24,904: S2F34 System Bytes=8
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:08:25,417: S5F3 W System Bytes=9
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:08:25,969: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:08:25,970: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:08:26,012: S2F34 System Bytes=10
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:08:26,520: S2F35 W System Bytes=11
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 11:08:26,568: S2F36 System Bytes=11
<B [1] [] '' 00 >
.
2023-01-10 11:08:27,081: S2F37 W System Bytes=12
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 11:08:27,131: S2F38 System Bytes=12
<B [1] [] '' 00 >
.
2023-01-10 11:08:27,640: S5F3 W System Bytes=13
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:08:28,204: S2F43 W System Bytes=14
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 11:08:28,235: S2F44 System Bytes=14
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:08:28,744: S1F3 W System Bytes=15
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:08:28,779: S1F4 System Bytes=15
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:05:38.320Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:08:29,294: S5F5 W System Bytes=16
<L [0]
>
.
2023-01-10 11:08:29,347: S5F6 System Bytes=16
<L [135]
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4065 >
<A [31] [ALTX] 'CV2: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4067 >
<A [29] [ALTX] 'CV2: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4066 >
<A [29] [ALTX] 'CV2: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4069 >
<A [40] [ALTX] 'CV2: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4068 >
<A [30] [ALTX] 'CV2: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4070 >
<A [20] [ALTX] 'CV2: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4073 >
<A [21] [ALTX] 'CV2: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3004 >
<A [36] [ALTX] 'EDS: Estop left infeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3005 >
<A [38] [ALTX] 'EDS: Estop right infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3006 >
<A [39] [ALTX] 'EDS: Estop right outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3007 >
<A [40] [ALTX] 'EDS: Estop right infeed inside activexxx' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3001 >
<A [25] [ALTX] 'EDS: Estop cabinet active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3002 >
<A [37] [ALTX] 'EDS: Estop left infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4086 >
<A [25] [ALTX] 'CV2: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3003 >
<A [38] [ALTX] 'EDS: Estop left outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3049 >
<A [38] [ALTX] 'EDS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4005 >
<A [43] [ALTX] 'CV2: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3048 >
<A [40] [ALTX] 'EDS: Safety fault feedback Estop circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4004 >
<A [25] [ALTX] 'CV2: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3051 >
<A [22] [ALTX] 'EDS: Error door left 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3050 >
<A [40] [ALTX] 'EDS: Safety fault feedback laser circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4006 >
<A [31] [ALTX] 'CV2: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3053 >
<A [22] [ALTX] 'EDS: Error door left 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4001 >
<A [22] [ALTX] 'CV2: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3052 >
<A [22] [ALTX] 'EDS: Error door left 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3055 >
<A [23] [ALTX] 'EDS: Error door right 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4003 >
<A [38] [ALTX] 'CV2: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3054 >
<A [22] [ALTX] 'EDS: Error door left 4' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4002 >
<A [23] [ALTX] 'CV2: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3041 >
<A [18] [ALTX] 'EDS: Error chiller' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3040 >
<A [28] [ALTX] 'EDS: time out vacuum outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3043 >
<A [26] [ALTX] 'EDS: Error aspiration unit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3042 >
<A [23] [ALTX] 'EDS: Error Flap outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3045 >
<A [29] [ALTX] 'EDS: Error drive align infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3044 >
<A [22] [ALTX] 'EDS: Error flap infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3047 >
<A [32] [ALTX] 'EDS: Error drive conveyor infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3046 >
<A [30] [ALTX] 'EDS: Error drive align outfeed' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4010 >
<A [22] [ALTX] 'CV2: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3064 >
<A [60] [ALTX] 'EDS: laser commisiioning active // automatik mode prohibited' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3065 >
<A [42] [ALTX] 'EDS: Interface downstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3066 >
<A [40] [ALTX] 'EDS: Interface upstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3067 >
<A [31] [ALTX] 'EDS: Interface downstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3068 >
<A [29] [ALTX] 'EDS: Interface upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3069 >
<A [41] [ALTX] 'EDS: gap sensor not free / transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3070 >
<A [20] [ALTX] 'EDS: HMI-PLC Timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3071 >
<A [33] [ALTX] 'EDS: Aligning axis not referenced' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3056 >
<A [23] [ALTX] 'EDS: Error door right 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3057 >
<A [23] [ALTX] 'EDS: Error door right 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3058 >
<A [23] [ALTX] 'EDS: Error door right 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3062 >
<A [33] [ALTX] 'EDS: Error drive conveyor outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3063 >
<A [50] [ALTX] 'EDS: Gripper free with data / glass not in gripper' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3019 >
<A [23] [ALTX] 'EDS: time out gripper 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1066 >
<A [29] [ALTX] 'CV1: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3018 >
<A [23] [ALTX] 'EDS: time out gripper 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1067 >
<A [29] [ALTX] 'CV1: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3017 >
<A [31] [ALTX] 'EDS: time out gripper Aligning2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3016 >
<A [31] [ALTX] 'EDS: time out gripper Aligning1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1065 >
<A [31] [ALTX] 'CV1: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3023 >
<A [30] [ALTX] 'EDS: time out gripper linear 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1070 >
<A [20] [ALTX] 'CV1: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3022 >
<A [23] [ALTX] 'EDS: time out gripper 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3021 >
<A [23] [ALTX] 'EDS: time out gripper 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1068 >
<A [30] [ALTX] 'CV1: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3020 >
<A [21] [ALTX] 'EDS: Fuse chiller NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1069 >
<A [40] [ALTX] 'CV1: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3011 >
<A [16] [ALTX] 'EDS: Laser error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3010 >
<A [31] [ALTX] 'EDS: Estop extern active active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3009 >
<A [41] [ALTX] 'EDS: Estop right outfeed inside activeyyy' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3008 >
<A [37] [ALTX] 'EDS: Estop left outfeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3015 >
<A [29] [ALTX] 'EDS: Fuse cabinet cooling NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3501 >
<A [42] [ALTX] 'EDS: Automatic power measurement requested' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3014 >
<A [31] [ALTX] 'EDS: Overvoltage protection NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3013 >
<A [33] [ALTX] 'EDS: Communication with Laser NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3012 >
<A [34] [ALTX] 'EDS: Fuse Power supply Laser 1 NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3034 >
<A [37] [ALTX] 'EDS: time out conveyor lifting infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3035 >
<A [38] [ALTX] 'EDS: time out conveyor lifting outfeed' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3505 >
<A [52] [ALTX] 'EDS: Laser simulation mode active. No laser emission' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3032 >
<A [28] [ALTX] 'EDS: Fuse 24V peripheral NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3506 >
<A [53] [ALTX] 'EDS: Aspiration settings too low. Beware of pollution' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3033 >
<A [23] [ALTX] 'EDS: Fuse 24V drive NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3038 >
<A [28] [ALTX] 'EDS: process stopped by user' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3039 >
<A [27] [ALTX] 'EDS: time out vacuum infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1086 >
<A [25] [ALTX] 'CV1: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3036 >
<A [30] [ALTX] 'EDS: time out gripper ref glas' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3037 >
<A [36] [ALTX] 'EDS: error air pressure out of range' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3026 >
<A [30] [ALTX] 'EDS: time out gripper linear 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3027 >
<A [34] [ALTX] 'EDS: Fuse 24V Operator buttons NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3024 >
<A [30] [ALTX] 'EDS: air conditioning CA fault' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1073 >
<A [21] [ALTX] 'CV1: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3025 >
<A [30] [ALTX] 'EDS: time out gripper linear 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3030 >
<A [30] [ALTX] 'EDS: time out gripper linear 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3031 >
<A [31] [ALTX] 'EDS: Fuse 24V miscellaneous NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3028 >
<A [24] [ALTX] 'EDS: Fuse supply Asi NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3029 >
<A [21] [ALTX] 'EDS: Fuse 24V IPC NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2065 >
<A [31] [ALTX] 'SBS: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2067 >
<A [29] [ALTX] 'SBS: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2066 >
<A [29] [ALTX] 'SBS: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2069 >
<A [40] [ALTX] 'SBS: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2068 >
<A [30] [ALTX] 'SBS: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2070 >
<A [20] [ALTX] 'SBS: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2073 >
<A [21] [ALTX] 'SBS: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2017 >
<A [19] [ALTX] 'SBS: Error lift low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2016 >
<A [27] [ALTX] 'SBS: Error single centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2019 >
<A [17] [ALTX] 'SBS: Error vacuum' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2018 >
<A [18] [ALTX] 'SBS: Error lift up' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2002 >
<A [23] [ALTX] 'SBS: Estop right active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2003 >
<A [38] [ALTX] 'SBS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2001 >
<A [22] [ALTX] 'SBS: Estop Left active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2006 >
<A [18] [ALTX] 'SBS: Error Brush 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2007 >
<A [18] [ALTX] 'SBS: Error Brush 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2004 >
<A [25] [ALTX] 'SBS: Error conveyor drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2005 >
<A [19] [ALTX] 'SBS: Error Brush 1 ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2010 >
<A [22] [ALTX] 'SBS: Estop line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2008 >
<A [18] [ALTX] 'SBS: Error Brush 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2009 >
<A [35] [ALTX] 'SBS: Error brush 1 linear movement ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2014 >
<A [34] [ALTX] 'SBS: Error brush 4 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2015 >
<A [25] [ALTX] 'SBS: Error dual centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2012 >
<A [34] [ALTX] 'SBS: Error brush 2 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2013 >
<A [34] [ALTX] 'SBS: Error brush 3 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2086 >
<A [25] [ALTX] 'SBS: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1010 >
<A [22] [ALTX] 'CV1: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1001 >
<A [22] [ALTX] 'CV1: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1003 >
<A [38] [ALTX] 'CV1: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1002 >
<A [23] [ALTX] 'CV1: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1005 >
<A [43] [ALTX] 'CV1: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1004 >
<A [25] [ALTX] 'CV1: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1006 >
<A [31] [ALTX] 'CV1: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3072 >
<A [32] [ALTX] 'EDS: Fuse Drives 400V supply NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3073 >
<A [38] [ALTX] 'EDS: SQ stopped by HMI => no PLC error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3074 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 1 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3075 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 2 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3076 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 3 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3077 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 4 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3078 >
<A [45] [ALTX] 'EDS: Aspiration flow ASP too low (upper head)' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3079 >
<A [45] [ALTX] 'EDS: Aspiration flow PHD too low (lower head)' >
>
>
.
2023-01-10 11:08:29,858: S7F19 W System Bytes=17
2023-01-10 11:08:29,894: S7F20 System Bytes=17
<L [8]
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
>
.
2023-01-10 11:08:30,402: S2F13 W System Bytes=0
<L [14]
<U4 [1] [EnableAlarmReportSend] 4 >
<U4 [1] [TimeFormat] 8 >
<U4 [1] [MaxTerminalMsgLength] 9 >
<U4 [1] [EstablishCommunicationsTimeout] 49 >
<U4 [1] [DefaultCommunicationState] 12 >
<U4 [1] [DefaultControlState] 15 >
<U4 [1] [DefaultOnlineSubState] 16 >
<U4 [1] [DefaultOfflineSubState] 17 >
<U4 [1] [EnableSpooling] 40 >
<U4 [1] [OverWriteSpool] 42 >
<U4 [1] [MaxSpoolMessages] 43 >
<U4 [1] [MaxSpoolTransmit] 44 >
<U4 [1] [MDLN] 1 >
<U4 [1] [SOFTREV] 2 >
>
.
2023-01-10 11:08:30,440: S2F14 System Bytes=18
<L [14]
<BOOLEAN [1] [EnableAlarmReportSend] T >
<U1 [1] [TimeFormat] 2 >
<U4 [1] [MaxTerminalMsgLength] 80 >
<I2 [1] [EstablishCommunicationsTimeout] 30 >
<U1 [1] [DefaultCommunicationState] 1 >
<U1 [1] [DefaultControlState] 5 >
<U1 [1] [DefaultOnlineSubState] 5 >
<U1 [1] [DefaultOfflineSubState] 2 >
<BOOLEAN [1] [EnableSpooling] T >
<BOOLEAN [1] [OverWriteSpool] T >
<U4 [1] [MaxSpoolMessages] 100000 >
<U4 [1] [MaxSpoolTransmit] 0 >
<L [0]
>
<L [0]
>
>
.
2023-01-10 11:08:30,952: S2F15 W System Bytes=19
<L [2]
<L [2]
<U4 [1] [DefaultControlState] 15 >
<U1 [1] [ECV] 5 >
>
<L [2]
<U4 [1] [DefaultOnlineSubState] 16 >
<U1 [1] [ECV] 5 >
>
>
.
2023-01-10 11:08:30,989: S2F16 System Bytes=19
<B [1] [] '' 00 >
.
2023-01-10 11:08:31,494: S1F15 W System Bytes=20
2023-01-10 11:08:31,528: S1F16 System Bytes=20
<B [1] [] '' 00 >
.
2023-01-10 11:08:31,529: S6F11 W System Bytes=453
<L [3]
<U4 [1] [] 45 >
<U4 [1] [] 1 >
<L [1]
<L [2]
<U4 [1] [] 1 >
<L [3]
<A [24] [Clock] '2023-01-10T03:05:41.070Z' >
<U1 [1] [CurrentControlState] 3 >
<U1 [1] [PreviousControlState] 5 >
>
>
>
>
.
2023-01-10 11:08:31,529: S6F12 W System Bytes=453
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:08:32,034: S1F17 W System Bytes=21
2023-01-10 11:08:32,070: S6F11 W System Bytes=454
<L [3]
<U4 [1] [] 46 >
<U4 [1] [] 3 >
<L [1]
<L [2]
<U4 [1] [] 3 >
<L [3]
<A [24] [Clock] '2023-01-10T03:05:41.611Z' >
<U1 [1] [CurrentControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
>
>
>
>
.
2023-01-10 11:08:32,073: S1F18 System Bytes=21
<B [1] [] '' 00 >
.
2023-01-10 11:08:32,073: S6F12 W System Bytes=454
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:08:32,581: S1F3 W System Bytes=22
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:08:32,623: S1F4 System Bytes=22
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:05:42.158Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 4000 >
<I2 [1] [PreviousEquipmentState] 4000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:08:33,145: S2F23 W System Bytes=23
<L [5]
<U4 [1] [TRID] 1 >
<A [6] [DSPER_hhmmss] '000010' >
<U4 [1] [TOTSMP] 0 >
<U4 [1] [REPGSZ] 1 >
<L [0]
>
>
.
2023-01-10 11:08:33,174: S2F24 System Bytes=23
<B [1] [] '' 00 >
.
2023-01-10 11:10:33,924: S6F11 W System Bytes=461
<L [3]
<U4 [1] [] 49 >
<U4 [1] [] 300061 >
<L [1]
<L [2]
<U4 [1] [] 200061 >
<L [3]
<A [24] [Clock] '2023-01-10T03:07:43.458Z' >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
>
>
>
>
.
2023-01-10 11:10:33,924: S6F12 W System Bytes=461
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:10:33,952: S6F11 W System Bytes=462
<L [3]
<U4 [1] [] 50 >
<U4 [1] [] 300061 >
<L [1]
<L [2]
<U4 [1] [] 200061 >
<L [3]
<A [24] [Clock] '2023-01-10T03:07:43.461Z' >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
>
>
>
>
.
2023-01-10 11:10:33,953: S6F12 W System Bytes=462
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:10:44,376: S6F11 W System Bytes=463
<L [3]
<U4 [1] [] 51 >
<U4 [1] [] 300011 >
<L [1]
<L [2]
<U4 [1] [] 200011 >
<L [5]
<A [24] [Clock] '2023-01-10T03:07:53.916Z' >
<A [17] [SubstrateID] 'a2023010903310702' >
<A [4] [LocationID] 'LEDE' >
<A [0] [PPExecName] '' >
<BOOLEAN [1] [MaterialStatus] F >
>
>
>
>
.
2023-01-10 11:10:44,376: S6F12 W System Bytes=463
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:11:11,333: S1F13 W System Bytes=24
<L [0]
>
.
2023-01-10 11:11:11,614: S1F14 System Bytes=24
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:11:12,121: S1F17 W System Bytes=25
2023-01-10 11:11:12,155: S1F18 System Bytes=25
<B [1] [] '' 02 >
.
2023-01-10 11:11:12,665: S1F3 W System Bytes=26
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:11:12,702: S1F4 System Bytes=26
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:08:22.240Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 1 >
<U4 [1] [SpoolCountActual] 1 >
<U4 [1] [SpoolCountTotal] 1 >
>
.
2023-01-10 11:11:13,212: S6F23 W System Bytes=27
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:11:13,247: S6F24 System Bytes=27
<B [1] [] '' 00 >
.
2023-01-10 11:11:13,347: S6F11 W System Bytes=468
<L [3]
<U4 [1] [] 53 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:08:22.883Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:05:32.752Z' >
<A [24] [] '2023-01-10T03:08:10.606Z' >
>
>
>
>
.
2023-01-10 11:11:13,348: S6F12 W System Bytes=468
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:11:13,349: S2F43 W System Bytes=28
<L [0]
>
.
2023-01-10 11:11:13,423: S6F11 W System Bytes=469
<L [3]
<U4 [1] [] 54 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:08:22.969Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:05:32.752Z' >
<A [24] [] '2023-01-10T03:08:10.606Z' >
>
>
>
>
.
2023-01-10 11:11:13,423: S6F12 W System Bytes=469
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:11:13,459: S2F44 System Bytes=28
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:11:13,962: S2F37 W System Bytes=29
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:11:14,013: S2F38 System Bytes=29
<B [1] [] '' 00 >
.
2023-01-10 11:11:14,526: S2F35 W System Bytes=30
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:11:14,561: S2F36 System Bytes=30
<B [1] [] '' 00 >
.
2023-01-10 11:11:15,071: S2F33 W System Bytes=31
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:11:15,072: S2F33 W System Bytes=31
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:11:15,124: S2F34 System Bytes=31
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:11:15,637: S5F3 W System Bytes=32
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:11:16,162: S2F33 W System Bytes=33
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:11:16,163: S2F33 W System Bytes=33
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:11:16,212: S2F34 System Bytes=33
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:11:16,724: S2F35 W System Bytes=34
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 11:11:16,773: S2F36 System Bytes=34
<B [1] [] '' 00 >
.
2023-01-10 11:11:17,282: S2F37 W System Bytes=35
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 11:11:17,332: S2F38 System Bytes=35
<B [1] [] '' 00 >
.
2023-01-10 11:11:17,844: S5F3 W System Bytes=36
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:11:18,403: S2F43 W System Bytes=37
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 11:11:18,440: S2F44 System Bytes=37
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:11:18,949: S1F3 W System Bytes=38
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:11:18,986: S1F4 System Bytes=38
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:08:28.524Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:11:19,496: S5F5 W System Bytes=39
<L [0]
>
.
2023-01-10 11:11:19,546: S5F6 System Bytes=39
<L [135]
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4065 >
<A [31] [ALTX] 'CV2: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4067 >
<A [29] [ALTX] 'CV2: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4066 >
<A [29] [ALTX] 'CV2: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4069 >
<A [40] [ALTX] 'CV2: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4068 >
<A [30] [ALTX] 'CV2: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4070 >
<A [20] [ALTX] 'CV2: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4073 >
<A [21] [ALTX] 'CV2: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3004 >
<A [36] [ALTX] 'EDS: Estop left infeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3005 >
<A [38] [ALTX] 'EDS: Estop right infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3006 >
<A [39] [ALTX] 'EDS: Estop right outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3007 >
<A [40] [ALTX] 'EDS: Estop right infeed inside activexxx' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3001 >
<A [25] [ALTX] 'EDS: Estop cabinet active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3002 >
<A [37] [ALTX] 'EDS: Estop left infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4086 >
<A [25] [ALTX] 'CV2: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3003 >
<A [38] [ALTX] 'EDS: Estop left outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3049 >
<A [38] [ALTX] 'EDS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4005 >
<A [43] [ALTX] 'CV2: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3048 >
<A [40] [ALTX] 'EDS: Safety fault feedback Estop circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4004 >
<A [25] [ALTX] 'CV2: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3051 >
<A [22] [ALTX] 'EDS: Error door left 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3050 >
<A [40] [ALTX] 'EDS: Safety fault feedback laser circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4006 >
<A [31] [ALTX] 'CV2: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3053 >
<A [22] [ALTX] 'EDS: Error door left 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4001 >
<A [22] [ALTX] 'CV2: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3052 >
<A [22] [ALTX] 'EDS: Error door left 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3055 >
<A [23] [ALTX] 'EDS: Error door right 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4003 >
<A [38] [ALTX] 'CV2: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3054 >
<A [22] [ALTX] 'EDS: Error door left 4' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4002 >
<A [23] [ALTX] 'CV2: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3041 >
<A [18] [ALTX] 'EDS: Error chiller' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3040 >
<A [28] [ALTX] 'EDS: time out vacuum outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3043 >
<A [26] [ALTX] 'EDS: Error aspiration unit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3042 >
<A [23] [ALTX] 'EDS: Error Flap outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3045 >
<A [29] [ALTX] 'EDS: Error drive align infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3044 >
<A [22] [ALTX] 'EDS: Error flap infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3047 >
<A [32] [ALTX] 'EDS: Error drive conveyor infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3046 >
<A [30] [ALTX] 'EDS: Error drive align outfeed' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4010 >
<A [22] [ALTX] 'CV2: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3064 >
<A [60] [ALTX] 'EDS: laser commisiioning active // automatik mode prohibited' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3065 >
<A [42] [ALTX] 'EDS: Interface downstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3066 >
<A [40] [ALTX] 'EDS: Interface upstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3067 >
<A [31] [ALTX] 'EDS: Interface downstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3068 >
<A [29] [ALTX] 'EDS: Interface upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3069 >
<A [41] [ALTX] 'EDS: gap sensor not free / transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3070 >
<A [20] [ALTX] 'EDS: HMI-PLC Timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3071 >
<A [33] [ALTX] 'EDS: Aligning axis not referenced' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3056 >
<A [23] [ALTX] 'EDS: Error door right 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3057 >
<A [23] [ALTX] 'EDS: Error door right 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3058 >
<A [23] [ALTX] 'EDS: Error door right 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3062 >
<A [33] [ALTX] 'EDS: Error drive conveyor outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3063 >
<A [50] [ALTX] 'EDS: Gripper free with data / glass not in gripper' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3019 >
<A [23] [ALTX] 'EDS: time out gripper 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1066 >
<A [29] [ALTX] 'CV1: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3018 >
<A [23] [ALTX] 'EDS: time out gripper 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1067 >
<A [29] [ALTX] 'CV1: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3017 >
<A [31] [ALTX] 'EDS: time out gripper Aligning2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3016 >
<A [31] [ALTX] 'EDS: time out gripper Aligning1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1065 >
<A [31] [ALTX] 'CV1: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3023 >
<A [30] [ALTX] 'EDS: time out gripper linear 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1070 >
<A [20] [ALTX] 'CV1: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3022 >
<A [23] [ALTX] 'EDS: time out gripper 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3021 >
<A [23] [ALTX] 'EDS: time out gripper 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1068 >
<A [30] [ALTX] 'CV1: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3020 >
<A [21] [ALTX] 'EDS: Fuse chiller NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1069 >
<A [40] [ALTX] 'CV1: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3011 >
<A [16] [ALTX] 'EDS: Laser error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3010 >
<A [31] [ALTX] 'EDS: Estop extern active active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3009 >
<A [41] [ALTX] 'EDS: Estop right outfeed inside activeyyy' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3008 >
<A [37] [ALTX] 'EDS: Estop left outfeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3015 >
<A [29] [ALTX] 'EDS: Fuse cabinet cooling NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3501 >
<A [42] [ALTX] 'EDS: Automatic power measurement requested' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3014 >
<A [31] [ALTX] 'EDS: Overvoltage protection NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3013 >
<A [33] [ALTX] 'EDS: Communication with Laser NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3012 >
<A [34] [ALTX] 'EDS: Fuse Power supply Laser 1 NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3034 >
<A [37] [ALTX] 'EDS: time out conveyor lifting infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3035 >
<A [38] [ALTX] 'EDS: time out conveyor lifting outfeed' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3505 >
<A [52] [ALTX] 'EDS: Laser simulation mode active. No laser emission' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3032 >
<A [28] [ALTX] 'EDS: Fuse 24V peripheral NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3506 >
<A [53] [ALTX] 'EDS: Aspiration settings too low. Beware of pollution' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3033 >
<A [23] [ALTX] 'EDS: Fuse 24V drive NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3038 >
<A [28] [ALTX] 'EDS: process stopped by user' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3039 >
<A [27] [ALTX] 'EDS: time out vacuum infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1086 >
<A [25] [ALTX] 'CV1: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3036 >
<A [30] [ALTX] 'EDS: time out gripper ref glas' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3037 >
<A [36] [ALTX] 'EDS: error air pressure out of range' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3026 >
<A [30] [ALTX] 'EDS: time out gripper linear 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3027 >
<A [34] [ALTX] 'EDS: Fuse 24V Operator buttons NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3024 >
<A [30] [ALTX] 'EDS: air conditioning CA fault' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1073 >
<A [21] [ALTX] 'CV1: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3025 >
<A [30] [ALTX] 'EDS: time out gripper linear 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3030 >
<A [30] [ALTX] 'EDS: time out gripper linear 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3031 >
<A [31] [ALTX] 'EDS: Fuse 24V miscellaneous NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3028 >
<A [24] [ALTX] 'EDS: Fuse supply Asi NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3029 >
<A [21] [ALTX] 'EDS: Fuse 24V IPC NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2065 >
<A [31] [ALTX] 'SBS: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2067 >
<A [29] [ALTX] 'SBS: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2066 >
<A [29] [ALTX] 'SBS: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2069 >
<A [40] [ALTX] 'SBS: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2068 >
<A [30] [ALTX] 'SBS: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2070 >
<A [20] [ALTX] 'SBS: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2073 >
<A [21] [ALTX] 'SBS: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2017 >
<A [19] [ALTX] 'SBS: Error lift low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2016 >
<A [27] [ALTX] 'SBS: Error single centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2019 >
<A [17] [ALTX] 'SBS: Error vacuum' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2018 >
<A [18] [ALTX] 'SBS: Error lift up' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2002 >
<A [23] [ALTX] 'SBS: Estop right active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2003 >
<A [38] [ALTX] 'SBS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2001 >
<A [22] [ALTX] 'SBS: Estop Left active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2006 >
<A [18] [ALTX] 'SBS: Error Brush 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2007 >
<A [18] [ALTX] 'SBS: Error Brush 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2004 >
<A [25] [ALTX] 'SBS: Error conveyor drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2005 >
<A [19] [ALTX] 'SBS: Error Brush 1 ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2010 >
<A [22] [ALTX] 'SBS: Estop line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2008 >
<A [18] [ALTX] 'SBS: Error Brush 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2009 >
<A [35] [ALTX] 'SBS: Error brush 1 linear movement ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2014 >
<A [34] [ALTX] 'SBS: Error brush 4 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2015 >
<A [25] [ALTX] 'SBS: Error dual centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2012 >
<A [34] [ALTX] 'SBS: Error brush 2 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2013 >
<A [34] [ALTX] 'SBS: Error brush 3 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2086 >
<A [25] [ALTX] 'SBS: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1010 >
<A [22] [ALTX] 'CV1: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1001 >
<A [22] [ALTX] 'CV1: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1003 >
<A [38] [ALTX] 'CV1: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1002 >
<A [23] [ALTX] 'CV1: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1005 >
<A [43] [ALTX] 'CV1: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1004 >
<A [25] [ALTX] 'CV1: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1006 >
<A [31] [ALTX] 'CV1: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3072 >
<A [32] [ALTX] 'EDS: Fuse Drives 400V supply NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3073 >
<A [38] [ALTX] 'EDS: SQ stopped by HMI => no PLC error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3074 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 1 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3075 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 2 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3076 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 3 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3077 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 4 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3078 >
<A [45] [ALTX] 'EDS: Aspiration flow ASP too low (upper head)' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3079 >
<A [45] [ALTX] 'EDS: Aspiration flow PHD too low (lower head)' >
>
>
.
2023-01-10 11:11:20,053: S7F19 W System Bytes=40
2023-01-10 11:11:20,089: S7F20 System Bytes=40
<L [8]
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
>
.
2023-01-10 11:11:20,593: S2F13 W System Bytes=0
<L [14]
<U4 [1] [EnableAlarmReportSend] 4 >
<U4 [1] [TimeFormat] 8 >
<U4 [1] [MaxTerminalMsgLength] 9 >
<U4 [1] [EstablishCommunicationsTimeout] 49 >
<U4 [1] [DefaultCommunicationState] 12 >
<U4 [1] [DefaultControlState] 15 >
<U4 [1] [DefaultOnlineSubState] 16 >
<U4 [1] [DefaultOfflineSubState] 17 >
<U4 [1] [EnableSpooling] 40 >
<U4 [1] [OverWriteSpool] 42 >
<U4 [1] [MaxSpoolMessages] 43 >
<U4 [1] [MaxSpoolTransmit] 44 >
<U4 [1] [MDLN] 1 >
<U4 [1] [SOFTREV] 2 >
>
.
2023-01-10 11:11:31,358: S1F13 W System Bytes=42
<L [0]
>
.
2023-01-10 11:11:31,644: S1F14 System Bytes=42
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:11:32,156: S1F17 W System Bytes=43
2023-01-10 11:11:32,191: S1F18 System Bytes=43
<B [1] [] '' 02 >
.
2023-01-10 11:11:32,697: S1F3 W System Bytes=44
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:11:32,733: S1F4 System Bytes=44
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:08:42.273Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 1 >
<U4 [1] [SpoolCountActual] 1 >
<U4 [1] [SpoolCountTotal] 1 >
>
.
2023-01-10 11:11:33,243: S6F23 W System Bytes=45
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:11:33,280: S6F24 System Bytes=45
<B [1] [] '' 00 >
.
2023-01-10 11:11:33,363: S6F11 W System Bytes=473
<L [3]
<U4 [1] [] 56 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:08:42.910Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:08:22.967Z' >
<A [24] [] '2023-01-10T03:08:29.909Z' >
>
>
>
>
.
2023-01-10 11:11:33,364: S6F12 W System Bytes=473
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:11:33,364: S2F43 W System Bytes=46
<L [0]
>
.
2023-01-10 11:11:33,453: S6F11 W System Bytes=474
<L [3]
<U4 [1] [] 57 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:08:42.988Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:08:22.967Z' >
<A [24] [] '2023-01-10T03:08:29.909Z' >
>
>
>
>
.
2023-01-10 11:11:33,454: S6F12 W System Bytes=474
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:11:33,491: S2F44 System Bytes=46
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:11:33,992: S2F37 W System Bytes=47
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:11:34,042: S2F38 System Bytes=47
<B [1] [] '' 00 >
.
2023-01-10 11:11:34,557: S2F35 W System Bytes=48
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:11:34,593: S2F36 System Bytes=48
<B [1] [] '' 00 >
.
2023-01-10 11:11:35,101: S2F33 W System Bytes=49
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:11:35,103: S2F33 W System Bytes=49
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:11:35,136: S2F34 System Bytes=49
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:11:35,646: S5F3 W System Bytes=50
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:11:36,191: S2F33 W System Bytes=51
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:11:36,193: S2F33 W System Bytes=51
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:11:36,242: S2F34 System Bytes=51
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:11:36,755: S2F35 W System Bytes=52
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 11:11:36,804: S2F36 System Bytes=52
<B [1] [] '' 00 >
.
2023-01-10 11:11:37,310: S2F37 W System Bytes=53
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 11:11:42,995: S1F13 W System Bytes=54
<L [0]
>
.
2023-01-10 11:11:43,275: S1F14 System Bytes=54
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:11:43,777: S1F17 W System Bytes=55
2023-01-10 11:11:52,945: S1F13 W System Bytes=56
<L [0]
>
.
2023-01-10 11:11:53,231: S1F14 System Bytes=56
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:11:53,737: S1F17 W System Bytes=57
2023-01-10 11:11:53,772: S1F18 System Bytes=57
<B [1] [] '' 02 >
.
2023-01-10 11:11:54,286: S1F3 W System Bytes=58
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:11:54,322: S1F4 System Bytes=58
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:09:03.861Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:11:54,828: S6F23 W System Bytes=59
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:11:54,866: S6F24 System Bytes=59
<B [1] [] '' 02 >
.
2023-01-10 11:11:55,371: S2F43 W System Bytes=60
<L [0]
>
.
2023-01-10 11:11:55,407: S2F44 System Bytes=60
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:11:55,916: S2F37 W System Bytes=61
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:11:55,968: S2F38 System Bytes=61
<B [1] [] '' 00 >
.
2023-01-10 11:11:56,478: S2F35 W System Bytes=62
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:12:02,978: S1F13 W System Bytes=63
<L [0]
>
.
2023-01-10 11:12:03,268: S1F14 System Bytes=63
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:12:03,776: S1F17 W System Bytes=64
2023-01-10 11:12:03,815: S1F18 System Bytes=64
<B [1] [] '' 02 >
.
2023-01-10 11:12:04,322: S1F3 W System Bytes=65
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:12:04,358: S1F4 System Bytes=65
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:09:13.898Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:12:04,866: S6F23 W System Bytes=66
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:12:04,902: S6F24 System Bytes=66
<B [1] [] '' 02 >
.
2023-01-10 11:12:05,410: S2F43 W System Bytes=67
<L [0]
>
.
2023-01-10 11:12:05,463: S2F44 System Bytes=67
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:12:05,975: S2F37 W System Bytes=68
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:12:06,027: S2F38 System Bytes=68
<B [1] [] '' 00 >
.
2023-01-10 11:12:06,536: S2F35 W System Bytes=69
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:12:06,573: S2F36 System Bytes=69
<B [1] [] '' 00 >
.
2023-01-10 11:12:07,081: S2F33 W System Bytes=70
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:12:07,082: S2F33 W System Bytes=70
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:12:07,116: S2F34 System Bytes=70
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:12:07,626: S5F3 W System Bytes=71
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:12:08,170: S2F33 W System Bytes=72
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:12:08,172: S2F33 W System Bytes=72
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:12:08,205: S2F34 System Bytes=72
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:12:08,712: S2F35 W System Bytes=73
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 11:12:08,764: S2F36 System Bytes=73
<B [1] [] '' 00 >
.
2023-01-10 11:12:09,269: S2F37 W System Bytes=74
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 11:12:09,322: S2F38 System Bytes=74
<B [1] [] '' 00 >
.
2023-01-10 11:12:09,838: S5F3 W System Bytes=75
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:12:10,376: S2F43 W System Bytes=76
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 11:12:10,412: S2F44 System Bytes=76
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:12:10,915: S1F3 W System Bytes=77
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:12:10,951: S1F4 System Bytes=77
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:09:20.491Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:12:11,453: S5F5 W System Bytes=78
<L [0]
>
.
2023-01-10 11:12:11,511: S5F6 System Bytes=78
<L [135]
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4065 >
<A [31] [ALTX] 'CV2: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4067 >
<A [29] [ALTX] 'CV2: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4066 >
<A [29] [ALTX] 'CV2: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4069 >
<A [40] [ALTX] 'CV2: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4068 >
<A [30] [ALTX] 'CV2: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4070 >
<A [20] [ALTX] 'CV2: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4073 >
<A [21] [ALTX] 'CV2: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3004 >
<A [36] [ALTX] 'EDS: Estop left infeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3005 >
<A [38] [ALTX] 'EDS: Estop right infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3006 >
<A [39] [ALTX] 'EDS: Estop right outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3007 >
<A [40] [ALTX] 'EDS: Estop right infeed inside activexxx' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3001 >
<A [25] [ALTX] 'EDS: Estop cabinet active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3002 >
<A [37] [ALTX] 'EDS: Estop left infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4086 >
<A [25] [ALTX] 'CV2: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3003 >
<A [38] [ALTX] 'EDS: Estop left outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3049 >
<A [38] [ALTX] 'EDS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4005 >
<A [43] [ALTX] 'CV2: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3048 >
<A [40] [ALTX] 'EDS: Safety fault feedback Estop circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4004 >
<A [25] [ALTX] 'CV2: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3051 >
<A [22] [ALTX] 'EDS: Error door left 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3050 >
<A [40] [ALTX] 'EDS: Safety fault feedback laser circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4006 >
<A [31] [ALTX] 'CV2: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3053 >
<A [22] [ALTX] 'EDS: Error door left 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4001 >
<A [22] [ALTX] 'CV2: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3052 >
<A [22] [ALTX] 'EDS: Error door left 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3055 >
<A [23] [ALTX] 'EDS: Error door right 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4003 >
<A [38] [ALTX] 'CV2: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3054 >
<A [22] [ALTX] 'EDS: Error door left 4' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4002 >
<A [23] [ALTX] 'CV2: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3041 >
<A [18] [ALTX] 'EDS: Error chiller' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3040 >
<A [28] [ALTX] 'EDS: time out vacuum outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3043 >
<A [26] [ALTX] 'EDS: Error aspiration unit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3042 >
<A [23] [ALTX] 'EDS: Error Flap outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3045 >
<A [29] [ALTX] 'EDS: Error drive align infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3044 >
<A [22] [ALTX] 'EDS: Error flap infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3047 >
<A [32] [ALTX] 'EDS: Error drive conveyor infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3046 >
<A [30] [ALTX] 'EDS: Error drive align outfeed' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4010 >
<A [22] [ALTX] 'CV2: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3064 >
<A [60] [ALTX] 'EDS: laser commisiioning active // automatik mode prohibited' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3065 >
<A [42] [ALTX] 'EDS: Interface downstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3066 >
<A [40] [ALTX] 'EDS: Interface upstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3067 >
<A [31] [ALTX] 'EDS: Interface downstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3068 >
<A [29] [ALTX] 'EDS: Interface upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3069 >
<A [41] [ALTX] 'EDS: gap sensor not free / transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3070 >
<A [20] [ALTX] 'EDS: HMI-PLC Timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3071 >
<A [33] [ALTX] 'EDS: Aligning axis not referenced' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3056 >
<A [23] [ALTX] 'EDS: Error door right 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3057 >
<A [23] [ALTX] 'EDS: Error door right 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3058 >
<A [23] [ALTX] 'EDS: Error door right 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3062 >
<A [33] [ALTX] 'EDS: Error drive conveyor outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3063 >
<A [50] [ALTX] 'EDS: Gripper free with data / glass not in gripper' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3019 >
<A [23] [ALTX] 'EDS: time out gripper 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1066 >
<A [29] [ALTX] 'CV1: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3018 >
<A [23] [ALTX] 'EDS: time out gripper 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1067 >
<A [29] [ALTX] 'CV1: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3017 >
<A [31] [ALTX] 'EDS: time out gripper Aligning2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3016 >
<A [31] [ALTX] 'EDS: time out gripper Aligning1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1065 >
<A [31] [ALTX] 'CV1: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3023 >
<A [30] [ALTX] 'EDS: time out gripper linear 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1070 >
<A [20] [ALTX] 'CV1: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3022 >
<A [23] [ALTX] 'EDS: time out gripper 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3021 >
<A [23] [ALTX] 'EDS: time out gripper 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1068 >
<A [30] [ALTX] 'CV1: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3020 >
<A [21] [ALTX] 'EDS: Fuse chiller NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1069 >
<A [40] [ALTX] 'CV1: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3011 >
<A [16] [ALTX] 'EDS: Laser error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3010 >
<A [31] [ALTX] 'EDS: Estop extern active active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3009 >
<A [41] [ALTX] 'EDS: Estop right outfeed inside activeyyy' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3008 >
<A [37] [ALTX] 'EDS: Estop left outfeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3015 >
<A [29] [ALTX] 'EDS: Fuse cabinet cooling NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3501 >
<A [42] [ALTX] 'EDS: Automatic power measurement requested' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3014 >
<A [31] [ALTX] 'EDS: Overvoltage protection NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3013 >
<A [33] [ALTX] 'EDS: Communication with Laser NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3012 >
<A [34] [ALTX] 'EDS: Fuse Power supply Laser 1 NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3034 >
<A [37] [ALTX] 'EDS: time out conveyor lifting infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3035 >
<A [38] [ALTX] 'EDS: time out conveyor lifting outfeed' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3505 >
<A [52] [ALTX] 'EDS: Laser simulation mode active. No laser emission' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3032 >
<A [28] [ALTX] 'EDS: Fuse 24V peripheral NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3506 >
<A [53] [ALTX] 'EDS: Aspiration settings too low. Beware of pollution' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3033 >
<A [23] [ALTX] 'EDS: Fuse 24V drive NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3038 >
<A [28] [ALTX] 'EDS: process stopped by user' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3039 >
<A [27] [ALTX] 'EDS: time out vacuum infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1086 >
<A [25] [ALTX] 'CV1: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3036 >
<A [30] [ALTX] 'EDS: time out gripper ref glas' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3037 >
<A [36] [ALTX] 'EDS: error air pressure out of range' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3026 >
<A [30] [ALTX] 'EDS: time out gripper linear 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3027 >
<A [34] [ALTX] 'EDS: Fuse 24V Operator buttons NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3024 >
<A [30] [ALTX] 'EDS: air conditioning CA fault' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1073 >
<A [21] [ALTX] 'CV1: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3025 >
<A [30] [ALTX] 'EDS: time out gripper linear 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3030 >
<A [30] [ALTX] 'EDS: time out gripper linear 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3031 >
<A [31] [ALTX] 'EDS: Fuse 24V miscellaneous NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3028 >
<A [24] [ALTX] 'EDS: Fuse supply Asi NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3029 >
<A [21] [ALTX] 'EDS: Fuse 24V IPC NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2065 >
<A [31] [ALTX] 'SBS: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2067 >
<A [29] [ALTX] 'SBS: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2066 >
<A [29] [ALTX] 'SBS: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2069 >
<A [40] [ALTX] 'SBS: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2068 >
<A [30] [ALTX] 'SBS: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2070 >
<A [20] [ALTX] 'SBS: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2073 >
<A [21] [ALTX] 'SBS: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2017 >
<A [19] [ALTX] 'SBS: Error lift low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2016 >
<A [27] [ALTX] 'SBS: Error single centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2019 >
<A [17] [ALTX] 'SBS: Error vacuum' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2018 >
<A [18] [ALTX] 'SBS: Error lift up' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2002 >
<A [23] [ALTX] 'SBS: Estop right active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2003 >
<A [38] [ALTX] 'SBS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2001 >
<A [22] [ALTX] 'SBS: Estop Left active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2006 >
<A [18] [ALTX] 'SBS: Error Brush 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2007 >
<A [18] [ALTX] 'SBS: Error Brush 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2004 >
<A [25] [ALTX] 'SBS: Error conveyor drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2005 >
<A [19] [ALTX] 'SBS: Error Brush 1 ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2010 >
<A [22] [ALTX] 'SBS: Estop line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2008 >
<A [18] [ALTX] 'SBS: Error Brush 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2009 >
<A [35] [ALTX] 'SBS: Error brush 1 linear movement ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2014 >
<A [34] [ALTX] 'SBS: Error brush 4 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2015 >
<A [25] [ALTX] 'SBS: Error dual centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2012 >
<A [34] [ALTX] 'SBS: Error brush 2 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2013 >
<A [34] [ALTX] 'SBS: Error brush 3 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2086 >
<A [25] [ALTX] 'SBS: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1010 >
<A [22] [ALTX] 'CV1: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1001 >
<A [22] [ALTX] 'CV1: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1003 >
<A [38] [ALTX] 'CV1: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1002 >
<A [23] [ALTX] 'CV1: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1005 >
<A [43] [ALTX] 'CV1: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1004 >
<A [25] [ALTX] 'CV1: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1006 >
<A [31] [ALTX] 'CV1: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3072 >
<A [32] [ALTX] 'EDS: Fuse Drives 400V supply NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3073 >
<A [38] [ALTX] 'EDS: SQ stopped by HMI => no PLC error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3074 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 1 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3075 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 2 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3076 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 3 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3077 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 4 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3078 >
<A [45] [ALTX] 'EDS: Aspiration flow ASP too low (upper head)' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3079 >
<A [45] [ALTX] 'EDS: Aspiration flow PHD too low (lower head)' >
>
>
.
2023-01-10 11:12:12,024: S7F19 W System Bytes=79
2023-01-10 11:12:12,076: S7F20 System Bytes=79
<L [8]
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
>
.
2023-01-10 11:12:12,584: S2F13 W System Bytes=0
<L [14]
<U4 [1] [EnableAlarmReportSend] 4 >
<U4 [1] [TimeFormat] 8 >
<U4 [1] [MaxTerminalMsgLength] 9 >
<U4 [1] [EstablishCommunicationsTimeout] 49 >
<U4 [1] [DefaultCommunicationState] 12 >
<U4 [1] [DefaultControlState] 15 >
<U4 [1] [DefaultOnlineSubState] 16 >
<U4 [1] [DefaultOfflineSubState] 17 >
<U4 [1] [EnableSpooling] 40 >
<U4 [1] [OverWriteSpool] 42 >
<U4 [1] [MaxSpoolMessages] 43 >
<U4 [1] [MaxSpoolTransmit] 44 >
<U4 [1] [MDLN] 1 >
<U4 [1] [SOFTREV] 2 >
>
.
2023-01-10 11:12:12,620: S2F14 System Bytes=80
<L [14]
<BOOLEAN [1] [EnableAlarmReportSend] T >
<U1 [1] [TimeFormat] 2 >
<U4 [1] [MaxTerminalMsgLength] 80 >
<I2 [1] [EstablishCommunicationsTimeout] 30 >
<U1 [1] [DefaultCommunicationState] 1 >
<U1 [1] [DefaultControlState] 5 >
<U1 [1] [DefaultOnlineSubState] 5 >
<U1 [1] [DefaultOfflineSubState] 2 >
<BOOLEAN [1] [EnableSpooling] T >
<BOOLEAN [1] [OverWriteSpool] T >
<U4 [1] [MaxSpoolMessages] 100000 >
<U4 [1] [MaxSpoolTransmit] 0 >
<L [0]
>
<L [0]
>
>
.
2023-01-10 11:12:13,127: S2F15 W System Bytes=81
<L [2]
<L [2]
<U4 [1] [DefaultControlState] 15 >
<U1 [1] [ECV] 5 >
>
<L [2]
<U4 [1] [DefaultOnlineSubState] 16 >
<U1 [1] [ECV] 5 >
>
>
.
2023-01-10 11:12:13,163: S2F16 System Bytes=81
<B [1] [] '' 00 >
.
2023-01-10 11:12:13,677: S1F15 W System Bytes=82
2023-01-10 11:12:13,695: S1F16 System Bytes=82
<B [1] [] '' 00 >
.
2023-01-10 11:12:13,696: S6F11 W System Bytes=481
<L [3]
<U4 [1] [] 58 >
<U4 [1] [] 1 >
<L [1]
<L [2]
<U4 [1] [] 1 >
<L [3]
<A [24] [Clock] '2023-01-10T03:09:23.236Z' >
<U1 [1] [CurrentControlState] 3 >
<U1 [1] [PreviousControlState] 5 >
>
>
>
>
.
2023-01-10 11:12:13,696: S6F12 W System Bytes=481
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:12:14,201: S1F17 W System Bytes=83
2023-01-10 11:12:14,231: S6F11 W System Bytes=482
<L [3]
<U4 [1] [] 59 >
<U4 [1] [] 3 >
<L [1]
<L [2]
<U4 [1] [] 3 >
<L [3]
<A [24] [Clock] '2023-01-10T03:09:23.777Z' >
<U1 [1] [CurrentControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
>
>
>
>
.
2023-01-10 11:12:14,234: S6F12 W System Bytes=482
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:12:14,237: S1F18 System Bytes=83
<B [1] [] '' 00 >
.
2023-01-10 11:12:14,746: S1F3 W System Bytes=84
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:12:14,783: S1F4 System Bytes=84
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:09:24.319Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:12:15,284: S2F23 W System Bytes=85
<L [5]
<U4 [1] [TRID] 1 >
<A [6] [DSPER_hhmmss] '000010' >
<U4 [1] [TOTSMP] 0 >
<U4 [1] [REPGSZ] 1 >
<L [0]
>
>
.
2023-01-10 11:12:15,321: S2F24 System Bytes=85
<B [1] [] '' 00 >
.
2023-01-10 11:12:45,090: S1F13 W System Bytes=86
<L [0]
>
.
2023-01-10 11:12:45,367: S1F14 System Bytes=86
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:12:45,873: S1F17 W System Bytes=87
2023-01-10 11:12:45,909: S1F18 System Bytes=87
<B [1] [] '' 02 >
.
2023-01-10 11:12:46,418: S1F3 W System Bytes=88
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:12:46,456: S1F4 System Bytes=88
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:09:55.993Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 1 >
<U4 [1] [SpoolCountActual] 2 >
<U4 [1] [SpoolCountTotal] 2 >
>
.
2023-01-10 11:12:46,968: S6F23 W System Bytes=89
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:12:47,005: S6F24 System Bytes=89
<B [1] [] '' 00 >
.
2023-01-10 11:12:47,091: S6F11 W System Bytes=488
<L [3]
<U4 [1] [] 62 >
<U4 [1] [] 300012 >
<L [1]
<L [2]
<U4 [1] [] 200012 >
<L [12]
<A [24] [Clock] '2023-01-10T03:09:48.389Z' >
<A [17] [SubstrateID] 'a2023010903310702' >
<A [4] [LocationID] 'LEDE' >
<BOOLEAN [1] [MaterialStatus] F >
<U4 [1] [Target A] 0 >
<U4 [1] [Target B] 0 >
<U4 [1] [Target C] 0 >
<U4 [1] [Target D] 0 >
<U4 [1] [Reroute A] 0 >
<U4 [1] [Reroute B] 0 >
<U4 [1] [Reroute C] 0 >
<U4 [1] [Reroute D] 0 >
>
>
>
>
.
2023-01-10 11:12:47,091: S6F12 W System Bytes=488
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:12:47,119: S6F11 W System Bytes=489
<L [3]
<U4 [1] [] 63 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:09:56.658Z' >
<U1 [1] [] 0 >
<U4 [1] [] 2 >
<U4 [1] [] 2 >
<A [24] [] '2023-01-10T03:09:14.988Z' >
<A [24] [] '2023-01-10T03:09:43.710Z' >
>
>
>
>
.
2023-01-10 11:12:47,119: S6F12 W System Bytes=489
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:12:47,120: S2F43 W System Bytes=90
<L [0]
>
.
2023-01-10 11:12:47,194: S6F11 W System Bytes=490
<L [3]
<U4 [1] [] 64 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:09:56.741Z' >
<U1 [1] [] 0 >
<U4 [1] [] 2 >
<U4 [1] [] 2 >
<A [24] [] '2023-01-10T03:09:14.988Z' >
<A [24] [] '2023-01-10T03:09:43.710Z' >
>
>
>
>
.
2023-01-10 11:12:47,195: S6F12 W System Bytes=490
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:12:47,232: S2F44 System Bytes=90
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:12:47,739: S2F37 W System Bytes=91
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:12:47,775: S2F38 System Bytes=91
<B [1] [] '' 00 >
.
2023-01-10 11:12:48,281: S2F35 W System Bytes=92
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:12:48,316: S2F36 System Bytes=92
<B [1] [] '' 00 >
.
2023-01-10 11:12:48,830: S2F33 W System Bytes=93
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:12:48,831: S2F33 W System Bytes=93
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:12:48,865: S2F34 System Bytes=93
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:12:49,375: S5F3 W System Bytes=94
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:12:49,937: S2F33 W System Bytes=95
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:12:49,938: S2F33 W System Bytes=95
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:12:49,972: S2F34 System Bytes=95
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:12:50,482: S2F35 W System Bytes=96
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 11:12:50,533: S2F36 System Bytes=96
<B [1] [] '' 00 >
.
2023-01-10 11:12:51,042: S2F37 W System Bytes=97
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 11:12:51,096: S2F38 System Bytes=97
<B [1] [] '' 00 >
.
2023-01-10 11:12:51,600: S5F3 W System Bytes=98
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:12:52,143: S2F43 W System Bytes=99
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 11:12:52,183: S2F44 System Bytes=99
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:12:52,689: S1F3 W System Bytes=100
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:12:52,724: S1F4 System Bytes=100
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:10:02.264Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:12:53,226: S5F5 W System Bytes=101
<L [0]
>
.
2023-01-10 11:13:05,114: S1F13 W System Bytes=102
<L [0]
>
.
2023-01-10 11:13:05,397: S1F14 System Bytes=102
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 11:13:05,909: S1F17 W System Bytes=103
2023-01-10 11:13:05,944: S1F18 System Bytes=103
<B [1] [] '' 02 >
.
2023-01-10 11:13:06,449: S1F3 W System Bytes=104
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:13:06,485: S1F4 System Bytes=104
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:10:16.023Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 1 >
<U4 [1] [SpoolCountActual] 1 >
<U4 [1] [SpoolCountTotal] 1 >
>
.
2023-01-10 11:13:06,998: S6F23 W System Bytes=105
<U1 [1] [RSDC] 0 >
.
2023-01-10 11:13:07,034: S6F24 System Bytes=105
<B [1] [] '' 00 >
.
2023-01-10 11:13:07,118: S6F11 W System Bytes=494
<L [3]
<U4 [1] [] 66 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:10:16.663Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:09:56.738Z' >
<A [24] [] '2023-01-10T03:10:03.014Z' >
>
>
>
>
.
2023-01-10 11:13:07,118: S6F12 W System Bytes=494
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:13:07,118: S2F43 W System Bytes=106
<L [0]
>
.
2023-01-10 11:13:07,193: S6F11 W System Bytes=495
<L [3]
<U4 [1] [] 67 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T03:10:16.737Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:09:56.738Z' >
<A [24] [] '2023-01-10T03:10:03.014Z' >
>
>
>
>
.
2023-01-10 11:13:07,194: S6F12 W System Bytes=495
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:13:07,229: S2F44 System Bytes=106
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:13:07,738: S2F37 W System Bytes=107
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 11:13:07,773: S2F38 System Bytes=107
<B [1] [] '' 00 >
.
2023-01-10 11:13:08,281: S2F35 W System Bytes=108
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:13:08,318: S2F36 System Bytes=108
<B [1] [] '' 00 >
.
2023-01-10 11:13:08,826: S2F33 W System Bytes=109
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:13:08,827: S2F33 W System Bytes=109
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 11:13:08,862: S2F34 System Bytes=109
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:13:09,374: S5F3 W System Bytes=110
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:13:09,923: S2F33 W System Bytes=111
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:13:09,925: S2F33 W System Bytes=111
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 11:13:09,959: S2F34 System Bytes=111
<B [1] [DRACK] '' 00 >
.
2023-01-10 11:13:10,472: S2F35 W System Bytes=112
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 11:13:10,508: S2F36 System Bytes=112
<B [1] [] '' 00 >
.
2023-01-10 11:13:11,019: S2F37 W System Bytes=113
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 11:13:11,069: S2F38 System Bytes=113
<B [1] [] '' 00 >
.
2023-01-10 11:13:11,573: S5F3 W System Bytes=114
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 11:13:12,116: S2F43 W System Bytes=115
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 11:13:12,152: S2F44 System Bytes=115
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 11:13:12,660: S1F3 W System Bytes=116
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:13:12,695: S1F4 System Bytes=116
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:10:22.234Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:13:13,209: S5F5 W System Bytes=117
<L [0]
>
.
2023-01-10 11:13:13,264: S5F6 System Bytes=117
<L [135]
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4065 >
<A [31] [ALTX] 'CV2: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4067 >
<A [29] [ALTX] 'CV2: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4066 >
<A [29] [ALTX] 'CV2: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4069 >
<A [40] [ALTX] 'CV2: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4068 >
<A [30] [ALTX] 'CV2: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4070 >
<A [20] [ALTX] 'CV2: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4073 >
<A [21] [ALTX] 'CV2: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3004 >
<A [36] [ALTX] 'EDS: Estop left infeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3005 >
<A [38] [ALTX] 'EDS: Estop right infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3006 >
<A [39] [ALTX] 'EDS: Estop right outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3007 >
<A [40] [ALTX] 'EDS: Estop right infeed inside activexxx' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3001 >
<A [25] [ALTX] 'EDS: Estop cabinet active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3002 >
<A [37] [ALTX] 'EDS: Estop left infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4086 >
<A [25] [ALTX] 'CV2: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3003 >
<A [38] [ALTX] 'EDS: Estop left outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3049 >
<A [38] [ALTX] 'EDS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4005 >
<A [43] [ALTX] 'CV2: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3048 >
<A [40] [ALTX] 'EDS: Safety fault feedback Estop circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4004 >
<A [25] [ALTX] 'CV2: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3051 >
<A [22] [ALTX] 'EDS: Error door left 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3050 >
<A [40] [ALTX] 'EDS: Safety fault feedback laser circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4006 >
<A [31] [ALTX] 'CV2: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3053 >
<A [22] [ALTX] 'EDS: Error door left 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4001 >
<A [22] [ALTX] 'CV2: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3052 >
<A [22] [ALTX] 'EDS: Error door left 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3055 >
<A [23] [ALTX] 'EDS: Error door right 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4003 >
<A [38] [ALTX] 'CV2: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3054 >
<A [22] [ALTX] 'EDS: Error door left 4' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4002 >
<A [23] [ALTX] 'CV2: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3041 >
<A [18] [ALTX] 'EDS: Error chiller' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3040 >
<A [28] [ALTX] 'EDS: time out vacuum outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3043 >
<A [26] [ALTX] 'EDS: Error aspiration unit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3042 >
<A [23] [ALTX] 'EDS: Error Flap outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3045 >
<A [29] [ALTX] 'EDS: Error drive align infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3044 >
<A [22] [ALTX] 'EDS: Error flap infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3047 >
<A [32] [ALTX] 'EDS: Error drive conveyor infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3046 >
<A [30] [ALTX] 'EDS: Error drive align outfeed' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4010 >
<A [22] [ALTX] 'CV2: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3064 >
<A [60] [ALTX] 'EDS: laser commisiioning active // automatik mode prohibited' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3065 >
<A [42] [ALTX] 'EDS: Interface downstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3066 >
<A [40] [ALTX] 'EDS: Interface upstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3067 >
<A [31] [ALTX] 'EDS: Interface downstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3068 >
<A [29] [ALTX] 'EDS: Interface upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3069 >
<A [41] [ALTX] 'EDS: gap sensor not free / transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3070 >
<A [20] [ALTX] 'EDS: HMI-PLC Timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3071 >
<A [33] [ALTX] 'EDS: Aligning axis not referenced' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3056 >
<A [23] [ALTX] 'EDS: Error door right 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3057 >
<A [23] [ALTX] 'EDS: Error door right 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3058 >
<A [23] [ALTX] 'EDS: Error door right 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3062 >
<A [33] [ALTX] 'EDS: Error drive conveyor outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3063 >
<A [50] [ALTX] 'EDS: Gripper free with data / glass not in gripper' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3019 >
<A [23] [ALTX] 'EDS: time out gripper 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1066 >
<A [29] [ALTX] 'CV1: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3018 >
<A [23] [ALTX] 'EDS: time out gripper 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1067 >
<A [29] [ALTX] 'CV1: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3017 >
<A [31] [ALTX] 'EDS: time out gripper Aligning2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3016 >
<A [31] [ALTX] 'EDS: time out gripper Aligning1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1065 >
<A [31] [ALTX] 'CV1: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3023 >
<A [30] [ALTX] 'EDS: time out gripper linear 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1070 >
<A [20] [ALTX] 'CV1: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3022 >
<A [23] [ALTX] 'EDS: time out gripper 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3021 >
<A [23] [ALTX] 'EDS: time out gripper 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1068 >
<A [30] [ALTX] 'CV1: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3020 >
<A [21] [ALTX] 'EDS: Fuse chiller NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1069 >
<A [40] [ALTX] 'CV1: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3011 >
<A [16] [ALTX] 'EDS: Laser error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3010 >
<A [31] [ALTX] 'EDS: Estop extern active active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3009 >
<A [41] [ALTX] 'EDS: Estop right outfeed inside activeyyy' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3008 >
<A [37] [ALTX] 'EDS: Estop left outfeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3015 >
<A [29] [ALTX] 'EDS: Fuse cabinet cooling NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3501 >
<A [42] [ALTX] 'EDS: Automatic power measurement requested' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3014 >
<A [31] [ALTX] 'EDS: Overvoltage protection NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3013 >
<A [33] [ALTX] 'EDS: Communication with Laser NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3012 >
<A [34] [ALTX] 'EDS: Fuse Power supply Laser 1 NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3034 >
<A [37] [ALTX] 'EDS: time out conveyor lifting infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3035 >
<A [38] [ALTX] 'EDS: time out conveyor lifting outfeed' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3505 >
<A [52] [ALTX] 'EDS: Laser simulation mode active. No laser emission' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3032 >
<A [28] [ALTX] 'EDS: Fuse 24V peripheral NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3506 >
<A [53] [ALTX] 'EDS: Aspiration settings too low. Beware of pollution' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3033 >
<A [23] [ALTX] 'EDS: Fuse 24V drive NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3038 >
<A [28] [ALTX] 'EDS: process stopped by user' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3039 >
<A [27] [ALTX] 'EDS: time out vacuum infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1086 >
<A [25] [ALTX] 'CV1: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3036 >
<A [30] [ALTX] 'EDS: time out gripper ref glas' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3037 >
<A [36] [ALTX] 'EDS: error air pressure out of range' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3026 >
<A [30] [ALTX] 'EDS: time out gripper linear 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3027 >
<A [34] [ALTX] 'EDS: Fuse 24V Operator buttons NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3024 >
<A [30] [ALTX] 'EDS: air conditioning CA fault' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1073 >
<A [21] [ALTX] 'CV1: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3025 >
<A [30] [ALTX] 'EDS: time out gripper linear 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3030 >
<A [30] [ALTX] 'EDS: time out gripper linear 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3031 >
<A [31] [ALTX] 'EDS: Fuse 24V miscellaneous NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3028 >
<A [24] [ALTX] 'EDS: Fuse supply Asi NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3029 >
<A [21] [ALTX] 'EDS: Fuse 24V IPC NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2065 >
<A [31] [ALTX] 'SBS: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2067 >
<A [29] [ALTX] 'SBS: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2066 >
<A [29] [ALTX] 'SBS: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2069 >
<A [40] [ALTX] 'SBS: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2068 >
<A [30] [ALTX] 'SBS: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2070 >
<A [20] [ALTX] 'SBS: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2073 >
<A [21] [ALTX] 'SBS: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2017 >
<A [19] [ALTX] 'SBS: Error lift low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2016 >
<A [27] [ALTX] 'SBS: Error single centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2019 >
<A [17] [ALTX] 'SBS: Error vacuum' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2018 >
<A [18] [ALTX] 'SBS: Error lift up' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2002 >
<A [23] [ALTX] 'SBS: Estop right active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2003 >
<A [38] [ALTX] 'SBS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2001 >
<A [22] [ALTX] 'SBS: Estop Left active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2006 >
<A [18] [ALTX] 'SBS: Error Brush 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2007 >
<A [18] [ALTX] 'SBS: Error Brush 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2004 >
<A [25] [ALTX] 'SBS: Error conveyor drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2005 >
<A [19] [ALTX] 'SBS: Error Brush 1 ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2010 >
<A [22] [ALTX] 'SBS: Estop line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2008 >
<A [18] [ALTX] 'SBS: Error Brush 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2009 >
<A [35] [ALTX] 'SBS: Error brush 1 linear movement ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2014 >
<A [34] [ALTX] 'SBS: Error brush 4 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2015 >
<A [25] [ALTX] 'SBS: Error dual centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2012 >
<A [34] [ALTX] 'SBS: Error brush 2 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2013 >
<A [34] [ALTX] 'SBS: Error brush 3 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2086 >
<A [25] [ALTX] 'SBS: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1010 >
<A [22] [ALTX] 'CV1: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1001 >
<A [22] [ALTX] 'CV1: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1003 >
<A [38] [ALTX] 'CV1: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1002 >
<A [23] [ALTX] 'CV1: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1005 >
<A [43] [ALTX] 'CV1: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1004 >
<A [25] [ALTX] 'CV1: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1006 >
<A [31] [ALTX] 'CV1: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3072 >
<A [32] [ALTX] 'EDS: Fuse Drives 400V supply NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3073 >
<A [38] [ALTX] 'EDS: SQ stopped by HMI => no PLC error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3074 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 1 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3075 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 2 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3076 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 3 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3077 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 4 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3078 >
<A [45] [ALTX] 'EDS: Aspiration flow ASP too low (upper head)' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3079 >
<A [45] [ALTX] 'EDS: Aspiration flow PHD too low (lower head)' >
>
>
.
2023-01-10 11:13:13,769: S7F19 W System Bytes=118
2023-01-10 11:13:13,805: S7F20 System Bytes=118
<L [8]
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
>
.
2023-01-10 11:13:14,314: S2F13 W System Bytes=0
<L [14]
<U4 [1] [EnableAlarmReportSend] 4 >
<U4 [1] [TimeFormat] 8 >
<U4 [1] [MaxTerminalMsgLength] 9 >
<U4 [1] [EstablishCommunicationsTimeout] 49 >
<U4 [1] [DefaultCommunicationState] 12 >
<U4 [1] [DefaultControlState] 15 >
<U4 [1] [DefaultOnlineSubState] 16 >
<U4 [1] [DefaultOfflineSubState] 17 >
<U4 [1] [EnableSpooling] 40 >
<U4 [1] [OverWriteSpool] 42 >
<U4 [1] [MaxSpoolMessages] 43 >
<U4 [1] [MaxSpoolTransmit] 44 >
<U4 [1] [MDLN] 1 >
<U4 [1] [SOFTREV] 2 >
>
.
2023-01-10 11:13:14,350: S2F14 System Bytes=119
<L [14]
<BOOLEAN [1] [EnableAlarmReportSend] T >
<U1 [1] [TimeFormat] 2 >
<U4 [1] [MaxTerminalMsgLength] 80 >
<I2 [1] [EstablishCommunicationsTimeout] 30 >
<U1 [1] [DefaultCommunicationState] 1 >
<U1 [1] [DefaultControlState] 5 >
<U1 [1] [DefaultOnlineSubState] 5 >
<U1 [1] [DefaultOfflineSubState] 2 >
<BOOLEAN [1] [EnableSpooling] T >
<BOOLEAN [1] [OverWriteSpool] T >
<U4 [1] [MaxSpoolMessages] 100000 >
<U4 [1] [MaxSpoolTransmit] 0 >
<L [0]
>
<L [0]
>
>
.
2023-01-10 11:13:14,860: S2F15 W System Bytes=120
<L [2]
<L [2]
<U4 [1] [DefaultControlState] 15 >
<U1 [1] [ECV] 5 >
>
<L [2]
<U4 [1] [DefaultOnlineSubState] 16 >
<U1 [1] [ECV] 5 >
>
>
.
2023-01-10 11:13:14,897: S2F16 System Bytes=120
<B [1] [] '' 00 >
.
2023-01-10 11:13:15,409: S1F15 W System Bytes=121
2023-01-10 11:13:15,444: S1F16 System Bytes=121
<B [1] [] '' 00 >
.
2023-01-10 11:13:15,444: S6F11 W System Bytes=496
<L [3]
<U4 [1] [] 68 >
<U4 [1] [] 1 >
<L [1]
<L [2]
<U4 [1] [] 1 >
<L [3]
<A [24] [Clock] '2023-01-10T03:10:24.982Z' >
<U1 [1] [CurrentControlState] 3 >
<U1 [1] [PreviousControlState] 5 >
>
>
>
>
.
2023-01-10 11:13:15,445: S6F12 W System Bytes=496
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:13:15,952: S1F17 W System Bytes=122
2023-01-10 11:13:15,983: S6F11 W System Bytes=497
<L [3]
<U4 [1] [] 69 >
<U4 [1] [] 3 >
<L [1]
<L [2]
<U4 [1] [] 3 >
<L [3]
<A [24] [Clock] '2023-01-10T03:10:25.528Z' >
<U1 [1] [CurrentControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
>
>
>
>
.
2023-01-10 11:13:15,987: S6F12 W System Bytes=497
<B [1] [ACKC6] '' 00 >
.
2023-01-10 11:13:15,991: S1F18 System Bytes=122
<B [1] [] '' 00 >
.
2023-01-10 11:13:16,513: S1F3 W System Bytes=123
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 11:13:16,548: S1F4 System Bytes=123
<L [10]
<A [24] [eventTimestamp] '2023-01-10T03:10:26.086Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 11:13:17,053: S2F23 W System Bytes=124
<L [5]
<U4 [1] [TRID] 1 >
<A [6] [DSPER_hhmmss] '000010' >
<U4 [1] [TOTSMP] 0 >
<U4 [1] [REPGSZ] 1 >
<L [0]
>
>
.
2023-01-10 11:13:17,089: S2F24 System Bytes=124
<B [1] [] '' 00 >
.
2023-01-10 13:05:02,169: S1F13 W System Bytes=1
<L [0]
>
.
2023-01-10 13:05:02,464: S1F14 System Bytes=1
<L [2]
<B [1] [COMMACK] '' 00 >
<L [2]
<A [6] [] 'EQPTST' >
<A [6] [] 'V1.0.0' >
>
>
.
2023-01-10 13:05:02,975: S1F17 W System Bytes=2
2023-01-10 13:05:03,010: S1F18 System Bytes=2
<B [1] [] '' 02 >
.
2023-01-10 13:05:03,527: S1F3 W System Bytes=3
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 13:05:03,563: S1F4 System Bytes=3
<L [10]
<A [24] [eventTimestamp] '2023-01-10T05:02:13.054Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 1 >
<U4 [1] [SpoolCountActual] 1 >
<U4 [1] [SpoolCountTotal] 1 >
>
.
2023-01-10 13:05:04,071: S6F23 W System Bytes=4
<U1 [1] [RSDC] 0 >
.
2023-01-10 13:05:04,106: S6F24 System Bytes=4
<B [1] [] '' 00 >
.
2023-01-10 13:05:04,193: S6F11 W System Bytes=689
<L [3]
<U4 [1] [] 71 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T05:02:13.692Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:10:16.735Z' >
<A [24] [] '2023-01-10T04:47:37.705Z' >
>
>
>
>
.
2023-01-10 13:05:04,193: S6F12 W System Bytes=689
<B [1] [ACKC6] '' 00 >
.
2023-01-10 13:05:04,194: S2F43 W System Bytes=5
<L [0]
>
.
2023-01-10 13:05:04,267: S6F11 W System Bytes=690
<L [3]
<U4 [1] [] 72 >
<U4 [1] [] 23 >
<L [1]
<L [2]
<U4 [1] [] 23 >
<L [6]
<A [24] [] '2023-01-10T05:02:13.769Z' >
<U1 [1] [] 0 >
<U4 [1] [] 1 >
<U4 [1] [] 1 >
<A [24] [] '2023-01-10T03:10:16.735Z' >
<A [24] [] '2023-01-10T04:47:37.705Z' >
>
>
>
>
.
2023-01-10 13:05:04,268: S6F12 W System Bytes=690
<B [1] [ACKC6] '' 00 >
.
2023-01-10 13:05:04,305: S2F44 System Bytes=5
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 13:05:04,815: S2F37 W System Bytes=6
<L [2]
<BOOLEAN [1] [CEED] F >
<L [0]
>
>
.
2023-01-10 13:05:04,866: S2F38 System Bytes=6
<B [1] [] '' 00 >
.
2023-01-10 13:05:05,375: S2F35 W System Bytes=7
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 13:05:05,408: S2F36 System Bytes=7
<B [1] [] '' 00 >
.
2023-01-10 13:05:05,918: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 13:05:05,918: S2F33 W System Bytes=8
<L [2]
<U4 [1] [DATAID] 0 >
<L [0]
>
>
.
2023-01-10 13:05:05,952: S2F34 System Bytes=8
<B [1] [DRACK] '' 00 >
.
2023-01-10 13:05:06,467: S5F3 W System Bytes=9
<L [2]
<B [1] [ALED] '' 00 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 13:05:07,009: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 13:05:07,010: S2F33 W System Bytes=10
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [reportid] 1 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 2 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 3 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
>
>
<L [2]
<U4 [1] [reportid] 11 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 12 >
<L [4]
<U4 [1] [Clock] 3 >
<U4 [1] [AlarmID] 5 >
<U4 [1] [AlarmText] 6 >
<U4 [1] [AlarmsCategory] 7 >
>
>
<L [2]
<U4 [1] [reportid] 21 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 22 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 23 >
<L [6]
<U4 [1] [Clock] 3 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
<U4 [1] [SpoolFullTime] 47 >
<U4 [1] [SpoolStartTime] 48 >
>
>
<L [2]
<U4 [1] [reportid] 200011 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [MaterialStatus] 1001 >
>
>
<L [2]
<U4 [1] [reportid] 200012 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200013 >
<L [12]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [LocationID] 1010 >
<U4 [1] [MaterialStatus] 1001 >
<U4 [1] [Target A] 1002 >
<U4 [1] [Target B] 1003 >
<U4 [1] [Target C] 1004 >
<U4 [1] [Target D] 1005 >
<U4 [1] [Reroute A] 1006 >
<U4 [1] [Reroute B] 1007 >
<U4 [1] [Reroute C] 1008 >
<U4 [1] [Reroute D] 1009 >
>
>
<L [2]
<U4 [1] [reportid] 200021 >
<L [5]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
<L [2]
<U4 [1] [reportid] 200022 >
<L [16]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [ProcessResult] 1013 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [ProcessDurationSBS] 1015 >
<U4 [1] [ProcessDurationEDS] 1016 >
<U4 [1] [ProcessRecipeId] 1017 >
<U4 [1] [ProcessRecipeName] 1018 >
<U4 [1] [ProcessRecipeVersion] 1019 >
<U4 [1] [ProcessRecipeCreationDate] 1020 >
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
<U4 [1] [MeasuredSubstrateWidth] 1024 >
<U4 [1] [MeasuredSubstrateLength] 1025 >
>
>
<L [2]
<U4 [1] [reportid] 200032 >
<L [56]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID_CV1] 1046 >
<U4 [1] [SubstrateID_SBS] 1047 >
<U4 [1] [SubstrateID_EDS1] 1048 >
<U4 [1] [SubstrateID_EDS2] 1049 >
<U4 [1] [SubstrateID_CV2] 1050 >
<U4 [1] [LocationId_CV1] 1051 >
<U4 [1] [LocationId_SBS] 1052 >
<U4 [1] [LocationId_EDS1] 1053 >
<U4 [1] [LocationId_EDS2] 1054 >
<U4 [1] [LocationId_CV2] 1055 >
<U4 [1] [Slot1_CV1] 1056 >
<U4 [1] [Slot1_SBS] 1057 >
<U4 [1] [Slot1_EDS1] 1058 >
<U4 [1] [Slot1_EDS2] 1059 >
<U4 [1] [Slot1_CV2] 1060 >
<U4 [1] [Target_A_1] 1061 >
<U4 [1] [Target_A_2] 1062 >
<U4 [1] [Target_A_3] 1063 >
<U4 [1] [Target_A_4] 1064 >
<U4 [1] [Target_A_5] 1065 >
<U4 [1] [Target_B_1] 1066 >
<U4 [1] [Target_B_2] 1067 >
<U4 [1] [Target_B_3] 1068 >
<U4 [1] [Target_B_4] 1069 >
<U4 [1] [Target_B_5] 1070 >
<U4 [1] [Target_C_1] 1071 >
<U4 [1] [Target_C_2] 1072 >
<U4 [1] [Target_C_3] 1073 >
<U4 [1] [Target_C_4] 1074 >
<U4 [1] [Target_C_5] 1075 >
<U4 [1] [Target_D_1] 1076 >
<U4 [1] [Target_D_2] 1077 >
<U4 [1] [Target_D_3] 1078 >
<U4 [1] [Target_D_4] 1079 >
<U4 [1] [Target_D_5] 1080 >
<U4 [1] [Reroute_A_1] 1081 >
<U4 [1] [Reroute_A_2] 1082 >
<U4 [1] [Reroute_A_3] 1083 >
<U4 [1] [Reroute_A_4] 1084 >
<U4 [1] [Reroute_A_5] 1085 >
<U4 [1] [Reroute_B_1] 1086 >
<U4 [1] [Reroute_B_2] 1087 >
<U4 [1] [Reroute_B_3] 1088 >
<U4 [1] [Reroute_B_4] 1089 >
<U4 [1] [Reroute_B_5] 1090 >
<U4 [1] [Reroute_C_1] 1091 >
<U4 [1] [Reroute_C_2] 1092 >
<U4 [1] [Reroute_C_3] 1093 >
<U4 [1] [Reroute_C_4] 1094 >
<U4 [1] [Reroute_C_5] 1095 >
<U4 [1] [Reroute_D_1] 1096 >
<U4 [1] [Reroute_D_2] 1097 >
<U4 [1] [Reroute_D_3] 1098 >
<U4 [1] [Reroute_D_4] 1099 >
<U4 [1] [Reroute_D_5] 1100 >
>
>
<L [2]
<U4 [1] [reportid] 200041 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200042 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [UserName] 21012 >
<U4 [1] [PreviousUserName] 21013 >
>
>
<L [2]
<U4 [1] [reportid] 200052 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [SubstrateID] 1000 >
<U4 [1] [PPExecName] 72 >
>
>
<L [2]
<U4 [1] [reportid] 200055 >
<L [2]
<U4 [1] [Clock] 3 >
<U4 [1] [PPChangeName] 1011 >
>
>
<L [2]
<U4 [1] [reportid] 200061 >
<L [3]
<U4 [1] [Clock] 3 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
>
>
>
>
.
2023-01-10 13:05:07,058: S2F34 System Bytes=10
<B [1] [DRACK] '' 00 >
.
2023-01-10 13:05:07,567: S2F35 W System Bytes=11
<L [2]
<U4 [1] [DATAID] 0 >
<L [19]
<L [2]
<U4 [1] [CEID] 1 >
<L [1]
<U4 [1] [RPTID] 1 >
>
>
<L [2]
<U4 [1] [CEID] 2 >
<L [1]
<U4 [1] [RPTID] 2 >
>
>
<L [2]
<U4 [1] [CEID] 3 >
<L [1]
<U4 [1] [RPTID] 3 >
>
>
<L [2]
<U4 [1] [CEID] 11 >
<L [1]
<U4 [1] [RPTID] 11 >
>
>
<L [2]
<U4 [1] [CEID] 12 >
<L [1]
<U4 [1] [RPTID] 12 >
>
>
<L [2]
<U4 [1] [CEID] 21 >
<L [1]
<U4 [1] [RPTID] 21 >
>
>
<L [2]
<U4 [1] [CEID] 22 >
<L [1]
<U4 [1] [RPTID] 22 >
>
>
<L [2]
<U4 [1] [CEID] 23 >
<L [1]
<U4 [1] [RPTID] 23 >
>
>
<L [2]
<U4 [1] [CEID] 300011 >
<L [1]
<U4 [1] [RPTID] 200011 >
>
>
<L [2]
<U4 [1] [CEID] 300012 >
<L [1]
<U4 [1] [RPTID] 200012 >
>
>
<L [2]
<U4 [1] [CEID] 300013 >
<L [1]
<U4 [1] [RPTID] 200013 >
>
>
<L [2]
<U4 [1] [CEID] 300021 >
<L [1]
<U4 [1] [RPTID] 200021 >
>
>
<L [2]
<U4 [1] [CEID] 300022 >
<L [1]
<U4 [1] [RPTID] 200022 >
>
>
<L [2]
<U4 [1] [CEID] 300032 >
<L [1]
<U4 [1] [RPTID] 200032 >
>
>
<L [2]
<U4 [1] [CEID] 300041 >
<L [1]
<U4 [1] [RPTID] 200041 >
>
>
<L [2]
<U4 [1] [CEID] 300042 >
<L [1]
<U4 [1] [RPTID] 200042 >
>
>
<L [2]
<U4 [1] [CEID] 300052 >
<L [1]
<U4 [1] [RPTID] 200052 >
>
>
<L [2]
<U4 [1] [CEID] 300055 >
<L [1]
<U4 [1] [RPTID] 200055 >
>
>
<L [2]
<U4 [1] [CEID] 300061 >
<L [1]
<U4 [1] [RPTID] 200061 >
>
>
>
>
.
2023-01-10 13:05:07,601: S2F36 System Bytes=11
<B [1] [] '' 00 >
.
2023-01-10 13:05:08,109: S2F37 W System Bytes=12
<L [2]
<BOOLEAN [1] [CEED] T >
<L [19]
<U4 [1] [EquipmentOffline] 1 >
<U4 [1] [ControlStateLocal] 2 >
<U4 [1] [ControlStateRemote] 3 >
<U4 [1] [AlarmDetected] 11 >
<U4 [1] [AlarmCleared] 12 >
<U4 [1] [SpoolTransmitFailure] 21 >
<U4 [1] [SpoolingActivated] 22 >
<U4 [1] [SpoolingDeactivated] 23 >
<U4 [1] [Material_Received] 300011 >
<U4 [1] [Material_Removed] 300012 >
<U4 [1] [Material_Hold] 300013 >
<U4 [1] [Process_Start] 300021 >
<U4 [1] [Process_Finish] 300022 >
<U4 [1] [Slotlist] 300032 >
<U4 [1] [UserLoggedOn] 300041 >
<U4 [1] [UserLoggedOff] 300042 >
<U4 [1] [ProcessRecipeSelected] 300052 >
<U4 [1] [ProcessProgramChange] 300055 >
<U4 [1] [EquipmentStateChange] 300061 >
>
>
.
2023-01-10 13:05:08,145: S2F38 System Bytes=12
<B [1] [] '' 00 >
.
2023-01-10 13:05:08,654: S5F3 W System Bytes=13
<L [2]
<B [1] [ALED] '' 80 >
<U4 [1] [ALID] 0 >
>
.
2023-01-10 13:05:09,205: S2F43 W System Bytes=14
<L [2]
<L [2]
<U1 [1] [STRID] 5 >
<L [1]
<U1 [1] [] 1 >
>
>
<L [2]
<U1 [1] [STRID] 6 >
<L [1]
<U1 [1] [] 11 >
>
>
>
.
2023-01-10 13:05:09,235: S2F44 System Bytes=14
<L [2]
<B [1] [] '' 00 >
<L [0]
>
>
.
2023-01-10 13:05:09,744: S1F3 W System Bytes=15
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 13:05:09,781: S1F4 System Bytes=15
<L [10]
<A [24] [eventTimestamp] '2023-01-10T05:02:19.273Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 13:05:10,288: S5F5 W System Bytes=16
<L [0]
>
.
2023-01-10 13:05:10,338: S5F6 System Bytes=16
<L [135]
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4065 >
<A [31] [ALTX] 'CV2: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4067 >
<A [29] [ALTX] 'CV2: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4066 >
<A [29] [ALTX] 'CV2: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4069 >
<A [40] [ALTX] 'CV2: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4068 >
<A [30] [ALTX] 'CV2: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4070 >
<A [20] [ALTX] 'CV2: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4073 >
<A [21] [ALTX] 'CV2: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3004 >
<A [36] [ALTX] 'EDS: Estop left infeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3005 >
<A [38] [ALTX] 'EDS: Estop right infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3006 >
<A [39] [ALTX] 'EDS: Estop right outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3007 >
<A [40] [ALTX] 'EDS: Estop right infeed inside activexxx' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3001 >
<A [25] [ALTX] 'EDS: Estop cabinet active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3002 >
<A [37] [ALTX] 'EDS: Estop left infeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4086 >
<A [25] [ALTX] 'CV2: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3003 >
<A [38] [ALTX] 'EDS: Estop left outfeed outside active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3049 >
<A [38] [ALTX] 'EDS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4005 >
<A [43] [ALTX] 'CV2: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3048 >
<A [40] [ALTX] 'EDS: Safety fault feedback Estop circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4004 >
<A [25] [ALTX] 'CV2: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3051 >
<A [22] [ALTX] 'EDS: Error door left 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3050 >
<A [40] [ALTX] 'EDS: Safety fault feedback laser circuit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 4006 >
<A [31] [ALTX] 'CV2: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3053 >
<A [22] [ALTX] 'EDS: Error door left 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4001 >
<A [22] [ALTX] 'CV2: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3052 >
<A [22] [ALTX] 'EDS: Error door left 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3055 >
<A [23] [ALTX] 'EDS: Error door right 1' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4003 >
<A [38] [ALTX] 'CV2: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3054 >
<A [22] [ALTX] 'EDS: Error door left 4' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4002 >
<A [23] [ALTX] 'CV2: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3041 >
<A [18] [ALTX] 'EDS: Error chiller' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3040 >
<A [28] [ALTX] 'EDS: time out vacuum outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3043 >
<A [26] [ALTX] 'EDS: Error aspiration unit' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3042 >
<A [23] [ALTX] 'EDS: Error Flap outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3045 >
<A [29] [ALTX] 'EDS: Error drive align infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3044 >
<A [22] [ALTX] 'EDS: Error flap infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3047 >
<A [32] [ALTX] 'EDS: Error drive conveyor infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3046 >
<A [30] [ALTX] 'EDS: Error drive align outfeed' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 4010 >
<A [22] [ALTX] 'CV2: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3064 >
<A [60] [ALTX] 'EDS: laser commisiioning active // automatik mode prohibited' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3065 >
<A [42] [ALTX] 'EDS: Interface downstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3066 >
<A [40] [ALTX] 'EDS: Interface upstream life signal lost' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3067 >
<A [31] [ALTX] 'EDS: Interface downstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3068 >
<A [29] [ALTX] 'EDS: Interface upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3069 >
<A [41] [ALTX] 'EDS: gap sensor not free / transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3070 >
<A [20] [ALTX] 'EDS: HMI-PLC Timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3071 >
<A [33] [ALTX] 'EDS: Aligning axis not referenced' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3056 >
<A [23] [ALTX] 'EDS: Error door right 2' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3057 >
<A [23] [ALTX] 'EDS: Error door right 3' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3058 >
<A [23] [ALTX] 'EDS: Error door right 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3062 >
<A [33] [ALTX] 'EDS: Error drive conveyor outfeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3063 >
<A [50] [ALTX] 'EDS: Gripper free with data / glass not in gripper' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3019 >
<A [23] [ALTX] 'EDS: time out gripper 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1066 >
<A [29] [ALTX] 'CV1: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3018 >
<A [23] [ALTX] 'EDS: time out gripper 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1067 >
<A [29] [ALTX] 'CV1: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3017 >
<A [31] [ALTX] 'EDS: time out gripper Aligning2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3016 >
<A [31] [ALTX] 'EDS: time out gripper Aligning1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1065 >
<A [31] [ALTX] 'CV1: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3023 >
<A [30] [ALTX] 'EDS: time out gripper linear 1' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1070 >
<A [20] [ALTX] 'CV1: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3022 >
<A [23] [ALTX] 'EDS: time out gripper 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3021 >
<A [23] [ALTX] 'EDS: time out gripper 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1068 >
<A [30] [ALTX] 'CV1: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3020 >
<A [21] [ALTX] 'EDS: Fuse chiller NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1069 >
<A [40] [ALTX] 'CV1: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3011 >
<A [16] [ALTX] 'EDS: Laser error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3010 >
<A [31] [ALTX] 'EDS: Estop extern active active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3009 >
<A [41] [ALTX] 'EDS: Estop right outfeed inside activeyyy' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 3008 >
<A [37] [ALTX] 'EDS: Estop left outfeed inside active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3015 >
<A [29] [ALTX] 'EDS: Fuse cabinet cooling NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3501 >
<A [42] [ALTX] 'EDS: Automatic power measurement requested' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3014 >
<A [31] [ALTX] 'EDS: Overvoltage protection NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3013 >
<A [33] [ALTX] 'EDS: Communication with Laser NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3012 >
<A [34] [ALTX] 'EDS: Fuse Power supply Laser 1 NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3034 >
<A [37] [ALTX] 'EDS: time out conveyor lifting infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3035 >
<A [38] [ALTX] 'EDS: time out conveyor lifting outfeed' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3505 >
<A [52] [ALTX] 'EDS: Laser simulation mode active. No laser emission' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3032 >
<A [28] [ALTX] 'EDS: Fuse 24V peripheral NOK' >
>
<L [3]
<B [1] [ALCD] '' 06 >
<U4 [1] [ALID] 3506 >
<A [53] [ALTX] 'EDS: Aspiration settings too low. Beware of pollution' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3033 >
<A [23] [ALTX] 'EDS: Fuse 24V drive NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3038 >
<A [28] [ALTX] 'EDS: process stopped by user' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3039 >
<A [27] [ALTX] 'EDS: time out vacuum infeed' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1086 >
<A [25] [ALTX] 'CV1: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3036 >
<A [30] [ALTX] 'EDS: time out gripper ref glas' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3037 >
<A [36] [ALTX] 'EDS: error air pressure out of range' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3026 >
<A [30] [ALTX] 'EDS: time out gripper linear 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3027 >
<A [34] [ALTX] 'EDS: Fuse 24V Operator buttons NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3024 >
<A [30] [ALTX] 'EDS: air conditioning CA fault' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1073 >
<A [21] [ALTX] 'CV1: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3025 >
<A [30] [ALTX] 'EDS: time out gripper linear 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3030 >
<A [30] [ALTX] 'EDS: time out gripper linear 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3031 >
<A [31] [ALTX] 'EDS: Fuse 24V miscellaneous NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3028 >
<A [24] [ALTX] 'EDS: Fuse supply Asi NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3029 >
<A [21] [ALTX] 'EDS: Fuse 24V IPC NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2065 >
<A [31] [ALTX] 'SBS: Downstream life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2067 >
<A [29] [ALTX] 'SBS: Interface Upstream error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2066 >
<A [29] [ALTX] 'SBS: Upstream Life signal NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2069 >
<A [40] [ALTX] 'SBS: Gap sensor not free. Transfer error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2068 >
<A [30] [ALTX] 'SBS: Interface downstream erro' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2070 >
<A [20] [ALTX] 'SBS: HMI-PLC timeout' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2073 >
<A [21] [ALTX] 'SBS: Sequence stopped' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2017 >
<A [19] [ALTX] 'SBS: Error lift low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2016 >
<A [27] [ALTX] 'SBS: Error single centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2019 >
<A [17] [ALTX] 'SBS: Error vacuum' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2018 >
<A [18] [ALTX] 'SBS: Error lift up' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2002 >
<A [23] [ALTX] 'SBS: Estop right active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2003 >
<A [38] [ALTX] 'SBS: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 2001 >
<A [22] [ALTX] 'SBS: Estop Left active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2006 >
<A [18] [ALTX] 'SBS: Error Brush 2' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2007 >
<A [18] [ALTX] 'SBS: Error Brush 3' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2004 >
<A [25] [ALTX] 'SBS: Error conveyor drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2005 >
<A [19] [ALTX] 'SBS: Error Brush 1 ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2010 >
<A [22] [ALTX] 'SBS: Estop line active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2008 >
<A [18] [ALTX] 'SBS: Error Brush 4' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2009 >
<A [35] [ALTX] 'SBS: Error brush 1 linear movement ' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2014 >
<A [34] [ALTX] 'SBS: Error brush 4 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2015 >
<A [25] [ALTX] 'SBS: Error dual centering' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2012 >
<A [34] [ALTX] 'SBS: Error brush 2 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2013 >
<A [34] [ALTX] 'SBS: Error brush 3 linear movement' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 2086 >
<A [25] [ALTX] 'SBS: Timeout infeed error' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1010 >
<A [22] [ALTX] 'CV1: Estop Line active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1001 >
<A [22] [ALTX] 'CV1: Estop Left Active' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1003 >
<A [38] [ALTX] 'CV1: Safety fault feedback STO circuit' >
>
<L [3]
<B [1] [ALCD] '' 02 >
<U4 [1] [ALID] 1002 >
<A [23] [ALTX] 'CV1: EStop Right Active' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1005 >
<A [43] [ALTX] 'CV1: Data on positon without sensor signals' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1004 >
<A [25] [ALTX] 'CV1: Error Conveyor Drive' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 1006 >
<A [31] [ALTX] 'CV1: Glass present without data' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3072 >
<A [32] [ALTX] 'EDS: Fuse Drives 400V supply NOK' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3073 >
<A [38] [ALTX] 'EDS: SQ stopped by HMI => no PLC error' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3074 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 1 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3075 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 2 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3076 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 3 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3077 >
<A [40] [ALTX] 'EDS: Cooling water flow circuit 4 to low' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3078 >
<A [45] [ALTX] 'EDS: Aspiration flow ASP too low (upper head)' >
>
<L [3]
<B [1] [ALCD] '' 05 >
<U4 [1] [ALID] 3079 >
<A [45] [ALTX] 'EDS: Aspiration flow PHD too low (lower head)' >
>
>
.
2023-01-10 13:05:10,847: S7F19 W System Bytes=17
2023-01-10 13:05:10,900: S7F20 System Bytes=17
<L [8]
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
>
.
2023-01-10 13:05:11,406: S2F13 W System Bytes=0
<L [14]
<U4 [1] [EnableAlarmReportSend] 4 >
<U4 [1] [TimeFormat] 8 >
<U4 [1] [MaxTerminalMsgLength] 9 >
<U4 [1] [EstablishCommunicationsTimeout] 49 >
<U4 [1] [DefaultCommunicationState] 12 >
<U4 [1] [DefaultControlState] 15 >
<U4 [1] [DefaultOnlineSubState] 16 >
<U4 [1] [DefaultOfflineSubState] 17 >
<U4 [1] [EnableSpooling] 40 >
<U4 [1] [OverWriteSpool] 42 >
<U4 [1] [MaxSpoolMessages] 43 >
<U4 [1] [MaxSpoolTransmit] 44 >
<U4 [1] [MDLN] 1 >
<U4 [1] [SOFTREV] 2 >
>
.
2023-01-10 13:05:11,444: S2F14 System Bytes=18
<L [14]
<BOOLEAN [1] [EnableAlarmReportSend] T >
<U1 [1] [TimeFormat] 2 >
<U4 [1] [MaxTerminalMsgLength] 80 >
<I2 [1] [EstablishCommunicationsTimeout] 30 >
<U1 [1] [DefaultCommunicationState] 1 >
<U1 [1] [DefaultControlState] 5 >
<U1 [1] [DefaultOnlineSubState] 5 >
<U1 [1] [DefaultOfflineSubState] 2 >
<BOOLEAN [1] [EnableSpooling] T >
<BOOLEAN [1] [OverWriteSpool] T >
<U4 [1] [MaxSpoolMessages] 100000 >
<U4 [1] [MaxSpoolTransmit] 0 >
<L [0]
>
<L [0]
>
>
.
2023-01-10 13:05:11,954: S2F15 W System Bytes=19
<L [2]
<L [2]
<U4 [1] [DefaultControlState] 15 >
<U1 [1] [ECV] 5 >
>
<L [2]
<U4 [1] [DefaultOnlineSubState] 16 >
<U1 [1] [ECV] 5 >
>
>
.
2023-01-10 13:05:12,002: S2F16 System Bytes=19
<B [1] [] '' 00 >
.
2023-01-10 13:05:12,510: S1F15 W System Bytes=20
2023-01-10 13:05:12,546: S1F16 System Bytes=20
<B [1] [] '' 00 >
.
2023-01-10 13:05:12,548: S6F11 W System Bytes=691
<L [3]
<U4 [1] [] 73 >
<U4 [1] [] 1 >
<L [1]
<L [2]
<U4 [1] [] 1 >
<L [3]
<A [24] [Clock] '2023-01-10T05:02:22.037Z' >
<U1 [1] [CurrentControlState] 3 >
<U1 [1] [PreviousControlState] 5 >
>
>
>
>
.
2023-01-10 13:05:12,548: S6F12 W System Bytes=691
<B [1] [ACKC6] '' 00 >
.
2023-01-10 13:05:13,054: S1F17 W System Bytes=21
2023-01-10 13:05:13,085: S6F11 W System Bytes=692
<L [3]
<U4 [1] [] 74 >
<U4 [1] [] 3 >
<L [1]
<L [2]
<U4 [1] [] 3 >
<L [3]
<A [24] [Clock] '2023-01-10T05:02:22.581Z' >
<U1 [1] [CurrentControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
>
>
>
>
.
2023-01-10 13:05:13,088: S1F18 System Bytes=21
<B [1] [] '' 00 >
.
2023-01-10 13:05:13,088: S6F12 W System Bytes=692
<B [1] [ACKC6] '' 00 >
.
2023-01-10 13:05:13,592: S1F3 W System Bytes=22
<L [10]
<U4 [1] [Clock] 3 >
<U4 [1] [CommunicationState] 11 >
<U4 [1] [CurrentControlState] 13 >
<U4 [1] [PreviousControlState] 14 >
<U4 [1] [CurrentEquipmentState] 21010 >
<U4 [1] [PreviousEquipmentState] 21011 >
<U4 [1] [PPExecName] 72 >
<U4 [1] [SpoolingState] 41 >
<U4 [1] [SpoolCountActual] 45 >
<U4 [1] [SpoolCountTotal] 46 >
>
.
2023-01-10 13:05:13,630: S1F4 System Bytes=22
<L [10]
<A [24] [eventTimestamp] '2023-01-10T05:02:23.121Z' >
<U1 [1] [CommunicationState] 1 >
<U1 [1] [ControlState] 5 >
<U1 [1] [PreviousControlState] 3 >
<I2 [1] [CurrentEquipmentState] 2000 >
<I2 [1] [PreviousEquipmentState] 1000 >
<A [0] [PPExecName] '' >
<U1 [1] [SpoolingState] 0 >
<U4 [1] [SpoolCountActual] 0 >
<U4 [1] [SpoolCountTotal] 0 >
>
.
2023-01-10 13:05:14,147: S2F23 W System Bytes=23
<L [5]
<U4 [1] [TRID] 1 >
<A [6] [DSPER_hhmmss] '000010' >
<U4 [1] [TOTSMP] 0 >
<U4 [1] [REPGSZ] 1 >
<L [0]
>
>
.
2023-01-10 13:05:14,178: S2F24 System Bytes=23
<B [1] [] '' 00 >
.