This commit is contained in:
13118993771@163.com
2022-07-27 14:46:20 +08:00
parent 5e9d0f1e2d
commit b593a243a5
260 changed files with 88819 additions and 102277 deletions

View File

@@ -1,6 +1,6 @@
<?xml version="1.0" encoding="utf-8"?>
<Configuration xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<connectSetting name="ACOAT_01" deviceId="1" remoteIp="7.185.92.72" remotePort="5000" />
<connectSetting name="ACOAT_01" deviceId="0" remoteIp="192.168.2.100" remotePort="5000" />
<mQConnectionCfg HostName="mq.picaiba.com" VirtualHost="cigs" UserName="ypfqF66wKskKfpkpJdEmfrCMBVpAP98y" Password="g4NtT55HHzXECDig2BWLvtkZRfD8oiMT" Port="5672" ClientProvidedName="ACOAT_01">
<Exchange>ACOAT_01_Exchange</Exchange>
<Exchange_RTDB>cdte</Exchange_RTDB>
@@ -221,7 +221,7 @@
<string>PreviousControlState</string>
<string>CurrentEquipmentState</string>
<string>PreviousEquipmentState</string>
<string>PPExecName</string>
<!--<string>PPExecName</string>-->
<string>SpoolingState</string>
<string>SpoolCountActual</string>
<string>SpoolCountTotal</string>
@@ -262,7 +262,7 @@
<SV svid="20400" name="CurrentControlState" format="U1" min="1" max="5" defaultValue="5" description="Current State of the Control State Machine" />
<SV svid="20401" name="PreviousControlState" format="U1" min="1" max="5" defaultValue="5" description="pREVIOUS State of the Control State Machine" />
<SV svid="20500" name="EventsEnabled" format="L" description="List of all enabled Events" />
<SV svid="20600" name="PPExecName" format="A" description="The PPID of the currently selected Process Program" />
<!--<SV svid="20600" name="PPExecName" format="A" description="The PPID of the currently selected Process Program" />-->
<SV svid="20701" name="ProcessingState" format="U1" description="Current state of the Processing State Machine." />
<SV svid="20702" name="PreviousProcessingState" format="L" description="The previous processing state of the equipment. " />
<SV svid="20800" name="SpoolCountActual" format="U4" description="Number of messages actually stored in the spool area." />
@@ -276,14 +276,15 @@
<SV svid="21011" name="PreviousEquipmentState" format="U2" min="1000" max="6000" defaultValue="4000" description="Previous equipment state." />
<SV svid="21012" name="UserName" format="A" />
<SV svid="21013" name="PreviousUserName" format="A" />
<SV svid="21014" name="LoginState" format="Boolean" />
</svs>
<dvs>
<DV dvid="40000" name="SubstrateID" />
<DV dvid="40001" name="LocationID" />
<DV dvid="40002" name="MaterialStatus" />
<DV dvid="40003" name="StateFlag" />
<DV dvid="40004" name="PPChangeStatus" />
<DV dvid="40005" name="PPChangeName" />
<!--<DV dvid="40004" name="PPChangeStatus" />
<DV dvid="40005" name="PPChangeName" />-->
<DV dvid="40010" name="Target A" />
<DV dvid="40011" name="Target B" />
<DV dvid="40012" name="Target C" />
@@ -292,7 +293,7 @@
<DV dvid="40015" name="Reroute B" />
<DV dvid="40016" name="Reroute C" />
<DV dvid="40017" name="Reroute D" />
<DV dvid="41000" name="Data1" />
<!--<DV dvid="41000" name="Data1" />
<DV dvid="41002" name="Data2" format="U1" />
<DV dvid="41003" name="Data3" />
<DV dvid="41004" name="Data4" />
@@ -305,10 +306,10 @@
<DV dvid="25001" name="SourceLocation" />
<DV dvid="250120" name="PalletID" />
<DV dvid="250130" name="Grade" />
<DV dvid="250101" name="ContainerSlotMap" />
<DV dvid="250101" name="ContainerSlotMap" />-->
<DV dvid="26000" name="SlotList" />
<DV dvid="40006" name="ContainerID" />
<DV dvid="40007" name="SlotID" />
<!--<DV dvid="40006" name="ContainerID" />
<DV dvid="40007" name="SlotID" />-->
</dvs>
<events>
<EVENT ceid="1" name="EquipmentOffline" reportid="1">
@@ -318,10 +319,9 @@
<unsignedInt>20401</unsignedInt>
</validVariables>
</EVENT>
<EVENT ceid="2" name="ControlStateLocal" reportid="2">
<!--<EVENT ceid="2" name="ControlStateLocal" reportid="2">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
<unsignedInt>20400</unsignedInt>
<unsignedInt>20401</unsignedInt>
</validVariables>
@@ -329,15 +329,14 @@
<EVENT ceid="3" name="ControlStateRemote" reportid="3">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
<unsignedInt>20400</unsignedInt>
<unsignedInt>20401</unsignedInt>
</validVariables>
</EVENT>
</EVENT>-->
<EVENT ceid="11" name="AlarmDetected" reportid="11">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
<!--<unsignedInt>40003</unsignedInt>-->
<unsignedInt>20202</unsignedInt>
<unsignedInt>20203</unsignedInt>
<unsignedInt>20204</unsignedInt>
@@ -346,7 +345,7 @@
<EVENT ceid="12" name="AlarmCleared" reportid="12">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
<!--<unsignedInt>40003</unsignedInt>-->
<unsignedInt>20202</unsignedInt>
<unsignedInt>20203</unsignedInt>
<unsignedInt>20204</unsignedInt>
@@ -355,22 +354,20 @@
<EVENT ceid="21" name="SpoolTransmitFailure" reportid="21">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>20400</unsignedInt>
<unsignedInt>20405</unsignedInt>
<unsignedInt>20800</unsignedInt>
<unsignedInt>20804</unsignedInt>
</validVariables>
</EVENT>
<EVENT ceid="22" name="SpoolingActivated" reportid="22">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>20400</unsignedInt>
<unsignedInt>20406</unsignedInt>
<unsignedInt>20800</unsignedInt>
</validVariables>
</EVENT>
<EVENT ceid="23" name="SpoolingDeactivated" reportid="23">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>20400</unsignedInt>
<unsignedInt>20407</unsignedInt>
<unsignedInt>20800</unsignedInt>
</validVariables>
</EVENT>
<EVENT ceid="120" name="MaintenanceStart" reportid="120">
@@ -389,7 +386,7 @@
<unsignedInt>40003</unsignedInt>
<unsignedInt>40001</unsignedInt>
<unsignedInt>40000</unsignedInt>
<unsignedInt>20600</unsignedInt>
<!--<unsignedInt>20600</unsignedInt>-->
<unsignedInt>40002</unsignedInt>
</validVariables>
</EVENT>
@@ -410,7 +407,7 @@
<unsignedInt>40017</unsignedInt>
</validVariables>
</EVENT>
<EVENT ceid="300013" name="Material_Hold" reportid="200013">
<!--<EVENT ceid="300013" name="Material_Hold" reportid="200013">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
@@ -443,15 +440,15 @@
<unsignedInt>40016</unsignedInt>
<unsignedInt>40017</unsignedInt>
</validVariables>
</EVENT>
</EVENT>-->
<EVENT ceid="300021" name="Process_Start" reportid="200021">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
<unsignedInt>40000</unsignedInt>
<unsignedInt>20600</unsignedInt>
<!--<unsignedInt>20600</unsignedInt>
<unsignedInt>21010</unsignedInt>
<unsignedInt>21011</unsignedInt>
<unsignedInt>21011</unsignedInt>-->
</validVariables>
</EVENT>
<EVENT ceid="300022" name="Process_Finish" reportid="200022">
@@ -459,9 +456,9 @@
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
<unsignedInt>40000</unsignedInt>
<unsignedInt>20600</unsignedInt>
<unsignedInt>21010</unsignedInt>
<unsignedInt>21011</unsignedInt>
<!--unsignedInt>20600</unsignedInt>-->
<!--<unsignedInt>21010</unsignedInt>
<unsignedInt>21011</unsignedInt>-->
<unsignedInt>40002</unsignedInt>
<unsignedInt>41000</unsignedInt>
<unsignedInt>41002</unsignedInt>
@@ -483,9 +480,10 @@
<unsignedInt>20300</unsignedInt>
<unsignedInt>21012</unsignedInt>
<unsignedInt>21013</unsignedInt>
<unsignedInt>21014</unsignedInt>
</validVariables>
</EVENT>
<EVENT ceid="300042" name="UserLoggedOff" reportid="200042">
<!--<EVENT ceid="300042" name="UserLoggedOff" reportid="200042">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>21012</unsignedInt>
@@ -513,16 +511,16 @@
<unsignedInt>20400</unsignedInt>
<unsignedInt>20421</unsignedInt>
</validVariables>
</EVENT>
</EVENT>-->
<EVENT ceid="300061" name="EquipmentStateChange" reportid="200061">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
<!--<unsignedInt>40003</unsignedInt>-->
<unsignedInt>21010</unsignedInt>
<unsignedInt>21011</unsignedInt>
</validVariables>
</EVENT>
<EVENT ceid="300063" name="Machine_Data_1" reportid="200063">
<!--<EVENT ceid="300063" name="Machine_Data_1" reportid="200063">
<validVariables>
<unsignedInt>20300</unsignedInt>
<unsignedInt>40003</unsignedInt>
@@ -760,7 +758,7 @@
<unsignedInt>40016</unsignedInt>
<unsignedInt>40017</unsignedInt>
</validVariables>
</EVENT>
</EVENT>-->
</events>
</sRDConfiguration>
</Configuration>