9350 lines
232 KiB
Plaintext
9350 lines
232 KiB
Plaintext
2023-01-10 11:02:23,884 [RECV] S6F11 W System Bytes=420
|
|
<L [3]
|
|
<U4 [1] [] 25 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T02:59:33.429Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:02:23,893 [SEND] S6F12 W System Bytes=420
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:02:35,278 [RECV] S6F11 W System Bytes=421
|
|
<L [3]
|
|
<U4 [1] [] 26 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T02:59:44.821Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:02:35,286 [SEND] S6F12 W System Bytes=421
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:27,164 [RECV] S1F13 W System Bytes=424
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:27,169 [SEND] S1F13 W System Bytes=1
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:27,181 [SEND] S1F14 System Bytes=424
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:27,442 [RECV] S1F14 System Bytes=1
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:27,973 [SEND] S1F17 W System Bytes=2
|
|
|
|
2023-01-10 11:03:27,988 [RECV] S1F18 System Bytes=2
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:03:28,519 [SEND] S1F3 W System Bytes=3
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:28,536 [RECV] S1F4 System Bytes=3
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:00:38.084Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 4000 >
|
|
<I2 [1] [] 4000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 2 >
|
|
<U4 [1] [] 2 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,067 [SEND] S6F23 W System Bytes=4
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:03:29,083 [RECV] S6F24 System Bytes=4
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:29,143 [RECV] S6F11 W System Bytes=425
|
|
<L [3]
|
|
<U4 [1] [] 27 >
|
|
<U4 [1] [] 22 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 22 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:00:15.823Z' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<A [24] [] '2023-01-10T02:35:00.400Z' >
|
|
<A [24] [] '2023-01-10T02:35:00.400Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,159 [SEND] S6F12 W System Bytes=425
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:29,173 [RECV] S6F11 W System Bytes=426
|
|
<L [3]
|
|
<U4 [1] [] 28 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:00:32.395Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,179 [SEND] S6F12 W System Bytes=426
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:29,203 [RECV] S6F11 W System Bytes=427
|
|
<L [3]
|
|
<U4 [1] [] 29 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:00:38.747Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 2 >
|
|
<U4 [1] [] 2 >
|
|
<A [24] [] '2023-01-10T02:35:00.400Z' >
|
|
<A [24] [] '2023-01-10T03:00:15.821Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,218 [SEND] S6F12 W System Bytes=427
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:29,226 [SEND] S2F43 W System Bytes=5
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,278 [RECV] S6F11 W System Bytes=428
|
|
<L [3]
|
|
<U4 [1] [] 30 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:00:38.832Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 2 >
|
|
<U4 [1] [] 2 >
|
|
<A [24] [] '2023-01-10T02:35:00.400Z' >
|
|
<A [24] [] '2023-01-10T03:00:15.821Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,293 [SEND] S6F12 W System Bytes=428
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:29,308 [RECV] S2F44 System Bytes=5
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,836 [SEND] S2F37 W System Bytes=6
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:29,867 [RECV] S2F38 System Bytes=6
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:30,398 [SEND] S2F35 W System Bytes=7
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:30,413 [RECV] S2F36 System Bytes=7
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:30,942 [SEND] S2F33 W System Bytes=8
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:30,972 [RECV] S2F34 System Bytes=8
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:31,505 [SEND] S5F3 W System Bytes=9
|
|
<L [2]
|
|
<B [1] [ALED] '' 00 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:31,520 [RECV] S5F4 System Bytes=9
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:03:32,051 [SEND] S2F33 W System Bytes=10
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [reportid] 1 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 2 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 3 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 11 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 12 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 21 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 22 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 23 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200011 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200012 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200013 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200021 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200022 >
|
|
<L [16]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [ProcessResult] 1013 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [ProcessDurationSBS] 1015 >
|
|
<U4 [1] [ProcessDurationEDS] 1016 >
|
|
<U4 [1] [ProcessRecipeId] 1017 >
|
|
<U4 [1] [ProcessRecipeName] 1018 >
|
|
<U4 [1] [ProcessRecipeVersion] 1019 >
|
|
<U4 [1] [ProcessRecipeCreationDate] 1020 >
|
|
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
|
|
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
|
|
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
|
|
<U4 [1] [MeasuredSubstrateWidth] 1024 >
|
|
<U4 [1] [MeasuredSubstrateLength] 1025 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200032 >
|
|
<L [56]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID_CV1] 1046 >
|
|
<U4 [1] [SubstrateID_SBS] 1047 >
|
|
<U4 [1] [SubstrateID_EDS1] 1048 >
|
|
<U4 [1] [SubstrateID_EDS2] 1049 >
|
|
<U4 [1] [SubstrateID_CV2] 1050 >
|
|
<U4 [1] [LocationId_CV1] 1051 >
|
|
<U4 [1] [LocationId_SBS] 1052 >
|
|
<U4 [1] [LocationId_EDS1] 1053 >
|
|
<U4 [1] [LocationId_EDS2] 1054 >
|
|
<U4 [1] [LocationId_CV2] 1055 >
|
|
<U4 [1] [Slot1_CV1] 1056 >
|
|
<U4 [1] [Slot1_SBS] 1057 >
|
|
<U4 [1] [Slot1_EDS1] 1058 >
|
|
<U4 [1] [Slot1_EDS2] 1059 >
|
|
<U4 [1] [Slot1_CV2] 1060 >
|
|
<U4 [1] [Target_A_1] 1061 >
|
|
<U4 [1] [Target_A_2] 1062 >
|
|
<U4 [1] [Target_A_3] 1063 >
|
|
<U4 [1] [Target_A_4] 1064 >
|
|
<U4 [1] [Target_A_5] 1065 >
|
|
<U4 [1] [Target_B_1] 1066 >
|
|
<U4 [1] [Target_B_2] 1067 >
|
|
<U4 [1] [Target_B_3] 1068 >
|
|
<U4 [1] [Target_B_4] 1069 >
|
|
<U4 [1] [Target_B_5] 1070 >
|
|
<U4 [1] [Target_C_1] 1071 >
|
|
<U4 [1] [Target_C_2] 1072 >
|
|
<U4 [1] [Target_C_3] 1073 >
|
|
<U4 [1] [Target_C_4] 1074 >
|
|
<U4 [1] [Target_C_5] 1075 >
|
|
<U4 [1] [Target_D_1] 1076 >
|
|
<U4 [1] [Target_D_2] 1077 >
|
|
<U4 [1] [Target_D_3] 1078 >
|
|
<U4 [1] [Target_D_4] 1079 >
|
|
<U4 [1] [Target_D_5] 1080 >
|
|
<U4 [1] [Reroute_A_1] 1081 >
|
|
<U4 [1] [Reroute_A_2] 1082 >
|
|
<U4 [1] [Reroute_A_3] 1083 >
|
|
<U4 [1] [Reroute_A_4] 1084 >
|
|
<U4 [1] [Reroute_A_5] 1085 >
|
|
<U4 [1] [Reroute_B_1] 1086 >
|
|
<U4 [1] [Reroute_B_2] 1087 >
|
|
<U4 [1] [Reroute_B_3] 1088 >
|
|
<U4 [1] [Reroute_B_4] 1089 >
|
|
<U4 [1] [Reroute_B_5] 1090 >
|
|
<U4 [1] [Reroute_C_1] 1091 >
|
|
<U4 [1] [Reroute_C_2] 1092 >
|
|
<U4 [1] [Reroute_C_3] 1093 >
|
|
<U4 [1] [Reroute_C_4] 1094 >
|
|
<U4 [1] [Reroute_C_5] 1095 >
|
|
<U4 [1] [Reroute_D_1] 1096 >
|
|
<U4 [1] [Reroute_D_2] 1097 >
|
|
<U4 [1] [Reroute_D_3] 1098 >
|
|
<U4 [1] [Reroute_D_4] 1099 >
|
|
<U4 [1] [Reroute_D_5] 1100 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200041 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200042 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200052 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200055 >
|
|
<L [2]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [PPChangeName] 1011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200061 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:32,080 [RECV] S2F34 System Bytes=10
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:32,616 [SEND] S2F35 W System Bytes=11
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [CEID] 1 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 2 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 2 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 3 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 3 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 11 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 11 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 12 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 12 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 21 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 21 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 22 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 22 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 23 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 23 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300011 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300012 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200012 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300013 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300021 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200021 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300022 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200022 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300032 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200032 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300041 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200041 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300042 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200042 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300052 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200052 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300055 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200055 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300061 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200061 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:32,641 [RECV] S2F36 System Bytes=11
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:33,168 [SEND] S2F37 W System Bytes=12
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] T >
|
|
<L [19]
|
|
<U4 [1] [EquipmentOffline] 1 >
|
|
<U4 [1] [ControlStateLocal] 2 >
|
|
<U4 [1] [ControlStateRemote] 3 >
|
|
<U4 [1] [AlarmDetected] 11 >
|
|
<U4 [1] [AlarmCleared] 12 >
|
|
<U4 [1] [SpoolTransmitFailure] 21 >
|
|
<U4 [1] [SpoolingActivated] 22 >
|
|
<U4 [1] [SpoolingDeactivated] 23 >
|
|
<U4 [1] [Material_Received] 300011 >
|
|
<U4 [1] [Material_Removed] 300012 >
|
|
<U4 [1] [Material_Hold] 300013 >
|
|
<U4 [1] [Process_Start] 300021 >
|
|
<U4 [1] [Process_Finish] 300022 >
|
|
<U4 [1] [Slotlist] 300032 >
|
|
<U4 [1] [UserLoggedOn] 300041 >
|
|
<U4 [1] [UserLoggedOff] 300042 >
|
|
<U4 [1] [ProcessRecipeSelected] 300052 >
|
|
<U4 [1] [ProcessProgramChange] 300055 >
|
|
<U4 [1] [EquipmentStateChange] 300061 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:33,197 [RECV] S2F38 System Bytes=12
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:33,732 [SEND] S5F3 W System Bytes=13
|
|
<L [2]
|
|
<B [1] [ALED] '' 80 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:33,762 [RECV] S5F4 System Bytes=13
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:03:34,292 [SEND] S2F43 W System Bytes=14
|
|
<L [2]
|
|
<L [2]
|
|
<U1 [1] [STRID] 5 >
|
|
<L [1]
|
|
<U1 [1] [] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U1 [1] [STRID] 6 >
|
|
<L [1]
|
|
<U1 [1] [] 11 >
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:34,307 [RECV] S2F44 System Bytes=14
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:34,837 [SEND] S1F3 W System Bytes=15
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:34,867 [RECV] S1F4 System Bytes=15
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:00:44.400Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 4000 >
|
|
<I2 [1] [] 4000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:35,394 [SEND] S5F5 W System Bytes=16
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:35,425 [RECV] S5F6 System Bytes=16
|
|
<L [135]
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4065 >
|
|
<A [31] [] 'CV2: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4067 >
|
|
<A [29] [] 'CV2: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4066 >
|
|
<A [29] [] 'CV2: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4069 >
|
|
<A [40] [] 'CV2: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4068 >
|
|
<A [30] [] 'CV2: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4070 >
|
|
<A [20] [] 'CV2: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4073 >
|
|
<A [21] [] 'CV2: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3004 >
|
|
<A [36] [] 'EDS: Estop left infeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3005 >
|
|
<A [38] [] 'EDS: Estop right infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3006 >
|
|
<A [39] [] 'EDS: Estop right outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3007 >
|
|
<A [40] [] 'EDS: Estop right infeed inside activexxx' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3001 >
|
|
<A [25] [] 'EDS: Estop cabinet active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3002 >
|
|
<A [37] [] 'EDS: Estop left infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4086 >
|
|
<A [25] [] 'CV2: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3003 >
|
|
<A [38] [] 'EDS: Estop left outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3049 >
|
|
<A [38] [] 'EDS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4005 >
|
|
<A [43] [] 'CV2: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3048 >
|
|
<A [40] [] 'EDS: Safety fault feedback Estop circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4004 >
|
|
<A [25] [] 'CV2: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3051 >
|
|
<A [22] [] 'EDS: Error door left 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3050 >
|
|
<A [40] [] 'EDS: Safety fault feedback laser circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4006 >
|
|
<A [31] [] 'CV2: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3053 >
|
|
<A [22] [] 'EDS: Error door left 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4001 >
|
|
<A [22] [] 'CV2: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3052 >
|
|
<A [22] [] 'EDS: Error door left 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3055 >
|
|
<A [23] [] 'EDS: Error door right 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4003 >
|
|
<A [38] [] 'CV2: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3054 >
|
|
<A [22] [] 'EDS: Error door left 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4002 >
|
|
<A [23] [] 'CV2: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3041 >
|
|
<A [18] [] 'EDS: Error chiller' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3040 >
|
|
<A [28] [] 'EDS: time out vacuum outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3043 >
|
|
<A [26] [] 'EDS: Error aspiration unit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3042 >
|
|
<A [23] [] 'EDS: Error Flap outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3045 >
|
|
<A [29] [] 'EDS: Error drive align infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3044 >
|
|
<A [22] [] 'EDS: Error flap infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3047 >
|
|
<A [32] [] 'EDS: Error drive conveyor infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3046 >
|
|
<A [30] [] 'EDS: Error drive align outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4010 >
|
|
<A [22] [] 'CV2: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3064 >
|
|
<A [60] [] 'EDS: laser commisiioning active // automatik mode prohibited' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3065 >
|
|
<A [42] [] 'EDS: Interface downstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3066 >
|
|
<A [40] [] 'EDS: Interface upstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3067 >
|
|
<A [31] [] 'EDS: Interface downstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3068 >
|
|
<A [29] [] 'EDS: Interface upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3069 >
|
|
<A [41] [] 'EDS: gap sensor not free / transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3070 >
|
|
<A [20] [] 'EDS: HMI-PLC Timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3071 >
|
|
<A [33] [] 'EDS: Aligning axis not referenced' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3056 >
|
|
<A [23] [] 'EDS: Error door right 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3057 >
|
|
<A [23] [] 'EDS: Error door right 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3058 >
|
|
<A [23] [] 'EDS: Error door right 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3062 >
|
|
<A [33] [] 'EDS: Error drive conveyor outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3063 >
|
|
<A [50] [] 'EDS: Gripper free with data / glass not in gripper' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3019 >
|
|
<A [23] [] 'EDS: time out gripper 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1066 >
|
|
<A [29] [] 'CV1: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3018 >
|
|
<A [23] [] 'EDS: time out gripper 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1067 >
|
|
<A [29] [] 'CV1: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3017 >
|
|
<A [31] [] 'EDS: time out gripper Aligning2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3016 >
|
|
<A [31] [] 'EDS: time out gripper Aligning1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1065 >
|
|
<A [31] [] 'CV1: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3023 >
|
|
<A [30] [] 'EDS: time out gripper linear 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1070 >
|
|
<A [20] [] 'CV1: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3022 >
|
|
<A [23] [] 'EDS: time out gripper 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3021 >
|
|
<A [23] [] 'EDS: time out gripper 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1068 >
|
|
<A [30] [] 'CV1: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3020 >
|
|
<A [21] [] 'EDS: Fuse chiller NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1069 >
|
|
<A [40] [] 'CV1: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3011 >
|
|
<A [16] [] 'EDS: Laser error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3010 >
|
|
<A [31] [] 'EDS: Estop extern active active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3009 >
|
|
<A [41] [] 'EDS: Estop right outfeed inside activeyyy' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3008 >
|
|
<A [37] [] 'EDS: Estop left outfeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3015 >
|
|
<A [29] [] 'EDS: Fuse cabinet cooling NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3501 >
|
|
<A [42] [] 'EDS: Automatic power measurement requested' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3014 >
|
|
<A [31] [] 'EDS: Overvoltage protection NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3013 >
|
|
<A [33] [] 'EDS: Communication with Laser NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3012 >
|
|
<A [34] [] 'EDS: Fuse Power supply Laser 1 NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3034 >
|
|
<A [37] [] 'EDS: time out conveyor lifting infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3035 >
|
|
<A [38] [] 'EDS: time out conveyor lifting outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3505 >
|
|
<A [52] [] 'EDS: Laser simulation mode active. No laser emission' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3032 >
|
|
<A [28] [] 'EDS: Fuse 24V peripheral NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3506 >
|
|
<A [53] [] 'EDS: Aspiration settings too low. Beware of pollution' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3033 >
|
|
<A [23] [] 'EDS: Fuse 24V drive NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3038 >
|
|
<A [28] [] 'EDS: process stopped by user' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3039 >
|
|
<A [27] [] 'EDS: time out vacuum infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1086 >
|
|
<A [25] [] 'CV1: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3036 >
|
|
<A [30] [] 'EDS: time out gripper ref glas' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3037 >
|
|
<A [36] [] 'EDS: error air pressure out of range' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3026 >
|
|
<A [30] [] 'EDS: time out gripper linear 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3027 >
|
|
<A [34] [] 'EDS: Fuse 24V Operator buttons NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3024 >
|
|
<A [30] [] 'EDS: air conditioning CA fault' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1073 >
|
|
<A [21] [] 'CV1: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3025 >
|
|
<A [30] [] 'EDS: time out gripper linear 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3030 >
|
|
<A [30] [] 'EDS: time out gripper linear 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3031 >
|
|
<A [31] [] 'EDS: Fuse 24V miscellaneous NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3028 >
|
|
<A [24] [] 'EDS: Fuse supply Asi NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3029 >
|
|
<A [21] [] 'EDS: Fuse 24V IPC NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2065 >
|
|
<A [31] [] 'SBS: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2067 >
|
|
<A [29] [] 'SBS: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2066 >
|
|
<A [29] [] 'SBS: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2069 >
|
|
<A [40] [] 'SBS: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2068 >
|
|
<A [30] [] 'SBS: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2070 >
|
|
<A [20] [] 'SBS: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2073 >
|
|
<A [21] [] 'SBS: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2017 >
|
|
<A [19] [] 'SBS: Error lift low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2016 >
|
|
<A [27] [] 'SBS: Error single centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2019 >
|
|
<A [17] [] 'SBS: Error vacuum' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2018 >
|
|
<A [18] [] 'SBS: Error lift up' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2002 >
|
|
<A [23] [] 'SBS: Estop right active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2003 >
|
|
<A [38] [] 'SBS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2001 >
|
|
<A [22] [] 'SBS: Estop Left active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2006 >
|
|
<A [18] [] 'SBS: Error Brush 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2007 >
|
|
<A [18] [] 'SBS: Error Brush 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2004 >
|
|
<A [25] [] 'SBS: Error conveyor drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2005 >
|
|
<A [19] [] 'SBS: Error Brush 1 ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2010 >
|
|
<A [22] [] 'SBS: Estop line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2008 >
|
|
<A [18] [] 'SBS: Error Brush 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2009 >
|
|
<A [35] [] 'SBS: Error brush 1 linear movement ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2014 >
|
|
<A [34] [] 'SBS: Error brush 4 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2015 >
|
|
<A [25] [] 'SBS: Error dual centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2012 >
|
|
<A [34] [] 'SBS: Error brush 2 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2013 >
|
|
<A [34] [] 'SBS: Error brush 3 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2086 >
|
|
<A [25] [] 'SBS: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1010 >
|
|
<A [22] [] 'CV1: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1001 >
|
|
<A [22] [] 'CV1: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1003 >
|
|
<A [38] [] 'CV1: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1002 >
|
|
<A [23] [] 'CV1: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1005 >
|
|
<A [43] [] 'CV1: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1004 >
|
|
<A [25] [] 'CV1: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1006 >
|
|
<A [31] [] 'CV1: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3072 >
|
|
<A [32] [] 'EDS: Fuse Drives 400V supply NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3073 >
|
|
<A [38] [] 'EDS: SQ stopped by HMI => no PLC error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3074 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 1 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3075 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 2 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3076 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 3 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3077 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 4 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3078 >
|
|
<A [45] [] 'EDS: Aspiration flow ASP too low (upper head)' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3079 >
|
|
<A [45] [] 'EDS: Aspiration flow PHD too low (lower head)' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:35,957 [SEND] S7F19 W System Bytes=17
|
|
|
|
2023-01-10 11:03:35,972 [RECV] S7F20 System Bytes=17
|
|
<L [8]
|
|
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
|
|
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:36,500 [SEND] S2F13 W System Bytes=18
|
|
<L [14]
|
|
<U4 [1] [EnableAlarmReportSend] 4 >
|
|
<U4 [1] [TimeFormat] 8 >
|
|
<U4 [1] [MaxTerminalMsgLength] 9 >
|
|
<U4 [1] [EstablishCommunicationsTimeout] 49 >
|
|
<U4 [1] [DefaultCommunicationState] 12 >
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U4 [1] [DefaultOfflineSubState] 17 >
|
|
<U4 [1] [EnableSpooling] 40 >
|
|
<U4 [1] [OverWriteSpool] 42 >
|
|
<U4 [1] [MaxSpoolMessages] 43 >
|
|
<U4 [1] [MaxSpoolTransmit] 44 >
|
|
<U4 [1] [MDLN] 1 >
|
|
<U4 [1] [SOFTREV] 2 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:36,530 [RECV] S2F14 System Bytes=18
|
|
<L [14]
|
|
<BOOLEAN [1] [] T >
|
|
<U1 [1] [] 2 >
|
|
<U4 [1] [] 80 >
|
|
<I2 [1] [] 30 >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 2 >
|
|
<BOOLEAN [1] [] T >
|
|
<BOOLEAN [1] [] T >
|
|
<U4 [1] [] 100000 >
|
|
<U4 [1] [] 0 >
|
|
<L [0]
|
|
>
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:37,056 [SEND] S2F15 W System Bytes=19
|
|
<L [2]
|
|
<L [2]
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
<L [2]
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:37,071 [RECV] S2F16 System Bytes=19
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:37,610 [SEND] S1F15 W System Bytes=20
|
|
|
|
2023-01-10 11:03:37,625 [RECV] S1F16 System Bytes=20
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:37,631 [RECV] S6F11 W System Bytes=429
|
|
<L [3]
|
|
<U4 [1] [] 31 >
|
|
<U4 [1] [] 1 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 1 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:00:47.175Z' >
|
|
<U1 [1] [] 3 >
|
|
<U1 [1] [] 5 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:37,634 [SEND] S6F12 W System Bytes=429
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:38,155 [SEND] S1F17 W System Bytes=21
|
|
|
|
2023-01-10 11:03:38,170 [RECV] S6F11 W System Bytes=430
|
|
<L [3]
|
|
<U4 [1] [] 32 >
|
|
<U4 [1] [] 3 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 3 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:00:47.719Z' >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:38,171 [RECV] S1F18 System Bytes=21
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:38,178 [SEND] S6F12 W System Bytes=430
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:38,712 [SEND] S1F3 W System Bytes=22
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:38,727 [RECV] S1F4 System Bytes=22
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:00:48.275Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 4000 >
|
|
<I2 [1] [] 4000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:39,260 [SEND] S2F23 W System Bytes=23
|
|
<L [5]
|
|
<U4 [1] [TRID] 1 >
|
|
<A [6] [DSPER_hhmmss] '000010' >
|
|
<U4 [1] [TOTSMP] 0 >
|
|
<U4 [1] [REPGSZ] 1 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:39,275 [RECV] S2F24 System Bytes=23
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:03:41,462 [RECV] S6F11 W System Bytes=431
|
|
<L [3]
|
|
<U4 [1] [] 33 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:00:51.012Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:03:41,468 [SEND] S6F12 W System Bytes=431
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:04:13,399 [RECV] S6F11 W System Bytes=433
|
|
<L [3]
|
|
<U4 [1] [] 34 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:01:22.943Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:04:13,407 [SEND] S6F12 W System Bytes=433
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:04:28,012 [RECV] S6F11 W System Bytes=434
|
|
<L [3]
|
|
<U4 [1] [] 35 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:01:37.562Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:04:28,027 [SEND] S6F12 W System Bytes=434
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:04:39,635 [RECV] S6F11 W System Bytes=436
|
|
<L [3]
|
|
<U4 [1] [] 36 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:01:49.179Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:04:39,650 [SEND] S6F12 W System Bytes=436
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:04:43,535 [RECV] S6F11 W System Bytes=437
|
|
<L [3]
|
|
<U4 [1] [] 37 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:01:53.081Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:04:43,550 [SEND] S6F12 W System Bytes=437
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:05:27,396 [RECV] S6F11 W System Bytes=439
|
|
<L [3]
|
|
<U4 [1] [] 38 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:02:36.942Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:05:27,411 [SEND] S6F12 W System Bytes=439
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:05:40,233 [RECV] S6F11 W System Bytes=441
|
|
<L [3]
|
|
<U4 [1] [] 39 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:02:49.772Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:05:40,248 [SEND] S6F12 W System Bytes=441
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:06:03,802 [RECV] S6F11 W System Bytes=443
|
|
<L [3]
|
|
<U4 [1] [] 40 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:03:13.342Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:06:03,816 [SEND] S6F12 W System Bytes=443
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:06:10,973 [RECV] S6F11 W System Bytes=444
|
|
<L [3]
|
|
<U4 [1] [] 41 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:03:20.506Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:06:10,988 [SEND] S6F12 W System Bytes=444
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:21,148 [SEND] S1F13 W System Bytes=1
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:21,177 [RECV] S1F13 W System Bytes=449
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:21,190 [SEND] S1F14 System Bytes=449
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:21,413 [RECV] S1F14 System Bytes=1
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:21,941 [SEND] S1F17 W System Bytes=2
|
|
|
|
2023-01-10 11:08:21,956 [RECV] S1F18 System Bytes=2
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:08:22,481 [SEND] S1F3 W System Bytes=3
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:22,498 [RECV] S1F4 System Bytes=3
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:05:32.046Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 4000 >
|
|
<I2 [1] [] 4000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:23,026 [SEND] S6F23 W System Bytes=4
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:08:23,041 [RECV] S6F24 System Bytes=4
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:23,100 [RECV] S6F11 W System Bytes=450
|
|
<L [3]
|
|
<U4 [1] [] 42 >
|
|
<U4 [1] [] 22 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 22 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:05:09.928Z' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<A [24] [] '2023-01-10T03:00:38.830Z' >
|
|
<A [24] [] '2023-01-10T03:00:38.830Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:23,116 [SEND] S6F12 W System Bytes=450
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:23,131 [RECV] S6F11 W System Bytes=451
|
|
<L [3]
|
|
<U4 [1] [] 43 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:05:32.680Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:00:38.830Z' >
|
|
<A [24] [] '2023-01-10T03:05:09.926Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:23,146 [SEND] S6F12 W System Bytes=451
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:23,152 [SEND] S2F43 W System Bytes=5
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:23,206 [RECV] S6F11 W System Bytes=452
|
|
<L [3]
|
|
<U4 [1] [] 44 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:05:32.754Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:00:38.830Z' >
|
|
<A [24] [] '2023-01-10T03:05:09.926Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:23,221 [SEND] S6F12 W System Bytes=452
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:23,236 [RECV] S2F44 System Bytes=5
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:23,765 [SEND] S2F37 W System Bytes=6
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:23,793 [RECV] S2F38 System Bytes=6
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:24,321 [SEND] S2F35 W System Bytes=7
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:24,336 [RECV] S2F36 System Bytes=7
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:24,867 [SEND] S2F33 W System Bytes=8
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:24,898 [RECV] S2F34 System Bytes=8
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:25,428 [SEND] S5F3 W System Bytes=9
|
|
<L [2]
|
|
<B [1] [ALED] '' 00 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:25,444 [RECV] S5F4 System Bytes=9
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:08:25,976 [SEND] S2F33 W System Bytes=10
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [reportid] 1 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 2 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 3 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 11 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 12 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 21 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 22 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 23 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200011 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200012 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200013 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200021 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200022 >
|
|
<L [16]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [ProcessResult] 1013 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [ProcessDurationSBS] 1015 >
|
|
<U4 [1] [ProcessDurationEDS] 1016 >
|
|
<U4 [1] [ProcessRecipeId] 1017 >
|
|
<U4 [1] [ProcessRecipeName] 1018 >
|
|
<U4 [1] [ProcessRecipeVersion] 1019 >
|
|
<U4 [1] [ProcessRecipeCreationDate] 1020 >
|
|
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
|
|
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
|
|
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
|
|
<U4 [1] [MeasuredSubstrateWidth] 1024 >
|
|
<U4 [1] [MeasuredSubstrateLength] 1025 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200032 >
|
|
<L [56]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID_CV1] 1046 >
|
|
<U4 [1] [SubstrateID_SBS] 1047 >
|
|
<U4 [1] [SubstrateID_EDS1] 1048 >
|
|
<U4 [1] [SubstrateID_EDS2] 1049 >
|
|
<U4 [1] [SubstrateID_CV2] 1050 >
|
|
<U4 [1] [LocationId_CV1] 1051 >
|
|
<U4 [1] [LocationId_SBS] 1052 >
|
|
<U4 [1] [LocationId_EDS1] 1053 >
|
|
<U4 [1] [LocationId_EDS2] 1054 >
|
|
<U4 [1] [LocationId_CV2] 1055 >
|
|
<U4 [1] [Slot1_CV1] 1056 >
|
|
<U4 [1] [Slot1_SBS] 1057 >
|
|
<U4 [1] [Slot1_EDS1] 1058 >
|
|
<U4 [1] [Slot1_EDS2] 1059 >
|
|
<U4 [1] [Slot1_CV2] 1060 >
|
|
<U4 [1] [Target_A_1] 1061 >
|
|
<U4 [1] [Target_A_2] 1062 >
|
|
<U4 [1] [Target_A_3] 1063 >
|
|
<U4 [1] [Target_A_4] 1064 >
|
|
<U4 [1] [Target_A_5] 1065 >
|
|
<U4 [1] [Target_B_1] 1066 >
|
|
<U4 [1] [Target_B_2] 1067 >
|
|
<U4 [1] [Target_B_3] 1068 >
|
|
<U4 [1] [Target_B_4] 1069 >
|
|
<U4 [1] [Target_B_5] 1070 >
|
|
<U4 [1] [Target_C_1] 1071 >
|
|
<U4 [1] [Target_C_2] 1072 >
|
|
<U4 [1] [Target_C_3] 1073 >
|
|
<U4 [1] [Target_C_4] 1074 >
|
|
<U4 [1] [Target_C_5] 1075 >
|
|
<U4 [1] [Target_D_1] 1076 >
|
|
<U4 [1] [Target_D_2] 1077 >
|
|
<U4 [1] [Target_D_3] 1078 >
|
|
<U4 [1] [Target_D_4] 1079 >
|
|
<U4 [1] [Target_D_5] 1080 >
|
|
<U4 [1] [Reroute_A_1] 1081 >
|
|
<U4 [1] [Reroute_A_2] 1082 >
|
|
<U4 [1] [Reroute_A_3] 1083 >
|
|
<U4 [1] [Reroute_A_4] 1084 >
|
|
<U4 [1] [Reroute_A_5] 1085 >
|
|
<U4 [1] [Reroute_B_1] 1086 >
|
|
<U4 [1] [Reroute_B_2] 1087 >
|
|
<U4 [1] [Reroute_B_3] 1088 >
|
|
<U4 [1] [Reroute_B_4] 1089 >
|
|
<U4 [1] [Reroute_B_5] 1090 >
|
|
<U4 [1] [Reroute_C_1] 1091 >
|
|
<U4 [1] [Reroute_C_2] 1092 >
|
|
<U4 [1] [Reroute_C_3] 1093 >
|
|
<U4 [1] [Reroute_C_4] 1094 >
|
|
<U4 [1] [Reroute_C_5] 1095 >
|
|
<U4 [1] [Reroute_D_1] 1096 >
|
|
<U4 [1] [Reroute_D_2] 1097 >
|
|
<U4 [1] [Reroute_D_3] 1098 >
|
|
<U4 [1] [Reroute_D_4] 1099 >
|
|
<U4 [1] [Reroute_D_5] 1100 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200041 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200042 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200052 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200055 >
|
|
<L [2]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [PPChangeName] 1011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200061 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:26,006 [RECV] S2F34 System Bytes=10
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:26,532 [SEND] S2F35 W System Bytes=11
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [CEID] 1 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 2 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 2 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 3 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 3 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 11 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 11 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 12 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 12 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 21 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 21 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 22 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 22 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 23 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 23 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300011 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300012 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200012 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300013 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300021 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200021 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300022 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200022 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300032 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200032 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300041 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200041 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300042 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200042 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300052 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200052 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300055 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200055 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300061 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200061 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:26,562 [RECV] S2F36 System Bytes=11
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:27,095 [SEND] S2F37 W System Bytes=12
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] T >
|
|
<L [19]
|
|
<U4 [1] [EquipmentOffline] 1 >
|
|
<U4 [1] [ControlStateLocal] 2 >
|
|
<U4 [1] [ControlStateRemote] 3 >
|
|
<U4 [1] [AlarmDetected] 11 >
|
|
<U4 [1] [AlarmCleared] 12 >
|
|
<U4 [1] [SpoolTransmitFailure] 21 >
|
|
<U4 [1] [SpoolingActivated] 22 >
|
|
<U4 [1] [SpoolingDeactivated] 23 >
|
|
<U4 [1] [Material_Received] 300011 >
|
|
<U4 [1] [Material_Removed] 300012 >
|
|
<U4 [1] [Material_Hold] 300013 >
|
|
<U4 [1] [Process_Start] 300021 >
|
|
<U4 [1] [Process_Finish] 300022 >
|
|
<U4 [1] [Slotlist] 300032 >
|
|
<U4 [1] [UserLoggedOn] 300041 >
|
|
<U4 [1] [UserLoggedOff] 300042 >
|
|
<U4 [1] [ProcessRecipeSelected] 300052 >
|
|
<U4 [1] [ProcessProgramChange] 300055 >
|
|
<U4 [1] [EquipmentStateChange] 300061 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:27,125 [RECV] S2F38 System Bytes=12
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:27,654 [SEND] S5F3 W System Bytes=13
|
|
<L [2]
|
|
<B [1] [ALED] '' 80 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:27,684 [RECV] S5F4 System Bytes=13
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:08:28,214 [SEND] S2F43 W System Bytes=14
|
|
<L [2]
|
|
<L [2]
|
|
<U1 [1] [STRID] 5 >
|
|
<L [1]
|
|
<U1 [1] [] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U1 [1] [STRID] 6 >
|
|
<L [1]
|
|
<U1 [1] [] 11 >
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:28,229 [RECV] S2F44 System Bytes=14
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:28,759 [SEND] S1F3 W System Bytes=15
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:28,774 [RECV] S1F4 System Bytes=15
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:05:38.320Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 4000 >
|
|
<I2 [1] [] 4000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:29,308 [SEND] S5F5 W System Bytes=16
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:29,341 [RECV] S5F6 System Bytes=16
|
|
<L [135]
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4065 >
|
|
<A [31] [] 'CV2: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4067 >
|
|
<A [29] [] 'CV2: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4066 >
|
|
<A [29] [] 'CV2: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4069 >
|
|
<A [40] [] 'CV2: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4068 >
|
|
<A [30] [] 'CV2: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4070 >
|
|
<A [20] [] 'CV2: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4073 >
|
|
<A [21] [] 'CV2: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3004 >
|
|
<A [36] [] 'EDS: Estop left infeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3005 >
|
|
<A [38] [] 'EDS: Estop right infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3006 >
|
|
<A [39] [] 'EDS: Estop right outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3007 >
|
|
<A [40] [] 'EDS: Estop right infeed inside activexxx' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3001 >
|
|
<A [25] [] 'EDS: Estop cabinet active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3002 >
|
|
<A [37] [] 'EDS: Estop left infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4086 >
|
|
<A [25] [] 'CV2: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3003 >
|
|
<A [38] [] 'EDS: Estop left outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3049 >
|
|
<A [38] [] 'EDS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4005 >
|
|
<A [43] [] 'CV2: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3048 >
|
|
<A [40] [] 'EDS: Safety fault feedback Estop circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4004 >
|
|
<A [25] [] 'CV2: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3051 >
|
|
<A [22] [] 'EDS: Error door left 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3050 >
|
|
<A [40] [] 'EDS: Safety fault feedback laser circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4006 >
|
|
<A [31] [] 'CV2: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3053 >
|
|
<A [22] [] 'EDS: Error door left 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4001 >
|
|
<A [22] [] 'CV2: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3052 >
|
|
<A [22] [] 'EDS: Error door left 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3055 >
|
|
<A [23] [] 'EDS: Error door right 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4003 >
|
|
<A [38] [] 'CV2: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3054 >
|
|
<A [22] [] 'EDS: Error door left 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4002 >
|
|
<A [23] [] 'CV2: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3041 >
|
|
<A [18] [] 'EDS: Error chiller' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3040 >
|
|
<A [28] [] 'EDS: time out vacuum outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3043 >
|
|
<A [26] [] 'EDS: Error aspiration unit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3042 >
|
|
<A [23] [] 'EDS: Error Flap outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3045 >
|
|
<A [29] [] 'EDS: Error drive align infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3044 >
|
|
<A [22] [] 'EDS: Error flap infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3047 >
|
|
<A [32] [] 'EDS: Error drive conveyor infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3046 >
|
|
<A [30] [] 'EDS: Error drive align outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4010 >
|
|
<A [22] [] 'CV2: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3064 >
|
|
<A [60] [] 'EDS: laser commisiioning active // automatik mode prohibited' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3065 >
|
|
<A [42] [] 'EDS: Interface downstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3066 >
|
|
<A [40] [] 'EDS: Interface upstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3067 >
|
|
<A [31] [] 'EDS: Interface downstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3068 >
|
|
<A [29] [] 'EDS: Interface upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3069 >
|
|
<A [41] [] 'EDS: gap sensor not free / transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3070 >
|
|
<A [20] [] 'EDS: HMI-PLC Timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3071 >
|
|
<A [33] [] 'EDS: Aligning axis not referenced' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3056 >
|
|
<A [23] [] 'EDS: Error door right 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3057 >
|
|
<A [23] [] 'EDS: Error door right 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3058 >
|
|
<A [23] [] 'EDS: Error door right 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3062 >
|
|
<A [33] [] 'EDS: Error drive conveyor outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3063 >
|
|
<A [50] [] 'EDS: Gripper free with data / glass not in gripper' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3019 >
|
|
<A [23] [] 'EDS: time out gripper 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1066 >
|
|
<A [29] [] 'CV1: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3018 >
|
|
<A [23] [] 'EDS: time out gripper 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1067 >
|
|
<A [29] [] 'CV1: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3017 >
|
|
<A [31] [] 'EDS: time out gripper Aligning2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3016 >
|
|
<A [31] [] 'EDS: time out gripper Aligning1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1065 >
|
|
<A [31] [] 'CV1: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3023 >
|
|
<A [30] [] 'EDS: time out gripper linear 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1070 >
|
|
<A [20] [] 'CV1: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3022 >
|
|
<A [23] [] 'EDS: time out gripper 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3021 >
|
|
<A [23] [] 'EDS: time out gripper 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1068 >
|
|
<A [30] [] 'CV1: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3020 >
|
|
<A [21] [] 'EDS: Fuse chiller NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1069 >
|
|
<A [40] [] 'CV1: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3011 >
|
|
<A [16] [] 'EDS: Laser error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3010 >
|
|
<A [31] [] 'EDS: Estop extern active active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3009 >
|
|
<A [41] [] 'EDS: Estop right outfeed inside activeyyy' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3008 >
|
|
<A [37] [] 'EDS: Estop left outfeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3015 >
|
|
<A [29] [] 'EDS: Fuse cabinet cooling NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3501 >
|
|
<A [42] [] 'EDS: Automatic power measurement requested' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3014 >
|
|
<A [31] [] 'EDS: Overvoltage protection NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3013 >
|
|
<A [33] [] 'EDS: Communication with Laser NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3012 >
|
|
<A [34] [] 'EDS: Fuse Power supply Laser 1 NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3034 >
|
|
<A [37] [] 'EDS: time out conveyor lifting infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3035 >
|
|
<A [38] [] 'EDS: time out conveyor lifting outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3505 >
|
|
<A [52] [] 'EDS: Laser simulation mode active. No laser emission' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3032 >
|
|
<A [28] [] 'EDS: Fuse 24V peripheral NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3506 >
|
|
<A [53] [] 'EDS: Aspiration settings too low. Beware of pollution' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3033 >
|
|
<A [23] [] 'EDS: Fuse 24V drive NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3038 >
|
|
<A [28] [] 'EDS: process stopped by user' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3039 >
|
|
<A [27] [] 'EDS: time out vacuum infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1086 >
|
|
<A [25] [] 'CV1: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3036 >
|
|
<A [30] [] 'EDS: time out gripper ref glas' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3037 >
|
|
<A [36] [] 'EDS: error air pressure out of range' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3026 >
|
|
<A [30] [] 'EDS: time out gripper linear 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3027 >
|
|
<A [34] [] 'EDS: Fuse 24V Operator buttons NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3024 >
|
|
<A [30] [] 'EDS: air conditioning CA fault' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1073 >
|
|
<A [21] [] 'CV1: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3025 >
|
|
<A [30] [] 'EDS: time out gripper linear 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3030 >
|
|
<A [30] [] 'EDS: time out gripper linear 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3031 >
|
|
<A [31] [] 'EDS: Fuse 24V miscellaneous NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3028 >
|
|
<A [24] [] 'EDS: Fuse supply Asi NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3029 >
|
|
<A [21] [] 'EDS: Fuse 24V IPC NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2065 >
|
|
<A [31] [] 'SBS: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2067 >
|
|
<A [29] [] 'SBS: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2066 >
|
|
<A [29] [] 'SBS: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2069 >
|
|
<A [40] [] 'SBS: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2068 >
|
|
<A [30] [] 'SBS: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2070 >
|
|
<A [20] [] 'SBS: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2073 >
|
|
<A [21] [] 'SBS: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2017 >
|
|
<A [19] [] 'SBS: Error lift low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2016 >
|
|
<A [27] [] 'SBS: Error single centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2019 >
|
|
<A [17] [] 'SBS: Error vacuum' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2018 >
|
|
<A [18] [] 'SBS: Error lift up' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2002 >
|
|
<A [23] [] 'SBS: Estop right active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2003 >
|
|
<A [38] [] 'SBS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2001 >
|
|
<A [22] [] 'SBS: Estop Left active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2006 >
|
|
<A [18] [] 'SBS: Error Brush 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2007 >
|
|
<A [18] [] 'SBS: Error Brush 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2004 >
|
|
<A [25] [] 'SBS: Error conveyor drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2005 >
|
|
<A [19] [] 'SBS: Error Brush 1 ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2010 >
|
|
<A [22] [] 'SBS: Estop line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2008 >
|
|
<A [18] [] 'SBS: Error Brush 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2009 >
|
|
<A [35] [] 'SBS: Error brush 1 linear movement ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2014 >
|
|
<A [34] [] 'SBS: Error brush 4 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2015 >
|
|
<A [25] [] 'SBS: Error dual centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2012 >
|
|
<A [34] [] 'SBS: Error brush 2 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2013 >
|
|
<A [34] [] 'SBS: Error brush 3 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2086 >
|
|
<A [25] [] 'SBS: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1010 >
|
|
<A [22] [] 'CV1: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1001 >
|
|
<A [22] [] 'CV1: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1003 >
|
|
<A [38] [] 'CV1: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1002 >
|
|
<A [23] [] 'CV1: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1005 >
|
|
<A [43] [] 'CV1: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1004 >
|
|
<A [25] [] 'CV1: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1006 >
|
|
<A [31] [] 'CV1: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3072 >
|
|
<A [32] [] 'EDS: Fuse Drives 400V supply NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3073 >
|
|
<A [38] [] 'EDS: SQ stopped by HMI => no PLC error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3074 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 1 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3075 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 2 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3076 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 3 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3077 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 4 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3078 >
|
|
<A [45] [] 'EDS: Aspiration flow ASP too low (upper head)' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3079 >
|
|
<A [45] [] 'EDS: Aspiration flow PHD too low (lower head)' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:29,872 [SEND] S7F19 W System Bytes=17
|
|
|
|
2023-01-10 11:08:29,887 [RECV] S7F20 System Bytes=17
|
|
<L [8]
|
|
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
|
|
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:30,418 [SEND] S2F13 W System Bytes=18
|
|
<L [14]
|
|
<U4 [1] [EnableAlarmReportSend] 4 >
|
|
<U4 [1] [TimeFormat] 8 >
|
|
<U4 [1] [MaxTerminalMsgLength] 9 >
|
|
<U4 [1] [EstablishCommunicationsTimeout] 49 >
|
|
<U4 [1] [DefaultCommunicationState] 12 >
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U4 [1] [DefaultOfflineSubState] 17 >
|
|
<U4 [1] [EnableSpooling] 40 >
|
|
<U4 [1] [OverWriteSpool] 42 >
|
|
<U4 [1] [MaxSpoolMessages] 43 >
|
|
<U4 [1] [MaxSpoolTransmit] 44 >
|
|
<U4 [1] [MDLN] 1 >
|
|
<U4 [1] [SOFTREV] 2 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:30,434 [RECV] S2F14 System Bytes=18
|
|
<L [14]
|
|
<BOOLEAN [1] [] T >
|
|
<U1 [1] [] 2 >
|
|
<U4 [1] [] 80 >
|
|
<I2 [1] [] 30 >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 2 >
|
|
<BOOLEAN [1] [] T >
|
|
<BOOLEAN [1] [] T >
|
|
<U4 [1] [] 100000 >
|
|
<U4 [1] [] 0 >
|
|
<L [0]
|
|
>
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:30,964 [SEND] S2F15 W System Bytes=19
|
|
<L [2]
|
|
<L [2]
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
<L [2]
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:30,979 [RECV] S2F16 System Bytes=19
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:31,508 [SEND] S1F15 W System Bytes=20
|
|
|
|
2023-01-10 11:08:31,523 [RECV] S1F16 System Bytes=20
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:31,528 [RECV] S6F11 W System Bytes=453
|
|
<L [3]
|
|
<U4 [1] [] 45 >
|
|
<U4 [1] [] 1 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 1 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:05:41.070Z' >
|
|
<U1 [1] [] 3 >
|
|
<U1 [1] [] 5 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:31,531 [SEND] S6F12 W System Bytes=453
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:32,049 [SEND] S1F17 W System Bytes=21
|
|
|
|
2023-01-10 11:08:32,064 [RECV] S6F11 W System Bytes=454
|
|
<L [3]
|
|
<U4 [1] [] 46 >
|
|
<U4 [1] [] 3 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 3 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:05:41.611Z' >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:32,064 [RECV] S1F18 System Bytes=21
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:32,073 [SEND] S6F12 W System Bytes=454
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:08:32,596 [SEND] S1F3 W System Bytes=22
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:32,616 [RECV] S1F4 System Bytes=22
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:05:42.158Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 4000 >
|
|
<I2 [1] [] 4000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:33,155 [SEND] S2F23 W System Bytes=23
|
|
<L [5]
|
|
<U4 [1] [TRID] 1 >
|
|
<A [6] [DSPER_hhmmss] '000010' >
|
|
<U4 [1] [TOTSMP] 0 >
|
|
<U4 [1] [REPGSZ] 1 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:08:33,169 [RECV] S2F24 System Bytes=23
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:10:14,803 [RECV] S6F11 W System Bytes=458
|
|
<L [3]
|
|
<U4 [1] [] 47 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:07:24.340Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:10:14,810 [SEND] S6F12 W System Bytes=458
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:10:21,472 [RECV] S6F11 W System Bytes=459
|
|
<L [3]
|
|
<U4 [1] [] 48 >
|
|
<U4 [1] [] 300041 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200041 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:07:31.016Z' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:10:21,478 [SEND] S6F12 W System Bytes=459
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:10:33,922 [RECV] S6F11 W System Bytes=461
|
|
<L [3]
|
|
<U4 [1] [] 49 >
|
|
<U4 [1] [] 300061 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200061 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:07:43.458Z' >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:10:33,937 [SEND] S6F12 W System Bytes=461
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:10:33,952 [RECV] S6F11 W System Bytes=462
|
|
<L [3]
|
|
<U4 [1] [] 50 >
|
|
<U4 [1] [] 300061 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200061 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:07:43.461Z' >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:10:33,967 [SEND] S6F12 W System Bytes=462
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:10:44,374 [RECV] S6F11 W System Bytes=463
|
|
<L [3]
|
|
<U4 [1] [] 51 >
|
|
<U4 [1] [] 300011 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200011 >
|
|
<L [5]
|
|
<A [24] [] '2023-01-10T03:07:53.916Z' >
|
|
<A [17] [] 'a2023010903310702' >
|
|
<A [4] [] 'LEDE' >
|
|
<A [0] [] '' >
|
|
<BOOLEAN [1] [] F >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:10:44,389 [SEND] S6F12 W System Bytes=463
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:11,338 [SEND] S1F13 W System Bytes=24
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:11,345 [RECV] S1F13 W System Bytes=466
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:11,352 [SEND] S1F14 System Bytes=466
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:11,607 [RECV] S1F14 System Bytes=24
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:12,136 [SEND] S1F17 W System Bytes=25
|
|
|
|
2023-01-10 11:11:12,151 [RECV] S1F18 System Bytes=25
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:11:12,680 [SEND] S1F3 W System Bytes=26
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:12,695 [RECV] S1F4 System Bytes=26
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:08:22.240Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:13,226 [SEND] S6F23 W System Bytes=27
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:11:13,241 [RECV] S6F24 System Bytes=27
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:13,302 [RECV] S6F11 W System Bytes=467
|
|
<L [3]
|
|
<U4 [1] [] 52 >
|
|
<U4 [1] [] 22 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 22 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:08:10.606Z' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<A [24] [] '2023-01-10T03:05:32.752Z' >
|
|
<A [24] [] '2023-01-10T03:05:32.752Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:13,316 [SEND] S6F12 W System Bytes=467
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:13,347 [RECV] S6F11 W System Bytes=468
|
|
<L [3]
|
|
<U4 [1] [] 53 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:08:22.883Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:05:32.752Z' >
|
|
<A [24] [] '2023-01-10T03:08:10.606Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:13,362 [SEND] S6F12 W System Bytes=468
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:13,369 [SEND] S2F43 W System Bytes=28
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:13,422 [RECV] S6F11 W System Bytes=469
|
|
<L [3]
|
|
<U4 [1] [] 54 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:08:22.969Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:05:32.752Z' >
|
|
<A [24] [] '2023-01-10T03:08:10.606Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:13,437 [SEND] S6F12 W System Bytes=469
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:13,452 [RECV] S2F44 System Bytes=28
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:13,978 [SEND] S2F37 W System Bytes=29
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:14,008 [RECV] S2F38 System Bytes=29
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:14,540 [SEND] S2F35 W System Bytes=30
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:14,555 [RECV] S2F36 System Bytes=30
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:15,087 [SEND] S2F33 W System Bytes=31
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:15,118 [RECV] S2F34 System Bytes=31
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:15,633 [SEND] S5F3 W System Bytes=32
|
|
<L [2]
|
|
<B [1] [ALED] '' 00 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:15,649 [RECV] S5F4 System Bytes=32
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:11:16,177 [SEND] S2F33 W System Bytes=33
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [reportid] 1 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 2 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 3 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 11 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 12 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 21 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 22 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 23 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200011 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200012 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200013 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200021 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200022 >
|
|
<L [16]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [ProcessResult] 1013 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [ProcessDurationSBS] 1015 >
|
|
<U4 [1] [ProcessDurationEDS] 1016 >
|
|
<U4 [1] [ProcessRecipeId] 1017 >
|
|
<U4 [1] [ProcessRecipeName] 1018 >
|
|
<U4 [1] [ProcessRecipeVersion] 1019 >
|
|
<U4 [1] [ProcessRecipeCreationDate] 1020 >
|
|
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
|
|
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
|
|
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
|
|
<U4 [1] [MeasuredSubstrateWidth] 1024 >
|
|
<U4 [1] [MeasuredSubstrateLength] 1025 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200032 >
|
|
<L [56]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID_CV1] 1046 >
|
|
<U4 [1] [SubstrateID_SBS] 1047 >
|
|
<U4 [1] [SubstrateID_EDS1] 1048 >
|
|
<U4 [1] [SubstrateID_EDS2] 1049 >
|
|
<U4 [1] [SubstrateID_CV2] 1050 >
|
|
<U4 [1] [LocationId_CV1] 1051 >
|
|
<U4 [1] [LocationId_SBS] 1052 >
|
|
<U4 [1] [LocationId_EDS1] 1053 >
|
|
<U4 [1] [LocationId_EDS2] 1054 >
|
|
<U4 [1] [LocationId_CV2] 1055 >
|
|
<U4 [1] [Slot1_CV1] 1056 >
|
|
<U4 [1] [Slot1_SBS] 1057 >
|
|
<U4 [1] [Slot1_EDS1] 1058 >
|
|
<U4 [1] [Slot1_EDS2] 1059 >
|
|
<U4 [1] [Slot1_CV2] 1060 >
|
|
<U4 [1] [Target_A_1] 1061 >
|
|
<U4 [1] [Target_A_2] 1062 >
|
|
<U4 [1] [Target_A_3] 1063 >
|
|
<U4 [1] [Target_A_4] 1064 >
|
|
<U4 [1] [Target_A_5] 1065 >
|
|
<U4 [1] [Target_B_1] 1066 >
|
|
<U4 [1] [Target_B_2] 1067 >
|
|
<U4 [1] [Target_B_3] 1068 >
|
|
<U4 [1] [Target_B_4] 1069 >
|
|
<U4 [1] [Target_B_5] 1070 >
|
|
<U4 [1] [Target_C_1] 1071 >
|
|
<U4 [1] [Target_C_2] 1072 >
|
|
<U4 [1] [Target_C_3] 1073 >
|
|
<U4 [1] [Target_C_4] 1074 >
|
|
<U4 [1] [Target_C_5] 1075 >
|
|
<U4 [1] [Target_D_1] 1076 >
|
|
<U4 [1] [Target_D_2] 1077 >
|
|
<U4 [1] [Target_D_3] 1078 >
|
|
<U4 [1] [Target_D_4] 1079 >
|
|
<U4 [1] [Target_D_5] 1080 >
|
|
<U4 [1] [Reroute_A_1] 1081 >
|
|
<U4 [1] [Reroute_A_2] 1082 >
|
|
<U4 [1] [Reroute_A_3] 1083 >
|
|
<U4 [1] [Reroute_A_4] 1084 >
|
|
<U4 [1] [Reroute_A_5] 1085 >
|
|
<U4 [1] [Reroute_B_1] 1086 >
|
|
<U4 [1] [Reroute_B_2] 1087 >
|
|
<U4 [1] [Reroute_B_3] 1088 >
|
|
<U4 [1] [Reroute_B_4] 1089 >
|
|
<U4 [1] [Reroute_B_5] 1090 >
|
|
<U4 [1] [Reroute_C_1] 1091 >
|
|
<U4 [1] [Reroute_C_2] 1092 >
|
|
<U4 [1] [Reroute_C_3] 1093 >
|
|
<U4 [1] [Reroute_C_4] 1094 >
|
|
<U4 [1] [Reroute_C_5] 1095 >
|
|
<U4 [1] [Reroute_D_1] 1096 >
|
|
<U4 [1] [Reroute_D_2] 1097 >
|
|
<U4 [1] [Reroute_D_3] 1098 >
|
|
<U4 [1] [Reroute_D_4] 1099 >
|
|
<U4 [1] [Reroute_D_5] 1100 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200041 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200042 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200052 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200055 >
|
|
<L [2]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [PPChangeName] 1011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200061 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:16,206 [RECV] S2F34 System Bytes=33
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:16,738 [SEND] S2F35 W System Bytes=34
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [CEID] 1 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 2 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 2 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 3 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 3 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 11 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 11 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 12 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 12 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 21 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 21 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 22 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 22 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 23 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 23 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300011 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300012 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200012 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300013 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300021 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200021 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300022 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200022 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300032 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200032 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300041 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200041 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300042 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200042 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300052 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200052 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300055 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200055 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300061 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200061 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:16,769 [RECV] S2F36 System Bytes=34
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:17,296 [SEND] S2F37 W System Bytes=35
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] T >
|
|
<L [19]
|
|
<U4 [1] [EquipmentOffline] 1 >
|
|
<U4 [1] [ControlStateLocal] 2 >
|
|
<U4 [1] [ControlStateRemote] 3 >
|
|
<U4 [1] [AlarmDetected] 11 >
|
|
<U4 [1] [AlarmCleared] 12 >
|
|
<U4 [1] [SpoolTransmitFailure] 21 >
|
|
<U4 [1] [SpoolingActivated] 22 >
|
|
<U4 [1] [SpoolingDeactivated] 23 >
|
|
<U4 [1] [Material_Received] 300011 >
|
|
<U4 [1] [Material_Removed] 300012 >
|
|
<U4 [1] [Material_Hold] 300013 >
|
|
<U4 [1] [Process_Start] 300021 >
|
|
<U4 [1] [Process_Finish] 300022 >
|
|
<U4 [1] [Slotlist] 300032 >
|
|
<U4 [1] [UserLoggedOn] 300041 >
|
|
<U4 [1] [UserLoggedOff] 300042 >
|
|
<U4 [1] [ProcessRecipeSelected] 300052 >
|
|
<U4 [1] [ProcessProgramChange] 300055 >
|
|
<U4 [1] [EquipmentStateChange] 300061 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:17,326 [RECV] S2F38 System Bytes=35
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:17,859 [SEND] S5F3 W System Bytes=36
|
|
<L [2]
|
|
<B [1] [ALED] '' 80 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:17,894 [RECV] S5F4 System Bytes=36
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:11:18,418 [SEND] S2F43 W System Bytes=37
|
|
<L [2]
|
|
<L [2]
|
|
<U1 [1] [STRID] 5 >
|
|
<L [1]
|
|
<U1 [1] [] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U1 [1] [STRID] 6 >
|
|
<L [1]
|
|
<U1 [1] [] 11 >
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:18,433 [RECV] S2F44 System Bytes=37
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:18,964 [SEND] S1F3 W System Bytes=38
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:18,980 [RECV] S1F4 System Bytes=38
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:08:28.524Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:19,511 [SEND] S5F5 W System Bytes=39
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:19,540 [RECV] S5F6 System Bytes=39
|
|
<L [135]
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4065 >
|
|
<A [31] [] 'CV2: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4067 >
|
|
<A [29] [] 'CV2: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4066 >
|
|
<A [29] [] 'CV2: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4069 >
|
|
<A [40] [] 'CV2: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4068 >
|
|
<A [30] [] 'CV2: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4070 >
|
|
<A [20] [] 'CV2: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4073 >
|
|
<A [21] [] 'CV2: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3004 >
|
|
<A [36] [] 'EDS: Estop left infeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3005 >
|
|
<A [38] [] 'EDS: Estop right infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3006 >
|
|
<A [39] [] 'EDS: Estop right outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3007 >
|
|
<A [40] [] 'EDS: Estop right infeed inside activexxx' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3001 >
|
|
<A [25] [] 'EDS: Estop cabinet active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3002 >
|
|
<A [37] [] 'EDS: Estop left infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4086 >
|
|
<A [25] [] 'CV2: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3003 >
|
|
<A [38] [] 'EDS: Estop left outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3049 >
|
|
<A [38] [] 'EDS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4005 >
|
|
<A [43] [] 'CV2: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3048 >
|
|
<A [40] [] 'EDS: Safety fault feedback Estop circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4004 >
|
|
<A [25] [] 'CV2: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3051 >
|
|
<A [22] [] 'EDS: Error door left 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3050 >
|
|
<A [40] [] 'EDS: Safety fault feedback laser circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4006 >
|
|
<A [31] [] 'CV2: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3053 >
|
|
<A [22] [] 'EDS: Error door left 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4001 >
|
|
<A [22] [] 'CV2: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3052 >
|
|
<A [22] [] 'EDS: Error door left 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3055 >
|
|
<A [23] [] 'EDS: Error door right 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4003 >
|
|
<A [38] [] 'CV2: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3054 >
|
|
<A [22] [] 'EDS: Error door left 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4002 >
|
|
<A [23] [] 'CV2: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3041 >
|
|
<A [18] [] 'EDS: Error chiller' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3040 >
|
|
<A [28] [] 'EDS: time out vacuum outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3043 >
|
|
<A [26] [] 'EDS: Error aspiration unit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3042 >
|
|
<A [23] [] 'EDS: Error Flap outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3045 >
|
|
<A [29] [] 'EDS: Error drive align infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3044 >
|
|
<A [22] [] 'EDS: Error flap infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3047 >
|
|
<A [32] [] 'EDS: Error drive conveyor infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3046 >
|
|
<A [30] [] 'EDS: Error drive align outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4010 >
|
|
<A [22] [] 'CV2: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3064 >
|
|
<A [60] [] 'EDS: laser commisiioning active // automatik mode prohibited' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3065 >
|
|
<A [42] [] 'EDS: Interface downstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3066 >
|
|
<A [40] [] 'EDS: Interface upstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3067 >
|
|
<A [31] [] 'EDS: Interface downstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3068 >
|
|
<A [29] [] 'EDS: Interface upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3069 >
|
|
<A [41] [] 'EDS: gap sensor not free / transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3070 >
|
|
<A [20] [] 'EDS: HMI-PLC Timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3071 >
|
|
<A [33] [] 'EDS: Aligning axis not referenced' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3056 >
|
|
<A [23] [] 'EDS: Error door right 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3057 >
|
|
<A [23] [] 'EDS: Error door right 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3058 >
|
|
<A [23] [] 'EDS: Error door right 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3062 >
|
|
<A [33] [] 'EDS: Error drive conveyor outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3063 >
|
|
<A [50] [] 'EDS: Gripper free with data / glass not in gripper' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3019 >
|
|
<A [23] [] 'EDS: time out gripper 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1066 >
|
|
<A [29] [] 'CV1: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3018 >
|
|
<A [23] [] 'EDS: time out gripper 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1067 >
|
|
<A [29] [] 'CV1: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3017 >
|
|
<A [31] [] 'EDS: time out gripper Aligning2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3016 >
|
|
<A [31] [] 'EDS: time out gripper Aligning1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1065 >
|
|
<A [31] [] 'CV1: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3023 >
|
|
<A [30] [] 'EDS: time out gripper linear 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1070 >
|
|
<A [20] [] 'CV1: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3022 >
|
|
<A [23] [] 'EDS: time out gripper 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3021 >
|
|
<A [23] [] 'EDS: time out gripper 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1068 >
|
|
<A [30] [] 'CV1: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3020 >
|
|
<A [21] [] 'EDS: Fuse chiller NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1069 >
|
|
<A [40] [] 'CV1: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3011 >
|
|
<A [16] [] 'EDS: Laser error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3010 >
|
|
<A [31] [] 'EDS: Estop extern active active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3009 >
|
|
<A [41] [] 'EDS: Estop right outfeed inside activeyyy' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3008 >
|
|
<A [37] [] 'EDS: Estop left outfeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3015 >
|
|
<A [29] [] 'EDS: Fuse cabinet cooling NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3501 >
|
|
<A [42] [] 'EDS: Automatic power measurement requested' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3014 >
|
|
<A [31] [] 'EDS: Overvoltage protection NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3013 >
|
|
<A [33] [] 'EDS: Communication with Laser NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3012 >
|
|
<A [34] [] 'EDS: Fuse Power supply Laser 1 NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3034 >
|
|
<A [37] [] 'EDS: time out conveyor lifting infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3035 >
|
|
<A [38] [] 'EDS: time out conveyor lifting outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3505 >
|
|
<A [52] [] 'EDS: Laser simulation mode active. No laser emission' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3032 >
|
|
<A [28] [] 'EDS: Fuse 24V peripheral NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3506 >
|
|
<A [53] [] 'EDS: Aspiration settings too low. Beware of pollution' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3033 >
|
|
<A [23] [] 'EDS: Fuse 24V drive NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3038 >
|
|
<A [28] [] 'EDS: process stopped by user' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3039 >
|
|
<A [27] [] 'EDS: time out vacuum infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1086 >
|
|
<A [25] [] 'CV1: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3036 >
|
|
<A [30] [] 'EDS: time out gripper ref glas' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3037 >
|
|
<A [36] [] 'EDS: error air pressure out of range' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3026 >
|
|
<A [30] [] 'EDS: time out gripper linear 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3027 >
|
|
<A [34] [] 'EDS: Fuse 24V Operator buttons NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3024 >
|
|
<A [30] [] 'EDS: air conditioning CA fault' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1073 >
|
|
<A [21] [] 'CV1: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3025 >
|
|
<A [30] [] 'EDS: time out gripper linear 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3030 >
|
|
<A [30] [] 'EDS: time out gripper linear 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3031 >
|
|
<A [31] [] 'EDS: Fuse 24V miscellaneous NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3028 >
|
|
<A [24] [] 'EDS: Fuse supply Asi NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3029 >
|
|
<A [21] [] 'EDS: Fuse 24V IPC NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2065 >
|
|
<A [31] [] 'SBS: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2067 >
|
|
<A [29] [] 'SBS: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2066 >
|
|
<A [29] [] 'SBS: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2069 >
|
|
<A [40] [] 'SBS: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2068 >
|
|
<A [30] [] 'SBS: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2070 >
|
|
<A [20] [] 'SBS: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2073 >
|
|
<A [21] [] 'SBS: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2017 >
|
|
<A [19] [] 'SBS: Error lift low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2016 >
|
|
<A [27] [] 'SBS: Error single centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2019 >
|
|
<A [17] [] 'SBS: Error vacuum' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2018 >
|
|
<A [18] [] 'SBS: Error lift up' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2002 >
|
|
<A [23] [] 'SBS: Estop right active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2003 >
|
|
<A [38] [] 'SBS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2001 >
|
|
<A [22] [] 'SBS: Estop Left active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2006 >
|
|
<A [18] [] 'SBS: Error Brush 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2007 >
|
|
<A [18] [] 'SBS: Error Brush 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2004 >
|
|
<A [25] [] 'SBS: Error conveyor drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2005 >
|
|
<A [19] [] 'SBS: Error Brush 1 ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2010 >
|
|
<A [22] [] 'SBS: Estop line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2008 >
|
|
<A [18] [] 'SBS: Error Brush 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2009 >
|
|
<A [35] [] 'SBS: Error brush 1 linear movement ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2014 >
|
|
<A [34] [] 'SBS: Error brush 4 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2015 >
|
|
<A [25] [] 'SBS: Error dual centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2012 >
|
|
<A [34] [] 'SBS: Error brush 2 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2013 >
|
|
<A [34] [] 'SBS: Error brush 3 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2086 >
|
|
<A [25] [] 'SBS: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1010 >
|
|
<A [22] [] 'CV1: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1001 >
|
|
<A [22] [] 'CV1: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1003 >
|
|
<A [38] [] 'CV1: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1002 >
|
|
<A [23] [] 'CV1: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1005 >
|
|
<A [43] [] 'CV1: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1004 >
|
|
<A [25] [] 'CV1: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1006 >
|
|
<A [31] [] 'CV1: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3072 >
|
|
<A [32] [] 'EDS: Fuse Drives 400V supply NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3073 >
|
|
<A [38] [] 'EDS: SQ stopped by HMI => no PLC error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3074 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 1 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3075 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 2 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3076 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 3 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3077 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 4 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3078 >
|
|
<A [45] [] 'EDS: Aspiration flow ASP too low (upper head)' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3079 >
|
|
<A [45] [] 'EDS: Aspiration flow PHD too low (lower head)' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:20,067 [SEND] S7F19 W System Bytes=40
|
|
|
|
2023-01-10 11:11:20,082 [RECV] S7F20 System Bytes=40
|
|
<L [8]
|
|
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
|
|
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:31,368 [SEND] S1F13 W System Bytes=42
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:31,383 [RECV] S1F13 W System Bytes=471
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:31,385 [SEND] S1F14 System Bytes=471
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:31,637 [RECV] S1F14 System Bytes=42
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:32,170 [SEND] S1F17 W System Bytes=43
|
|
|
|
2023-01-10 11:11:32,185 [RECV] S1F18 System Bytes=43
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:11:32,712 [SEND] S1F3 W System Bytes=44
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:32,727 [RECV] S1F4 System Bytes=44
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:08:42.273Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:33,258 [SEND] S6F23 W System Bytes=45
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:11:33,273 [RECV] S6F24 System Bytes=45
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:33,333 [RECV] S6F11 W System Bytes=472
|
|
<L [3]
|
|
<U4 [1] [] 55 >
|
|
<U4 [1] [] 22 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 22 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:08:29.911Z' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<A [24] [] '2023-01-10T03:08:22.967Z' >
|
|
<A [24] [] '2023-01-10T03:08:22.967Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:33,347 [SEND] S6F12 W System Bytes=472
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:33,363 [RECV] S6F11 W System Bytes=473
|
|
<L [3]
|
|
<U4 [1] [] 56 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:08:42.910Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:08:22.967Z' >
|
|
<A [24] [] '2023-01-10T03:08:29.909Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:33,378 [SEND] S6F12 W System Bytes=473
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:33,385 [SEND] S2F43 W System Bytes=46
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:33,453 [RECV] S6F11 W System Bytes=474
|
|
<L [3]
|
|
<U4 [1] [] 57 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:08:42.988Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:08:22.967Z' >
|
|
<A [24] [] '2023-01-10T03:08:29.909Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:33,468 [SEND] S6F12 W System Bytes=474
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:33,483 [RECV] S2F44 System Bytes=46
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:34,008 [SEND] S2F37 W System Bytes=47
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:34,037 [RECV] S2F38 System Bytes=47
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:34,571 [SEND] S2F35 W System Bytes=48
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:34,586 [RECV] S2F36 System Bytes=48
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:35,116 [SEND] S2F33 W System Bytes=49
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:35,131 [RECV] S2F34 System Bytes=49
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:35,661 [SEND] S5F3 W System Bytes=50
|
|
<L [2]
|
|
<B [1] [ALED] '' 00 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:35,676 [RECV] S5F4 System Bytes=50
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:11:36,207 [SEND] S2F33 W System Bytes=51
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [reportid] 1 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 2 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 3 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 11 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 12 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 21 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 22 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 23 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200011 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200012 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200013 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200021 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200022 >
|
|
<L [16]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [ProcessResult] 1013 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [ProcessDurationSBS] 1015 >
|
|
<U4 [1] [ProcessDurationEDS] 1016 >
|
|
<U4 [1] [ProcessRecipeId] 1017 >
|
|
<U4 [1] [ProcessRecipeName] 1018 >
|
|
<U4 [1] [ProcessRecipeVersion] 1019 >
|
|
<U4 [1] [ProcessRecipeCreationDate] 1020 >
|
|
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
|
|
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
|
|
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
|
|
<U4 [1] [MeasuredSubstrateWidth] 1024 >
|
|
<U4 [1] [MeasuredSubstrateLength] 1025 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200032 >
|
|
<L [56]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID_CV1] 1046 >
|
|
<U4 [1] [SubstrateID_SBS] 1047 >
|
|
<U4 [1] [SubstrateID_EDS1] 1048 >
|
|
<U4 [1] [SubstrateID_EDS2] 1049 >
|
|
<U4 [1] [SubstrateID_CV2] 1050 >
|
|
<U4 [1] [LocationId_CV1] 1051 >
|
|
<U4 [1] [LocationId_SBS] 1052 >
|
|
<U4 [1] [LocationId_EDS1] 1053 >
|
|
<U4 [1] [LocationId_EDS2] 1054 >
|
|
<U4 [1] [LocationId_CV2] 1055 >
|
|
<U4 [1] [Slot1_CV1] 1056 >
|
|
<U4 [1] [Slot1_SBS] 1057 >
|
|
<U4 [1] [Slot1_EDS1] 1058 >
|
|
<U4 [1] [Slot1_EDS2] 1059 >
|
|
<U4 [1] [Slot1_CV2] 1060 >
|
|
<U4 [1] [Target_A_1] 1061 >
|
|
<U4 [1] [Target_A_2] 1062 >
|
|
<U4 [1] [Target_A_3] 1063 >
|
|
<U4 [1] [Target_A_4] 1064 >
|
|
<U4 [1] [Target_A_5] 1065 >
|
|
<U4 [1] [Target_B_1] 1066 >
|
|
<U4 [1] [Target_B_2] 1067 >
|
|
<U4 [1] [Target_B_3] 1068 >
|
|
<U4 [1] [Target_B_4] 1069 >
|
|
<U4 [1] [Target_B_5] 1070 >
|
|
<U4 [1] [Target_C_1] 1071 >
|
|
<U4 [1] [Target_C_2] 1072 >
|
|
<U4 [1] [Target_C_3] 1073 >
|
|
<U4 [1] [Target_C_4] 1074 >
|
|
<U4 [1] [Target_C_5] 1075 >
|
|
<U4 [1] [Target_D_1] 1076 >
|
|
<U4 [1] [Target_D_2] 1077 >
|
|
<U4 [1] [Target_D_3] 1078 >
|
|
<U4 [1] [Target_D_4] 1079 >
|
|
<U4 [1] [Target_D_5] 1080 >
|
|
<U4 [1] [Reroute_A_1] 1081 >
|
|
<U4 [1] [Reroute_A_2] 1082 >
|
|
<U4 [1] [Reroute_A_3] 1083 >
|
|
<U4 [1] [Reroute_A_4] 1084 >
|
|
<U4 [1] [Reroute_A_5] 1085 >
|
|
<U4 [1] [Reroute_B_1] 1086 >
|
|
<U4 [1] [Reroute_B_2] 1087 >
|
|
<U4 [1] [Reroute_B_3] 1088 >
|
|
<U4 [1] [Reroute_B_4] 1089 >
|
|
<U4 [1] [Reroute_B_5] 1090 >
|
|
<U4 [1] [Reroute_C_1] 1091 >
|
|
<U4 [1] [Reroute_C_2] 1092 >
|
|
<U4 [1] [Reroute_C_3] 1093 >
|
|
<U4 [1] [Reroute_C_4] 1094 >
|
|
<U4 [1] [Reroute_C_5] 1095 >
|
|
<U4 [1] [Reroute_D_1] 1096 >
|
|
<U4 [1] [Reroute_D_2] 1097 >
|
|
<U4 [1] [Reroute_D_3] 1098 >
|
|
<U4 [1] [Reroute_D_4] 1099 >
|
|
<U4 [1] [Reroute_D_5] 1100 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200041 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200042 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200052 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200055 >
|
|
<L [2]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [PPChangeName] 1011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200061 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:36,237 [RECV] S2F34 System Bytes=51
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:36,768 [SEND] S2F35 W System Bytes=52
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [CEID] 1 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 2 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 2 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 3 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 3 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 11 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 11 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 12 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 12 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 21 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 21 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 22 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 22 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 23 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 23 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300011 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300012 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200012 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300013 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300021 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200021 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300022 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200022 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300032 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200032 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300041 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200041 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300042 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200042 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300052 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200052 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300055 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200055 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300061 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200061 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:36,799 [RECV] S2F36 System Bytes=52
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:11:42,996 [SEND] S1F13 W System Bytes=54
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:43,003 [RECV] S1F13 W System Bytes=476
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:43,011 [SEND] S1F14 System Bytes=476
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:43,266 [RECV] S1F14 System Bytes=54
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:52,950 [SEND] S1F13 W System Bytes=56
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:52,957 [RECV] S1F13 W System Bytes=478
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:52,963 [SEND] S1F14 System Bytes=478
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:53,224 [RECV] S1F14 System Bytes=56
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:53,753 [SEND] S1F17 W System Bytes=57
|
|
|
|
2023-01-10 11:11:53,767 [RECV] S1F18 System Bytes=57
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:11:54,300 [SEND] S1F3 W System Bytes=58
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:54,315 [RECV] S1F4 System Bytes=58
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:09:03.861Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:54,843 [SEND] S6F23 W System Bytes=59
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:11:54,858 [RECV] S6F24 System Bytes=59
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:11:55,371 [SEND] S2F43 W System Bytes=60
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:55,401 [RECV] S2F44 System Bytes=60
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:55,931 [SEND] S2F37 W System Bytes=61
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:11:55,961 [RECV] S2F38 System Bytes=61
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:02,987 [SEND] S1F13 W System Bytes=63
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:03,005 [RECV] S1F13 W System Bytes=480
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:03,012 [SEND] S1F14 System Bytes=480
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:03,262 [RECV] S1F14 System Bytes=63
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:03,791 [SEND] S1F17 W System Bytes=64
|
|
|
|
2023-01-10 11:12:03,807 [RECV] S1F18 System Bytes=64
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:12:04,337 [SEND] S1F3 W System Bytes=65
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:04,352 [RECV] S1F4 System Bytes=65
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:09:13.898Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:04,881 [SEND] S6F23 W System Bytes=66
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:12:04,896 [RECV] S6F24 System Bytes=66
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:12:05,426 [SEND] S2F43 W System Bytes=67
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:05,457 [RECV] S2F44 System Bytes=67
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:05,747 T3 Timeout: System Bytes=41
|
|
2023-01-10 11:12:05,989 [SEND] S2F37 W System Bytes=68
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:06,021 [RECV] S2F38 System Bytes=68
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:06,551 [SEND] S2F35 W System Bytes=69
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:06,566 [RECV] S2F36 System Bytes=69
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:07,096 [SEND] S2F33 W System Bytes=70
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:07,111 [RECV] S2F34 System Bytes=70
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:07,641 [SEND] S5F3 W System Bytes=71
|
|
<L [2]
|
|
<B [1] [ALED] '' 00 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:07,656 [RECV] S5F4 System Bytes=71
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:12:08,186 [SEND] S2F33 W System Bytes=72
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [reportid] 1 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 2 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 3 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 11 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 12 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 21 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 22 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 23 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200011 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200012 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200013 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200021 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200022 >
|
|
<L [16]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [ProcessResult] 1013 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [ProcessDurationSBS] 1015 >
|
|
<U4 [1] [ProcessDurationEDS] 1016 >
|
|
<U4 [1] [ProcessRecipeId] 1017 >
|
|
<U4 [1] [ProcessRecipeName] 1018 >
|
|
<U4 [1] [ProcessRecipeVersion] 1019 >
|
|
<U4 [1] [ProcessRecipeCreationDate] 1020 >
|
|
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
|
|
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
|
|
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
|
|
<U4 [1] [MeasuredSubstrateWidth] 1024 >
|
|
<U4 [1] [MeasuredSubstrateLength] 1025 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200032 >
|
|
<L [56]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID_CV1] 1046 >
|
|
<U4 [1] [SubstrateID_SBS] 1047 >
|
|
<U4 [1] [SubstrateID_EDS1] 1048 >
|
|
<U4 [1] [SubstrateID_EDS2] 1049 >
|
|
<U4 [1] [SubstrateID_CV2] 1050 >
|
|
<U4 [1] [LocationId_CV1] 1051 >
|
|
<U4 [1] [LocationId_SBS] 1052 >
|
|
<U4 [1] [LocationId_EDS1] 1053 >
|
|
<U4 [1] [LocationId_EDS2] 1054 >
|
|
<U4 [1] [LocationId_CV2] 1055 >
|
|
<U4 [1] [Slot1_CV1] 1056 >
|
|
<U4 [1] [Slot1_SBS] 1057 >
|
|
<U4 [1] [Slot1_EDS1] 1058 >
|
|
<U4 [1] [Slot1_EDS2] 1059 >
|
|
<U4 [1] [Slot1_CV2] 1060 >
|
|
<U4 [1] [Target_A_1] 1061 >
|
|
<U4 [1] [Target_A_2] 1062 >
|
|
<U4 [1] [Target_A_3] 1063 >
|
|
<U4 [1] [Target_A_4] 1064 >
|
|
<U4 [1] [Target_A_5] 1065 >
|
|
<U4 [1] [Target_B_1] 1066 >
|
|
<U4 [1] [Target_B_2] 1067 >
|
|
<U4 [1] [Target_B_3] 1068 >
|
|
<U4 [1] [Target_B_4] 1069 >
|
|
<U4 [1] [Target_B_5] 1070 >
|
|
<U4 [1] [Target_C_1] 1071 >
|
|
<U4 [1] [Target_C_2] 1072 >
|
|
<U4 [1] [Target_C_3] 1073 >
|
|
<U4 [1] [Target_C_4] 1074 >
|
|
<U4 [1] [Target_C_5] 1075 >
|
|
<U4 [1] [Target_D_1] 1076 >
|
|
<U4 [1] [Target_D_2] 1077 >
|
|
<U4 [1] [Target_D_3] 1078 >
|
|
<U4 [1] [Target_D_4] 1079 >
|
|
<U4 [1] [Target_D_5] 1080 >
|
|
<U4 [1] [Reroute_A_1] 1081 >
|
|
<U4 [1] [Reroute_A_2] 1082 >
|
|
<U4 [1] [Reroute_A_3] 1083 >
|
|
<U4 [1] [Reroute_A_4] 1084 >
|
|
<U4 [1] [Reroute_A_5] 1085 >
|
|
<U4 [1] [Reroute_B_1] 1086 >
|
|
<U4 [1] [Reroute_B_2] 1087 >
|
|
<U4 [1] [Reroute_B_3] 1088 >
|
|
<U4 [1] [Reroute_B_4] 1089 >
|
|
<U4 [1] [Reroute_B_5] 1090 >
|
|
<U4 [1] [Reroute_C_1] 1091 >
|
|
<U4 [1] [Reroute_C_2] 1092 >
|
|
<U4 [1] [Reroute_C_3] 1093 >
|
|
<U4 [1] [Reroute_C_4] 1094 >
|
|
<U4 [1] [Reroute_C_5] 1095 >
|
|
<U4 [1] [Reroute_D_1] 1096 >
|
|
<U4 [1] [Reroute_D_2] 1097 >
|
|
<U4 [1] [Reroute_D_3] 1098 >
|
|
<U4 [1] [Reroute_D_4] 1099 >
|
|
<U4 [1] [Reroute_D_5] 1100 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200041 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200042 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200052 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200055 >
|
|
<L [2]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [PPChangeName] 1011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200061 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:08,200 [RECV] S2F34 System Bytes=72
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:08,727 [SEND] S2F35 W System Bytes=73
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [CEID] 1 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 2 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 2 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 3 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 3 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 11 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 11 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 12 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 12 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 21 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 21 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 22 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 22 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 23 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 23 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300011 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300012 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200012 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300013 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300021 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200021 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300022 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200022 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300032 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200032 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300041 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200041 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300042 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200042 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300052 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200052 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300055 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200055 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300061 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200061 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:08,757 [RECV] S2F36 System Bytes=73
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:09,286 [SEND] S2F37 W System Bytes=74
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] T >
|
|
<L [19]
|
|
<U4 [1] [EquipmentOffline] 1 >
|
|
<U4 [1] [ControlStateLocal] 2 >
|
|
<U4 [1] [ControlStateRemote] 3 >
|
|
<U4 [1] [AlarmDetected] 11 >
|
|
<U4 [1] [AlarmCleared] 12 >
|
|
<U4 [1] [SpoolTransmitFailure] 21 >
|
|
<U4 [1] [SpoolingActivated] 22 >
|
|
<U4 [1] [SpoolingDeactivated] 23 >
|
|
<U4 [1] [Material_Received] 300011 >
|
|
<U4 [1] [Material_Removed] 300012 >
|
|
<U4 [1] [Material_Hold] 300013 >
|
|
<U4 [1] [Process_Start] 300021 >
|
|
<U4 [1] [Process_Finish] 300022 >
|
|
<U4 [1] [Slotlist] 300032 >
|
|
<U4 [1] [UserLoggedOn] 300041 >
|
|
<U4 [1] [UserLoggedOff] 300042 >
|
|
<U4 [1] [ProcessRecipeSelected] 300052 >
|
|
<U4 [1] [ProcessProgramChange] 300055 >
|
|
<U4 [1] [EquipmentStateChange] 300061 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:09,314 [RECV] S2F38 System Bytes=74
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:09,853 [SEND] S5F3 W System Bytes=75
|
|
<L [2]
|
|
<B [1] [ALED] '' 80 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:09,868 [RECV] S5F4 System Bytes=75
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:12:10,391 [SEND] S2F43 W System Bytes=76
|
|
<L [2]
|
|
<L [2]
|
|
<U1 [1] [STRID] 5 >
|
|
<L [1]
|
|
<U1 [1] [] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U1 [1] [STRID] 6 >
|
|
<L [1]
|
|
<U1 [1] [] 11 >
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:10,406 [RECV] S2F44 System Bytes=76
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:10,930 [SEND] S1F3 W System Bytes=77
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:10,945 [RECV] S1F4 System Bytes=77
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:09:20.491Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:11,468 [SEND] S5F5 W System Bytes=78
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:11,503 [RECV] S5F6 System Bytes=78
|
|
<L [135]
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4065 >
|
|
<A [31] [] 'CV2: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4067 >
|
|
<A [29] [] 'CV2: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4066 >
|
|
<A [29] [] 'CV2: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4069 >
|
|
<A [40] [] 'CV2: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4068 >
|
|
<A [30] [] 'CV2: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4070 >
|
|
<A [20] [] 'CV2: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4073 >
|
|
<A [21] [] 'CV2: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3004 >
|
|
<A [36] [] 'EDS: Estop left infeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3005 >
|
|
<A [38] [] 'EDS: Estop right infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3006 >
|
|
<A [39] [] 'EDS: Estop right outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3007 >
|
|
<A [40] [] 'EDS: Estop right infeed inside activexxx' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3001 >
|
|
<A [25] [] 'EDS: Estop cabinet active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3002 >
|
|
<A [37] [] 'EDS: Estop left infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4086 >
|
|
<A [25] [] 'CV2: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3003 >
|
|
<A [38] [] 'EDS: Estop left outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3049 >
|
|
<A [38] [] 'EDS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4005 >
|
|
<A [43] [] 'CV2: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3048 >
|
|
<A [40] [] 'EDS: Safety fault feedback Estop circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4004 >
|
|
<A [25] [] 'CV2: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3051 >
|
|
<A [22] [] 'EDS: Error door left 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3050 >
|
|
<A [40] [] 'EDS: Safety fault feedback laser circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4006 >
|
|
<A [31] [] 'CV2: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3053 >
|
|
<A [22] [] 'EDS: Error door left 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4001 >
|
|
<A [22] [] 'CV2: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3052 >
|
|
<A [22] [] 'EDS: Error door left 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3055 >
|
|
<A [23] [] 'EDS: Error door right 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4003 >
|
|
<A [38] [] 'CV2: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3054 >
|
|
<A [22] [] 'EDS: Error door left 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4002 >
|
|
<A [23] [] 'CV2: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3041 >
|
|
<A [18] [] 'EDS: Error chiller' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3040 >
|
|
<A [28] [] 'EDS: time out vacuum outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3043 >
|
|
<A [26] [] 'EDS: Error aspiration unit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3042 >
|
|
<A [23] [] 'EDS: Error Flap outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3045 >
|
|
<A [29] [] 'EDS: Error drive align infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3044 >
|
|
<A [22] [] 'EDS: Error flap infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3047 >
|
|
<A [32] [] 'EDS: Error drive conveyor infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3046 >
|
|
<A [30] [] 'EDS: Error drive align outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4010 >
|
|
<A [22] [] 'CV2: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3064 >
|
|
<A [60] [] 'EDS: laser commisiioning active // automatik mode prohibited' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3065 >
|
|
<A [42] [] 'EDS: Interface downstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3066 >
|
|
<A [40] [] 'EDS: Interface upstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3067 >
|
|
<A [31] [] 'EDS: Interface downstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3068 >
|
|
<A [29] [] 'EDS: Interface upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3069 >
|
|
<A [41] [] 'EDS: gap sensor not free / transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3070 >
|
|
<A [20] [] 'EDS: HMI-PLC Timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3071 >
|
|
<A [33] [] 'EDS: Aligning axis not referenced' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3056 >
|
|
<A [23] [] 'EDS: Error door right 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3057 >
|
|
<A [23] [] 'EDS: Error door right 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3058 >
|
|
<A [23] [] 'EDS: Error door right 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3062 >
|
|
<A [33] [] 'EDS: Error drive conveyor outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3063 >
|
|
<A [50] [] 'EDS: Gripper free with data / glass not in gripper' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3019 >
|
|
<A [23] [] 'EDS: time out gripper 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1066 >
|
|
<A [29] [] 'CV1: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3018 >
|
|
<A [23] [] 'EDS: time out gripper 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1067 >
|
|
<A [29] [] 'CV1: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3017 >
|
|
<A [31] [] 'EDS: time out gripper Aligning2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3016 >
|
|
<A [31] [] 'EDS: time out gripper Aligning1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1065 >
|
|
<A [31] [] 'CV1: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3023 >
|
|
<A [30] [] 'EDS: time out gripper linear 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1070 >
|
|
<A [20] [] 'CV1: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3022 >
|
|
<A [23] [] 'EDS: time out gripper 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3021 >
|
|
<A [23] [] 'EDS: time out gripper 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1068 >
|
|
<A [30] [] 'CV1: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3020 >
|
|
<A [21] [] 'EDS: Fuse chiller NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1069 >
|
|
<A [40] [] 'CV1: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3011 >
|
|
<A [16] [] 'EDS: Laser error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3010 >
|
|
<A [31] [] 'EDS: Estop extern active active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3009 >
|
|
<A [41] [] 'EDS: Estop right outfeed inside activeyyy' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3008 >
|
|
<A [37] [] 'EDS: Estop left outfeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3015 >
|
|
<A [29] [] 'EDS: Fuse cabinet cooling NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3501 >
|
|
<A [42] [] 'EDS: Automatic power measurement requested' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3014 >
|
|
<A [31] [] 'EDS: Overvoltage protection NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3013 >
|
|
<A [33] [] 'EDS: Communication with Laser NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3012 >
|
|
<A [34] [] 'EDS: Fuse Power supply Laser 1 NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3034 >
|
|
<A [37] [] 'EDS: time out conveyor lifting infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3035 >
|
|
<A [38] [] 'EDS: time out conveyor lifting outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3505 >
|
|
<A [52] [] 'EDS: Laser simulation mode active. No laser emission' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3032 >
|
|
<A [28] [] 'EDS: Fuse 24V peripheral NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3506 >
|
|
<A [53] [] 'EDS: Aspiration settings too low. Beware of pollution' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3033 >
|
|
<A [23] [] 'EDS: Fuse 24V drive NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3038 >
|
|
<A [28] [] 'EDS: process stopped by user' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3039 >
|
|
<A [27] [] 'EDS: time out vacuum infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1086 >
|
|
<A [25] [] 'CV1: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3036 >
|
|
<A [30] [] 'EDS: time out gripper ref glas' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3037 >
|
|
<A [36] [] 'EDS: error air pressure out of range' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3026 >
|
|
<A [30] [] 'EDS: time out gripper linear 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3027 >
|
|
<A [34] [] 'EDS: Fuse 24V Operator buttons NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3024 >
|
|
<A [30] [] 'EDS: air conditioning CA fault' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1073 >
|
|
<A [21] [] 'CV1: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3025 >
|
|
<A [30] [] 'EDS: time out gripper linear 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3030 >
|
|
<A [30] [] 'EDS: time out gripper linear 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3031 >
|
|
<A [31] [] 'EDS: Fuse 24V miscellaneous NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3028 >
|
|
<A [24] [] 'EDS: Fuse supply Asi NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3029 >
|
|
<A [21] [] 'EDS: Fuse 24V IPC NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2065 >
|
|
<A [31] [] 'SBS: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2067 >
|
|
<A [29] [] 'SBS: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2066 >
|
|
<A [29] [] 'SBS: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2069 >
|
|
<A [40] [] 'SBS: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2068 >
|
|
<A [30] [] 'SBS: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2070 >
|
|
<A [20] [] 'SBS: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2073 >
|
|
<A [21] [] 'SBS: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2017 >
|
|
<A [19] [] 'SBS: Error lift low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2016 >
|
|
<A [27] [] 'SBS: Error single centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2019 >
|
|
<A [17] [] 'SBS: Error vacuum' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2018 >
|
|
<A [18] [] 'SBS: Error lift up' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2002 >
|
|
<A [23] [] 'SBS: Estop right active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2003 >
|
|
<A [38] [] 'SBS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2001 >
|
|
<A [22] [] 'SBS: Estop Left active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2006 >
|
|
<A [18] [] 'SBS: Error Brush 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2007 >
|
|
<A [18] [] 'SBS: Error Brush 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2004 >
|
|
<A [25] [] 'SBS: Error conveyor drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2005 >
|
|
<A [19] [] 'SBS: Error Brush 1 ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2010 >
|
|
<A [22] [] 'SBS: Estop line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2008 >
|
|
<A [18] [] 'SBS: Error Brush 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2009 >
|
|
<A [35] [] 'SBS: Error brush 1 linear movement ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2014 >
|
|
<A [34] [] 'SBS: Error brush 4 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2015 >
|
|
<A [25] [] 'SBS: Error dual centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2012 >
|
|
<A [34] [] 'SBS: Error brush 2 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2013 >
|
|
<A [34] [] 'SBS: Error brush 3 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2086 >
|
|
<A [25] [] 'SBS: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1010 >
|
|
<A [22] [] 'CV1: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1001 >
|
|
<A [22] [] 'CV1: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1003 >
|
|
<A [38] [] 'CV1: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1002 >
|
|
<A [23] [] 'CV1: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1005 >
|
|
<A [43] [] 'CV1: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1004 >
|
|
<A [25] [] 'CV1: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1006 >
|
|
<A [31] [] 'CV1: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3072 >
|
|
<A [32] [] 'EDS: Fuse Drives 400V supply NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3073 >
|
|
<A [38] [] 'EDS: SQ stopped by HMI => no PLC error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3074 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 1 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3075 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 2 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3076 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 3 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3077 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 4 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3078 >
|
|
<A [45] [] 'EDS: Aspiration flow ASP too low (upper head)' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3079 >
|
|
<A [45] [] 'EDS: Aspiration flow PHD too low (lower head)' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:12,039 [SEND] S7F19 W System Bytes=79
|
|
|
|
2023-01-10 11:12:12,069 [RECV] S7F20 System Bytes=79
|
|
<L [8]
|
|
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
|
|
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:12,599 [SEND] S2F13 W System Bytes=80
|
|
<L [14]
|
|
<U4 [1] [EnableAlarmReportSend] 4 >
|
|
<U4 [1] [TimeFormat] 8 >
|
|
<U4 [1] [MaxTerminalMsgLength] 9 >
|
|
<U4 [1] [EstablishCommunicationsTimeout] 49 >
|
|
<U4 [1] [DefaultCommunicationState] 12 >
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U4 [1] [DefaultOfflineSubState] 17 >
|
|
<U4 [1] [EnableSpooling] 40 >
|
|
<U4 [1] [OverWriteSpool] 42 >
|
|
<U4 [1] [MaxSpoolMessages] 43 >
|
|
<U4 [1] [MaxSpoolTransmit] 44 >
|
|
<U4 [1] [MDLN] 1 >
|
|
<U4 [1] [SOFTREV] 2 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:12,614 [RECV] S2F14 System Bytes=80
|
|
<L [14]
|
|
<BOOLEAN [1] [] T >
|
|
<U1 [1] [] 2 >
|
|
<U4 [1] [] 80 >
|
|
<I2 [1] [] 30 >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 2 >
|
|
<BOOLEAN [1] [] T >
|
|
<BOOLEAN [1] [] T >
|
|
<U4 [1] [] 100000 >
|
|
<U4 [1] [] 0 >
|
|
<L [0]
|
|
>
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:13,142 [SEND] S2F15 W System Bytes=81
|
|
<L [2]
|
|
<L [2]
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
<L [2]
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:13,157 [RECV] S2F16 System Bytes=81
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:13,674 [SEND] S1F15 W System Bytes=82
|
|
|
|
2023-01-10 11:12:13,689 [RECV] S1F16 System Bytes=82
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:13,696 [RECV] S6F11 W System Bytes=481
|
|
<L [3]
|
|
<U4 [1] [] 58 >
|
|
<U4 [1] [] 1 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 1 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:09:23.236Z' >
|
|
<U1 [1] [] 3 >
|
|
<U1 [1] [] 5 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:13,697 [SEND] S6F12 W System Bytes=481
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:14,216 [SEND] S1F17 W System Bytes=83
|
|
|
|
2023-01-10 11:12:14,231 [RECV] S6F11 W System Bytes=482
|
|
<L [3]
|
|
<U4 [1] [] 59 >
|
|
<U4 [1] [] 3 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 3 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:09:23.777Z' >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:14,231 [RECV] S1F18 System Bytes=83
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:14,237 [SEND] S6F12 W System Bytes=482
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:14,761 [SEND] S1F3 W System Bytes=84
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:14,776 [RECV] S1F4 System Bytes=84
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:09:24.319Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:15,299 [SEND] S2F23 W System Bytes=85
|
|
<L [5]
|
|
<U4 [1] [TRID] 1 >
|
|
<A [6] [DSPER_hhmmss] '000010' >
|
|
<U4 [1] [TOTSMP] 0 >
|
|
<U4 [1] [REPGSZ] 1 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:15,314 [RECV] S2F24 System Bytes=85
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:22,204 [RECV] S6F11 W System Bytes=483
|
|
<L [3]
|
|
<U4 [1] [] 60 >
|
|
<U4 [1] [] 300022 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200022 >
|
|
<L [16]
|
|
<A [24] [] '2023-01-10T03:09:31.747Z' >
|
|
<A [17] [] 'a2023010903310702' >
|
|
<BOOLEAN [1] [] F >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<U1 [1] [] 15 >
|
|
<U1 [1] [] 30 >
|
|
<I2 [1] [] 9 >
|
|
<A [22] [] 'CTF IAT Recipe_Jiamusi' >
|
|
<A [1] [] '7' >
|
|
<A [27] [] '2023-04-01T16:10:13.0000000' >
|
|
<A [27] [] '2023-09-01T20:51:53.0000000' >
|
|
<A [4] [] '4Jet' >
|
|
<A [4] [] '4Jet' >
|
|
<F4 [1] [] 1200.427 >
|
|
<F4 [1] [] 1600 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:22,205 [SEND] S6F12 W System Bytes=483
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:22,917 T3 Timeout: System Bytes=53
|
|
2023-01-10 11:12:28,968 T3 Timeout: System Bytes=55
|
|
2023-01-10 11:12:42,107 T3 Timeout: System Bytes=62
|
|
2023-01-10 11:12:45,100 [SEND] S1F13 W System Bytes=86
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:45,107 [RECV] S1F13 W System Bytes=486
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:45,115 [SEND] S1F14 System Bytes=486
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:45,360 [RECV] S1F14 System Bytes=86
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:45,887 [SEND] S1F17 W System Bytes=87
|
|
|
|
2023-01-10 11:12:45,903 [RECV] S1F18 System Bytes=87
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:12:46,433 [SEND] S1F3 W System Bytes=88
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:46,449 [RECV] S1F4 System Bytes=88
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:09:55.993Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 2 >
|
|
<U4 [1] [] 2 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:46,983 [SEND] S6F23 W System Bytes=89
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:12:46,998 [RECV] S6F24 System Bytes=89
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:47,059 [RECV] S6F11 W System Bytes=487
|
|
<L [3]
|
|
<U4 [1] [] 61 >
|
|
<U4 [1] [] 22 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 22 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:09:43.712Z' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<A [24] [] '2023-01-10T03:09:14.988Z' >
|
|
<A [24] [] '2023-01-10T03:09:14.988Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:47,074 [SEND] S6F12 W System Bytes=487
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:47,089 [RECV] S6F11 W System Bytes=488
|
|
<L [3]
|
|
<U4 [1] [] 62 >
|
|
<U4 [1] [] 300012 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 200012 >
|
|
<L [12]
|
|
<A [24] [] '2023-01-10T03:09:48.389Z' >
|
|
<A [17] [] 'a2023010903310702' >
|
|
<A [4] [] 'LEDE' >
|
|
<BOOLEAN [1] [] F >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:47,095 [SEND] S6F12 W System Bytes=488
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:47,119 [RECV] S6F11 W System Bytes=489
|
|
<L [3]
|
|
<U4 [1] [] 63 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:09:56.658Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 2 >
|
|
<U4 [1] [] 2 >
|
|
<A [24] [] '2023-01-10T03:09:14.988Z' >
|
|
<A [24] [] '2023-01-10T03:09:43.710Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:47,134 [SEND] S6F12 W System Bytes=489
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:47,141 [SEND] S2F43 W System Bytes=90
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:47,194 [RECV] S6F11 W System Bytes=490
|
|
<L [3]
|
|
<U4 [1] [] 64 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:09:56.741Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 2 >
|
|
<U4 [1] [] 2 >
|
|
<A [24] [] '2023-01-10T03:09:14.988Z' >
|
|
<A [24] [] '2023-01-10T03:09:43.710Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:47,209 [SEND] S6F12 W System Bytes=490
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:47,224 [RECV] S2F44 System Bytes=90
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:47,753 [SEND] S2F37 W System Bytes=91
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:47,768 [RECV] S2F38 System Bytes=91
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:48,295 [SEND] S2F35 W System Bytes=92
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:48,310 [RECV] S2F36 System Bytes=92
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:48,844 [SEND] S2F33 W System Bytes=93
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:48,860 [RECV] S2F34 System Bytes=93
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:49,390 [SEND] S5F3 W System Bytes=94
|
|
<L [2]
|
|
<B [1] [ALED] '' 00 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:49,420 [RECV] S5F4 System Bytes=94
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:12:49,953 [SEND] S2F33 W System Bytes=95
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [reportid] 1 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 2 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 3 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 11 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 12 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 21 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 22 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 23 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200011 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200012 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200013 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200021 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200022 >
|
|
<L [16]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [ProcessResult] 1013 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [ProcessDurationSBS] 1015 >
|
|
<U4 [1] [ProcessDurationEDS] 1016 >
|
|
<U4 [1] [ProcessRecipeId] 1017 >
|
|
<U4 [1] [ProcessRecipeName] 1018 >
|
|
<U4 [1] [ProcessRecipeVersion] 1019 >
|
|
<U4 [1] [ProcessRecipeCreationDate] 1020 >
|
|
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
|
|
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
|
|
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
|
|
<U4 [1] [MeasuredSubstrateWidth] 1024 >
|
|
<U4 [1] [MeasuredSubstrateLength] 1025 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200032 >
|
|
<L [56]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID_CV1] 1046 >
|
|
<U4 [1] [SubstrateID_SBS] 1047 >
|
|
<U4 [1] [SubstrateID_EDS1] 1048 >
|
|
<U4 [1] [SubstrateID_EDS2] 1049 >
|
|
<U4 [1] [SubstrateID_CV2] 1050 >
|
|
<U4 [1] [LocationId_CV1] 1051 >
|
|
<U4 [1] [LocationId_SBS] 1052 >
|
|
<U4 [1] [LocationId_EDS1] 1053 >
|
|
<U4 [1] [LocationId_EDS2] 1054 >
|
|
<U4 [1] [LocationId_CV2] 1055 >
|
|
<U4 [1] [Slot1_CV1] 1056 >
|
|
<U4 [1] [Slot1_SBS] 1057 >
|
|
<U4 [1] [Slot1_EDS1] 1058 >
|
|
<U4 [1] [Slot1_EDS2] 1059 >
|
|
<U4 [1] [Slot1_CV2] 1060 >
|
|
<U4 [1] [Target_A_1] 1061 >
|
|
<U4 [1] [Target_A_2] 1062 >
|
|
<U4 [1] [Target_A_3] 1063 >
|
|
<U4 [1] [Target_A_4] 1064 >
|
|
<U4 [1] [Target_A_5] 1065 >
|
|
<U4 [1] [Target_B_1] 1066 >
|
|
<U4 [1] [Target_B_2] 1067 >
|
|
<U4 [1] [Target_B_3] 1068 >
|
|
<U4 [1] [Target_B_4] 1069 >
|
|
<U4 [1] [Target_B_5] 1070 >
|
|
<U4 [1] [Target_C_1] 1071 >
|
|
<U4 [1] [Target_C_2] 1072 >
|
|
<U4 [1] [Target_C_3] 1073 >
|
|
<U4 [1] [Target_C_4] 1074 >
|
|
<U4 [1] [Target_C_5] 1075 >
|
|
<U4 [1] [Target_D_1] 1076 >
|
|
<U4 [1] [Target_D_2] 1077 >
|
|
<U4 [1] [Target_D_3] 1078 >
|
|
<U4 [1] [Target_D_4] 1079 >
|
|
<U4 [1] [Target_D_5] 1080 >
|
|
<U4 [1] [Reroute_A_1] 1081 >
|
|
<U4 [1] [Reroute_A_2] 1082 >
|
|
<U4 [1] [Reroute_A_3] 1083 >
|
|
<U4 [1] [Reroute_A_4] 1084 >
|
|
<U4 [1] [Reroute_A_5] 1085 >
|
|
<U4 [1] [Reroute_B_1] 1086 >
|
|
<U4 [1] [Reroute_B_2] 1087 >
|
|
<U4 [1] [Reroute_B_3] 1088 >
|
|
<U4 [1] [Reroute_B_4] 1089 >
|
|
<U4 [1] [Reroute_B_5] 1090 >
|
|
<U4 [1] [Reroute_C_1] 1091 >
|
|
<U4 [1] [Reroute_C_2] 1092 >
|
|
<U4 [1] [Reroute_C_3] 1093 >
|
|
<U4 [1] [Reroute_C_4] 1094 >
|
|
<U4 [1] [Reroute_C_5] 1095 >
|
|
<U4 [1] [Reroute_D_1] 1096 >
|
|
<U4 [1] [Reroute_D_2] 1097 >
|
|
<U4 [1] [Reroute_D_3] 1098 >
|
|
<U4 [1] [Reroute_D_4] 1099 >
|
|
<U4 [1] [Reroute_D_5] 1100 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200041 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200042 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200052 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200055 >
|
|
<L [2]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [PPChangeName] 1011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200061 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:49,967 [RECV] S2F34 System Bytes=95
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:50,496 [SEND] S2F35 W System Bytes=96
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [CEID] 1 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 2 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 2 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 3 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 3 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 11 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 11 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 12 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 12 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 21 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 21 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 22 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 22 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 23 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 23 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300011 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300012 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200012 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300013 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300021 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200021 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300022 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200022 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300032 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200032 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300041 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200041 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300042 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200042 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300052 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200052 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300055 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200055 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300061 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200061 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:50,526 [RECV] S2F36 System Bytes=96
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:51,057 [SEND] S2F37 W System Bytes=97
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] T >
|
|
<L [19]
|
|
<U4 [1] [EquipmentOffline] 1 >
|
|
<U4 [1] [ControlStateLocal] 2 >
|
|
<U4 [1] [ControlStateRemote] 3 >
|
|
<U4 [1] [AlarmDetected] 11 >
|
|
<U4 [1] [AlarmCleared] 12 >
|
|
<U4 [1] [SpoolTransmitFailure] 21 >
|
|
<U4 [1] [SpoolingActivated] 22 >
|
|
<U4 [1] [SpoolingDeactivated] 23 >
|
|
<U4 [1] [Material_Received] 300011 >
|
|
<U4 [1] [Material_Removed] 300012 >
|
|
<U4 [1] [Material_Hold] 300013 >
|
|
<U4 [1] [Process_Start] 300021 >
|
|
<U4 [1] [Process_Finish] 300022 >
|
|
<U4 [1] [Slotlist] 300032 >
|
|
<U4 [1] [UserLoggedOn] 300041 >
|
|
<U4 [1] [UserLoggedOff] 300042 >
|
|
<U4 [1] [ProcessRecipeSelected] 300052 >
|
|
<U4 [1] [ProcessProgramChange] 300055 >
|
|
<U4 [1] [EquipmentStateChange] 300061 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:51,087 [RECV] S2F38 System Bytes=97
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:12:51,615 [SEND] S5F3 W System Bytes=98
|
|
<L [2]
|
|
<B [1] [ALED] '' 80 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:51,630 [RECV] S5F4 System Bytes=98
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:12:52,159 [SEND] S2F43 W System Bytes=99
|
|
<L [2]
|
|
<L [2]
|
|
<U1 [1] [STRID] 5 >
|
|
<L [1]
|
|
<U1 [1] [] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U1 [1] [STRID] 6 >
|
|
<L [1]
|
|
<U1 [1] [] 11 >
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:52,174 [RECV] S2F44 System Bytes=99
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:52,704 [SEND] S1F3 W System Bytes=100
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:12:52,719 [RECV] S1F4 System Bytes=100
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:10:02.264Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:05,123 [SEND] S1F13 W System Bytes=102
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:05,130 [RECV] S1F13 W System Bytes=492
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:05,136 [SEND] S1F14 System Bytes=492
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:05,392 [RECV] S1F14 System Bytes=102
|
|
<L [2]
|
|
<B [1] [COMMACK] '' 00 >
|
|
<L [2]
|
|
<A [6] [] 'EQPTST' >
|
|
<A [6] [] 'V1.0.0' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:05,923 [SEND] S1F17 W System Bytes=103
|
|
|
|
2023-01-10 11:13:05,939 [RECV] S1F18 System Bytes=103
|
|
<B [1] [] '' 02 >
|
|
.
|
|
|
|
2023-01-10 11:13:06,463 [SEND] S1F3 W System Bytes=104
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:06,478 [RECV] S1F4 System Bytes=104
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:10:16.023Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:07,011 [SEND] S6F23 W System Bytes=105
|
|
<U1 [1] [RSDC] 0 >
|
|
.
|
|
|
|
2023-01-10 11:13:07,027 [RECV] S6F24 System Bytes=105
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:07,087 [RECV] S6F11 W System Bytes=493
|
|
<L [3]
|
|
<U4 [1] [] 65 >
|
|
<U4 [1] [] 22 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 22 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:10:03.015Z' >
|
|
<U1 [1] [] 1 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<A [24] [] '2023-01-10T03:09:56.738Z' >
|
|
<A [24] [] '2023-01-10T03:09:56.738Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:07,102 [SEND] S6F12 W System Bytes=493
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:07,117 [RECV] S6F11 W System Bytes=494
|
|
<L [3]
|
|
<U4 [1] [] 66 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:10:16.663Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:09:56.738Z' >
|
|
<A [24] [] '2023-01-10T03:10:03.014Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:07,132 [SEND] S6F12 W System Bytes=494
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:07,140 [SEND] S2F43 W System Bytes=106
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:07,192 [RECV] S6F11 W System Bytes=495
|
|
<L [3]
|
|
<U4 [1] [] 67 >
|
|
<U4 [1] [] 23 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 23 >
|
|
<L [6]
|
|
<A [24] [] '2023-01-10T03:10:16.737Z' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 1 >
|
|
<U4 [1] [] 1 >
|
|
<A [24] [] '2023-01-10T03:09:56.738Z' >
|
|
<A [24] [] '2023-01-10T03:10:03.014Z' >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:07,207 [SEND] S6F12 W System Bytes=495
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:07,222 [RECV] S2F44 System Bytes=106
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:07,752 [SEND] S2F37 W System Bytes=107
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] F >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:07,767 [RECV] S2F38 System Bytes=107
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:08,296 [SEND] S2F35 W System Bytes=108
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:08,311 [RECV] S2F36 System Bytes=108
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:08,842 [SEND] S2F33 W System Bytes=109
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:08,857 [RECV] S2F34 System Bytes=109
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:09,389 [SEND] S5F3 W System Bytes=110
|
|
<L [2]
|
|
<B [1] [ALED] '' 00 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:09,404 [RECV] S5F4 System Bytes=110
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:13:09,938 [SEND] S2F33 W System Bytes=111
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [reportid] 1 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 2 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 3 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 11 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 12 >
|
|
<L [4]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [AlarmID] 5 >
|
|
<U4 [1] [AlarmText] 6 >
|
|
<U4 [1] [AlarmsCategory] 7 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 21 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 22 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 23 >
|
|
<L [6]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
<U4 [1] [SpoolFullTime] 47 >
|
|
<U4 [1] [SpoolStartTime] 48 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200011 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200012 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200013 >
|
|
<L [12]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [LocationID] 1010 >
|
|
<U4 [1] [MaterialStatus] 1001 >
|
|
<U4 [1] [Target A] 1002 >
|
|
<U4 [1] [Target B] 1003 >
|
|
<U4 [1] [Target C] 1004 >
|
|
<U4 [1] [Target D] 1005 >
|
|
<U4 [1] [Reroute A] 1006 >
|
|
<U4 [1] [Reroute B] 1007 >
|
|
<U4 [1] [Reroute C] 1008 >
|
|
<U4 [1] [Reroute D] 1009 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200021 >
|
|
<L [5]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200022 >
|
|
<L [16]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [ProcessResult] 1013 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [ProcessDurationSBS] 1015 >
|
|
<U4 [1] [ProcessDurationEDS] 1016 >
|
|
<U4 [1] [ProcessRecipeId] 1017 >
|
|
<U4 [1] [ProcessRecipeName] 1018 >
|
|
<U4 [1] [ProcessRecipeVersion] 1019 >
|
|
<U4 [1] [ProcessRecipeCreationDate] 1020 >
|
|
<U4 [1] [ProcessRecipeLastModificationDate] 1021 >
|
|
<U4 [1] [ProcessRecipeCreatedBy] 1022 >
|
|
<U4 [1] [ProcessRecipeLastModifiedBy] 1023 >
|
|
<U4 [1] [MeasuredSubstrateWidth] 1024 >
|
|
<U4 [1] [MeasuredSubstrateLength] 1025 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200032 >
|
|
<L [56]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID_CV1] 1046 >
|
|
<U4 [1] [SubstrateID_SBS] 1047 >
|
|
<U4 [1] [SubstrateID_EDS1] 1048 >
|
|
<U4 [1] [SubstrateID_EDS2] 1049 >
|
|
<U4 [1] [SubstrateID_CV2] 1050 >
|
|
<U4 [1] [LocationId_CV1] 1051 >
|
|
<U4 [1] [LocationId_SBS] 1052 >
|
|
<U4 [1] [LocationId_EDS1] 1053 >
|
|
<U4 [1] [LocationId_EDS2] 1054 >
|
|
<U4 [1] [LocationId_CV2] 1055 >
|
|
<U4 [1] [Slot1_CV1] 1056 >
|
|
<U4 [1] [Slot1_SBS] 1057 >
|
|
<U4 [1] [Slot1_EDS1] 1058 >
|
|
<U4 [1] [Slot1_EDS2] 1059 >
|
|
<U4 [1] [Slot1_CV2] 1060 >
|
|
<U4 [1] [Target_A_1] 1061 >
|
|
<U4 [1] [Target_A_2] 1062 >
|
|
<U4 [1] [Target_A_3] 1063 >
|
|
<U4 [1] [Target_A_4] 1064 >
|
|
<U4 [1] [Target_A_5] 1065 >
|
|
<U4 [1] [Target_B_1] 1066 >
|
|
<U4 [1] [Target_B_2] 1067 >
|
|
<U4 [1] [Target_B_3] 1068 >
|
|
<U4 [1] [Target_B_4] 1069 >
|
|
<U4 [1] [Target_B_5] 1070 >
|
|
<U4 [1] [Target_C_1] 1071 >
|
|
<U4 [1] [Target_C_2] 1072 >
|
|
<U4 [1] [Target_C_3] 1073 >
|
|
<U4 [1] [Target_C_4] 1074 >
|
|
<U4 [1] [Target_C_5] 1075 >
|
|
<U4 [1] [Target_D_1] 1076 >
|
|
<U4 [1] [Target_D_2] 1077 >
|
|
<U4 [1] [Target_D_3] 1078 >
|
|
<U4 [1] [Target_D_4] 1079 >
|
|
<U4 [1] [Target_D_5] 1080 >
|
|
<U4 [1] [Reroute_A_1] 1081 >
|
|
<U4 [1] [Reroute_A_2] 1082 >
|
|
<U4 [1] [Reroute_A_3] 1083 >
|
|
<U4 [1] [Reroute_A_4] 1084 >
|
|
<U4 [1] [Reroute_A_5] 1085 >
|
|
<U4 [1] [Reroute_B_1] 1086 >
|
|
<U4 [1] [Reroute_B_2] 1087 >
|
|
<U4 [1] [Reroute_B_3] 1088 >
|
|
<U4 [1] [Reroute_B_4] 1089 >
|
|
<U4 [1] [Reroute_B_5] 1090 >
|
|
<U4 [1] [Reroute_C_1] 1091 >
|
|
<U4 [1] [Reroute_C_2] 1092 >
|
|
<U4 [1] [Reroute_C_3] 1093 >
|
|
<U4 [1] [Reroute_C_4] 1094 >
|
|
<U4 [1] [Reroute_C_5] 1095 >
|
|
<U4 [1] [Reroute_D_1] 1096 >
|
|
<U4 [1] [Reroute_D_2] 1097 >
|
|
<U4 [1] [Reroute_D_3] 1098 >
|
|
<U4 [1] [Reroute_D_4] 1099 >
|
|
<U4 [1] [Reroute_D_5] 1100 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200041 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200042 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [UserName] 21012 >
|
|
<U4 [1] [PreviousUserName] 21013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200052 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [SubstrateID] 1000 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200055 >
|
|
<L [2]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [PPChangeName] 1011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [reportid] 200061 >
|
|
<L [3]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:09,954 [RECV] S2F34 System Bytes=111
|
|
<B [1] [DRACK] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:10,487 [SEND] S2F35 W System Bytes=112
|
|
<L [2]
|
|
<U4 [1] [DATAID] 0 >
|
|
<L [19]
|
|
<L [2]
|
|
<U4 [1] [CEID] 1 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 2 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 2 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 3 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 3 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 11 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 11 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 12 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 12 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 21 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 21 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 22 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 22 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 23 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 23 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300011 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200011 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300012 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200012 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300013 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200013 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300021 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200021 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300022 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200022 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300032 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200032 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300041 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200041 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300042 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200042 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300052 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200052 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300055 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200055 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U4 [1] [CEID] 300061 >
|
|
<L [1]
|
|
<U4 [1] [RPTID] 200061 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:10,502 [RECV] S2F36 System Bytes=112
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:11,033 [SEND] S2F37 W System Bytes=113
|
|
<L [2]
|
|
<BOOLEAN [1] [CEED] T >
|
|
<L [19]
|
|
<U4 [1] [EquipmentOffline] 1 >
|
|
<U4 [1] [ControlStateLocal] 2 >
|
|
<U4 [1] [ControlStateRemote] 3 >
|
|
<U4 [1] [AlarmDetected] 11 >
|
|
<U4 [1] [AlarmCleared] 12 >
|
|
<U4 [1] [SpoolTransmitFailure] 21 >
|
|
<U4 [1] [SpoolingActivated] 22 >
|
|
<U4 [1] [SpoolingDeactivated] 23 >
|
|
<U4 [1] [Material_Received] 300011 >
|
|
<U4 [1] [Material_Removed] 300012 >
|
|
<U4 [1] [Material_Hold] 300013 >
|
|
<U4 [1] [Process_Start] 300021 >
|
|
<U4 [1] [Process_Finish] 300022 >
|
|
<U4 [1] [Slotlist] 300032 >
|
|
<U4 [1] [UserLoggedOn] 300041 >
|
|
<U4 [1] [UserLoggedOff] 300042 >
|
|
<U4 [1] [ProcessRecipeSelected] 300052 >
|
|
<U4 [1] [ProcessProgramChange] 300055 >
|
|
<U4 [1] [EquipmentStateChange] 300061 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:11,063 [RECV] S2F38 System Bytes=113
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:11,588 [SEND] S5F3 W System Bytes=114
|
|
<L [2]
|
|
<B [1] [ALED] '' 80 >
|
|
<U4 [1] [ALID] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:11,603 [RECV] S5F4 System Bytes=114
|
|
<B [1] [ACKC5] '' 01 >
|
|
.
|
|
|
|
2023-01-10 11:13:12,132 [SEND] S2F43 W System Bytes=115
|
|
<L [2]
|
|
<L [2]
|
|
<U1 [1] [STRID] 5 >
|
|
<L [1]
|
|
<U1 [1] [] 1 >
|
|
>
|
|
>
|
|
<L [2]
|
|
<U1 [1] [STRID] 6 >
|
|
<L [1]
|
|
<U1 [1] [] 11 >
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:12,147 [RECV] S2F44 System Bytes=115
|
|
<L [2]
|
|
<B [1] [] '' 00 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:12,675 [SEND] S1F3 W System Bytes=116
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:12,690 [RECV] S1F4 System Bytes=116
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:10:22.234Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:13,223 [SEND] S5F5 W System Bytes=117
|
|
<L [0]
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:13,255 [RECV] S5F6 System Bytes=117
|
|
<L [135]
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4065 >
|
|
<A [31] [] 'CV2: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4067 >
|
|
<A [29] [] 'CV2: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4066 >
|
|
<A [29] [] 'CV2: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4069 >
|
|
<A [40] [] 'CV2: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4068 >
|
|
<A [30] [] 'CV2: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4070 >
|
|
<A [20] [] 'CV2: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4073 >
|
|
<A [21] [] 'CV2: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3004 >
|
|
<A [36] [] 'EDS: Estop left infeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3005 >
|
|
<A [38] [] 'EDS: Estop right infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3006 >
|
|
<A [39] [] 'EDS: Estop right outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3007 >
|
|
<A [40] [] 'EDS: Estop right infeed inside activexxx' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3001 >
|
|
<A [25] [] 'EDS: Estop cabinet active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3002 >
|
|
<A [37] [] 'EDS: Estop left infeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4086 >
|
|
<A [25] [] 'CV2: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3003 >
|
|
<A [38] [] 'EDS: Estop left outfeed outside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3049 >
|
|
<A [38] [] 'EDS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4005 >
|
|
<A [43] [] 'CV2: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3048 >
|
|
<A [40] [] 'EDS: Safety fault feedback Estop circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4004 >
|
|
<A [25] [] 'CV2: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3051 >
|
|
<A [22] [] 'EDS: Error door left 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3050 >
|
|
<A [40] [] 'EDS: Safety fault feedback laser circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 4006 >
|
|
<A [31] [] 'CV2: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3053 >
|
|
<A [22] [] 'EDS: Error door left 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4001 >
|
|
<A [22] [] 'CV2: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3052 >
|
|
<A [22] [] 'EDS: Error door left 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3055 >
|
|
<A [23] [] 'EDS: Error door right 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4003 >
|
|
<A [38] [] 'CV2: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3054 >
|
|
<A [22] [] 'EDS: Error door left 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4002 >
|
|
<A [23] [] 'CV2: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3041 >
|
|
<A [18] [] 'EDS: Error chiller' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3040 >
|
|
<A [28] [] 'EDS: time out vacuum outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3043 >
|
|
<A [26] [] 'EDS: Error aspiration unit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3042 >
|
|
<A [23] [] 'EDS: Error Flap outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3045 >
|
|
<A [29] [] 'EDS: Error drive align infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3044 >
|
|
<A [22] [] 'EDS: Error flap infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3047 >
|
|
<A [32] [] 'EDS: Error drive conveyor infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3046 >
|
|
<A [30] [] 'EDS: Error drive align outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 4010 >
|
|
<A [22] [] 'CV2: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3064 >
|
|
<A [60] [] 'EDS: laser commisiioning active // automatik mode prohibited' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3065 >
|
|
<A [42] [] 'EDS: Interface downstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3066 >
|
|
<A [40] [] 'EDS: Interface upstream life signal lost' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3067 >
|
|
<A [31] [] 'EDS: Interface downstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3068 >
|
|
<A [29] [] 'EDS: Interface upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3069 >
|
|
<A [41] [] 'EDS: gap sensor not free / transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3070 >
|
|
<A [20] [] 'EDS: HMI-PLC Timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3071 >
|
|
<A [33] [] 'EDS: Aligning axis not referenced' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3056 >
|
|
<A [23] [] 'EDS: Error door right 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3057 >
|
|
<A [23] [] 'EDS: Error door right 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3058 >
|
|
<A [23] [] 'EDS: Error door right 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3062 >
|
|
<A [33] [] 'EDS: Error drive conveyor outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3063 >
|
|
<A [50] [] 'EDS: Gripper free with data / glass not in gripper' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3019 >
|
|
<A [23] [] 'EDS: time out gripper 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1066 >
|
|
<A [29] [] 'CV1: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3018 >
|
|
<A [23] [] 'EDS: time out gripper 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1067 >
|
|
<A [29] [] 'CV1: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3017 >
|
|
<A [31] [] 'EDS: time out gripper Aligning2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3016 >
|
|
<A [31] [] 'EDS: time out gripper Aligning1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1065 >
|
|
<A [31] [] 'CV1: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3023 >
|
|
<A [30] [] 'EDS: time out gripper linear 1' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1070 >
|
|
<A [20] [] 'CV1: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3022 >
|
|
<A [23] [] 'EDS: time out gripper 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3021 >
|
|
<A [23] [] 'EDS: time out gripper 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1068 >
|
|
<A [30] [] 'CV1: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3020 >
|
|
<A [21] [] 'EDS: Fuse chiller NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1069 >
|
|
<A [40] [] 'CV1: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3011 >
|
|
<A [16] [] 'EDS: Laser error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3010 >
|
|
<A [31] [] 'EDS: Estop extern active active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3009 >
|
|
<A [41] [] 'EDS: Estop right outfeed inside activeyyy' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 3008 >
|
|
<A [37] [] 'EDS: Estop left outfeed inside active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3015 >
|
|
<A [29] [] 'EDS: Fuse cabinet cooling NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3501 >
|
|
<A [42] [] 'EDS: Automatic power measurement requested' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3014 >
|
|
<A [31] [] 'EDS: Overvoltage protection NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3013 >
|
|
<A [33] [] 'EDS: Communication with Laser NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3012 >
|
|
<A [34] [] 'EDS: Fuse Power supply Laser 1 NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3034 >
|
|
<A [37] [] 'EDS: time out conveyor lifting infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3035 >
|
|
<A [38] [] 'EDS: time out conveyor lifting outfeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3505 >
|
|
<A [52] [] 'EDS: Laser simulation mode active. No laser emission' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3032 >
|
|
<A [28] [] 'EDS: Fuse 24V peripheral NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 06 >
|
|
<U4 [1] [] 3506 >
|
|
<A [53] [] 'EDS: Aspiration settings too low. Beware of pollution' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3033 >
|
|
<A [23] [] 'EDS: Fuse 24V drive NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3038 >
|
|
<A [28] [] 'EDS: process stopped by user' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3039 >
|
|
<A [27] [] 'EDS: time out vacuum infeed' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1086 >
|
|
<A [25] [] 'CV1: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3036 >
|
|
<A [30] [] 'EDS: time out gripper ref glas' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3037 >
|
|
<A [36] [] 'EDS: error air pressure out of range' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3026 >
|
|
<A [30] [] 'EDS: time out gripper linear 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3027 >
|
|
<A [34] [] 'EDS: Fuse 24V Operator buttons NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3024 >
|
|
<A [30] [] 'EDS: air conditioning CA fault' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1073 >
|
|
<A [21] [] 'CV1: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3025 >
|
|
<A [30] [] 'EDS: time out gripper linear 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3030 >
|
|
<A [30] [] 'EDS: time out gripper linear 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3031 >
|
|
<A [31] [] 'EDS: Fuse 24V miscellaneous NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3028 >
|
|
<A [24] [] 'EDS: Fuse supply Asi NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3029 >
|
|
<A [21] [] 'EDS: Fuse 24V IPC NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2065 >
|
|
<A [31] [] 'SBS: Downstream life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2067 >
|
|
<A [29] [] 'SBS: Interface Upstream error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2066 >
|
|
<A [29] [] 'SBS: Upstream Life signal NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2069 >
|
|
<A [40] [] 'SBS: Gap sensor not free. Transfer error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2068 >
|
|
<A [30] [] 'SBS: Interface downstream erro' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2070 >
|
|
<A [20] [] 'SBS: HMI-PLC timeout' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2073 >
|
|
<A [21] [] 'SBS: Sequence stopped' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2017 >
|
|
<A [19] [] 'SBS: Error lift low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2016 >
|
|
<A [27] [] 'SBS: Error single centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2019 >
|
|
<A [17] [] 'SBS: Error vacuum' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2018 >
|
|
<A [18] [] 'SBS: Error lift up' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2002 >
|
|
<A [23] [] 'SBS: Estop right active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2003 >
|
|
<A [38] [] 'SBS: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 2001 >
|
|
<A [22] [] 'SBS: Estop Left active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2006 >
|
|
<A [18] [] 'SBS: Error Brush 2' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2007 >
|
|
<A [18] [] 'SBS: Error Brush 3' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2004 >
|
|
<A [25] [] 'SBS: Error conveyor drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2005 >
|
|
<A [19] [] 'SBS: Error Brush 1 ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2010 >
|
|
<A [22] [] 'SBS: Estop line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2008 >
|
|
<A [18] [] 'SBS: Error Brush 4' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2009 >
|
|
<A [35] [] 'SBS: Error brush 1 linear movement ' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2014 >
|
|
<A [34] [] 'SBS: Error brush 4 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2015 >
|
|
<A [25] [] 'SBS: Error dual centering' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2012 >
|
|
<A [34] [] 'SBS: Error brush 2 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2013 >
|
|
<A [34] [] 'SBS: Error brush 3 linear movement' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 2086 >
|
|
<A [25] [] 'SBS: Timeout infeed error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1010 >
|
|
<A [22] [] 'CV1: Estop Line active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1001 >
|
|
<A [22] [] 'CV1: Estop Left Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1003 >
|
|
<A [38] [] 'CV1: Safety fault feedback STO circuit' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 02 >
|
|
<U4 [1] [] 1002 >
|
|
<A [23] [] 'CV1: EStop Right Active' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1005 >
|
|
<A [43] [] 'CV1: Data on positon without sensor signals' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1004 >
|
|
<A [25] [] 'CV1: Error Conveyor Drive' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 1006 >
|
|
<A [31] [] 'CV1: Glass present without data' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3072 >
|
|
<A [32] [] 'EDS: Fuse Drives 400V supply NOK' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3073 >
|
|
<A [38] [] 'EDS: SQ stopped by HMI => no PLC error' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3074 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 1 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3075 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 2 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3076 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 3 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3077 >
|
|
<A [40] [] 'EDS: Cooling water flow circuit 4 to low' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3078 >
|
|
<A [45] [] 'EDS: Aspiration flow ASP too low (upper head)' >
|
|
>
|
|
<L [3]
|
|
<B [1] [] '' 05 >
|
|
<U4 [1] [] 3079 >
|
|
<A [45] [] 'EDS: Aspiration flow PHD too low (lower head)' >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:13,784 [SEND] S7F19 W System Bytes=118
|
|
|
|
2023-01-10 11:13:13,799 [RECV] S7F20 System Bytes=118
|
|
<L [8]
|
|
<A [22] [PPID] 'ProcessRecipe_9.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_7.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_8.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_3.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_1.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_5.recipe' >
|
|
<A [23] [PPID] 'ProcessRecipe_10.recipe' >
|
|
<A [22] [PPID] 'ProcessRecipe_2.recipe' >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:14,329 [SEND] S2F13 W System Bytes=119
|
|
<L [14]
|
|
<U4 [1] [EnableAlarmReportSend] 4 >
|
|
<U4 [1] [TimeFormat] 8 >
|
|
<U4 [1] [MaxTerminalMsgLength] 9 >
|
|
<U4 [1] [EstablishCommunicationsTimeout] 49 >
|
|
<U4 [1] [DefaultCommunicationState] 12 >
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U4 [1] [DefaultOfflineSubState] 17 >
|
|
<U4 [1] [EnableSpooling] 40 >
|
|
<U4 [1] [OverWriteSpool] 42 >
|
|
<U4 [1] [MaxSpoolMessages] 43 >
|
|
<U4 [1] [MaxSpoolTransmit] 44 >
|
|
<U4 [1] [MDLN] 1 >
|
|
<U4 [1] [SOFTREV] 2 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:14,344 [RECV] S2F14 System Bytes=119
|
|
<L [14]
|
|
<BOOLEAN [1] [] T >
|
|
<U1 [1] [] 2 >
|
|
<U4 [1] [] 80 >
|
|
<I2 [1] [] 30 >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 2 >
|
|
<BOOLEAN [1] [] T >
|
|
<BOOLEAN [1] [] T >
|
|
<U4 [1] [] 100000 >
|
|
<U4 [1] [] 0 >
|
|
<L [0]
|
|
>
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:14,875 [SEND] S2F15 W System Bytes=120
|
|
<L [2]
|
|
<L [2]
|
|
<U4 [1] [DefaultControlState] 15 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
<L [2]
|
|
<U4 [1] [DefaultOnlineSubState] 16 >
|
|
<U1 [1] [ECV] 5 >
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:14,890 [RECV] S2F16 System Bytes=120
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:15,423 [SEND] S1F15 W System Bytes=121
|
|
|
|
2023-01-10 11:13:15,438 [RECV] S1F16 System Bytes=121
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:15,444 [RECV] S6F11 W System Bytes=496
|
|
<L [3]
|
|
<U4 [1] [] 68 >
|
|
<U4 [1] [] 1 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 1 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:10:24.982Z' >
|
|
<U1 [1] [] 3 >
|
|
<U1 [1] [] 5 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:15,446 [SEND] S6F12 W System Bytes=496
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:15,967 [SEND] S1F17 W System Bytes=122
|
|
|
|
2023-01-10 11:13:15,983 [RECV] S6F11 W System Bytes=497
|
|
<L [3]
|
|
<U4 [1] [] 69 >
|
|
<U4 [1] [] 3 >
|
|
<L [1]
|
|
<L [2]
|
|
<U4 [1] [] 3 >
|
|
<L [3]
|
|
<A [24] [] '2023-01-10T03:10:25.528Z' >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
>
|
|
>
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:15,983 [RECV] S1F18 System Bytes=122
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:15,991 [SEND] S6F12 W System Bytes=497
|
|
<B [1] [ACKC6] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:16,527 [SEND] S1F3 W System Bytes=123
|
|
<L [10]
|
|
<U4 [1] [Clock] 3 >
|
|
<U4 [1] [CommunicationState] 11 >
|
|
<U4 [1] [CurrentControlState] 13 >
|
|
<U4 [1] [PreviousControlState] 14 >
|
|
<U4 [1] [CurrentEquipmentState] 21010 >
|
|
<U4 [1] [PreviousEquipmentState] 21011 >
|
|
<U4 [1] [PPExecName] 72 >
|
|
<U4 [1] [SpoolingState] 41 >
|
|
<U4 [1] [SpoolCountActual] 45 >
|
|
<U4 [1] [SpoolCountTotal] 46 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:16,542 [RECV] S1F4 System Bytes=123
|
|
<L [10]
|
|
<A [24] [SVID] '2023-01-10T03:10:26.086Z' >
|
|
<U1 [1] [] 1 >
|
|
<U1 [1] [] 5 >
|
|
<U1 [1] [] 3 >
|
|
<I2 [1] [] 2000 >
|
|
<I2 [1] [] 1000 >
|
|
<A [0] [] '' >
|
|
<U1 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
<U4 [1] [] 0 >
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:17,068 [SEND] S2F23 W System Bytes=124
|
|
<L [5]
|
|
<U4 [1] [TRID] 1 >
|
|
<A [6] [DSPER_hhmmss] '000010' >
|
|
<U4 [1] [TOTSMP] 0 >
|
|
<U4 [1] [REPGSZ] 1 >
|
|
<L [0]
|
|
>
|
|
>
|
|
.
|
|
|
|
2023-01-10 11:13:17,083 [RECV] S2F24 System Bytes=124
|
|
<B [1] [] '' 00 >
|
|
.
|
|
|
|
2023-01-10 11:13:38,600 T3 Timeout: System Bytes=101
|